2. Product Core Brief
- Model: CI854BK01
- Brand: ABB
- Series: AC 800M / System 800xA
- Core Function: PROFIBUS DP/V1 communication
- Product Type: Communication Interface Module
- Key Specs: Dual ports | 9.6 kbit/s to 12 Mbit/s | Line & master redundancy
- Condition: New Surplus (original OEM manufacturing, QC tested, anti-static packaged)
- Inventory Status: Active spare—strategic buffer recommended as 800xA ecosystems mature and lead times fluctuate
3. Key Technical Specifications
- Article number: 3BSE069449R1 (CI854BK01)
- Communication protocol: PROFIBUS DP-V1 (Master)
- Number of channels/ports: 2 (for line redundancy)
- Transmission speed: 9.6 kbit/s to 12 Mbit/s
- Line redundancy: Yes
- Module redundancy: Yes (PROFIBUS master redundancy supported)
- Hot swap: Yes
- Connector: DB female (9-pin)
- Power consumption: 24 V DC typ. 190 mA
- Operating temperature: 0 to +55 °C (+32 to +131 °F)
- Storage temperature: -40 to +70 °C (-40 to +158 °F)
- Dimensions (approx.): Width 59 mm (2.3 in) | Height 185 mm (7.3 in) | Depth 127.5 mm (5.0 in)
- Weight (including TP854 baseplate): 700 g (1.5 lbs)
- Mounting: AC 800M CEX bus (package includes CI854 interface + TP854 baseplate)
- Certifications: CE, marine (ABS, BV, DNV-GL, LR), RoHS compliant
- CI854BK01 3BSE069449R1
4. Product Introduction & Supply Chain Strategy The ABB CI854BK01 (3BSE069449R1) PROFIBUS-DP/V1 interface module links AC 800M controllers to PROFIBUS field networks. Dual ports enable line redundancy, while master redundancy support ensures high availability for interconnecting remote I/O, drives, actuators, and instrumentation in demanding process control applications.
New Surplus procurement maintains 800xA reliability cost-effectively. With variable lead times on communication interfaces, a failed CI854BK01 can sever PROFIBUS segments and halt loops or safety functions. Genuine New Surplus avoids refurbished pitfalls like degraded ports or unreliable protocol handling that cause intermittent faults and extended troubleshooting. Keep 1-2 units on-hand as buffer stock to reduce outage exposure, minimize total cost of ownership versus refurbished uncertainty or prolonged OEM sourcing, and preserve uptime in mature AC 800M deployments.
5. Installation & Configuration Guide Stage 1: Pre-Installation (Prep & Safety) Lock out/tag out the AC 800M controller rack power. Discharge any stored energy. Wear grounded ESD wrist strap. Photograph existing module: orientation, PROFIBUS cable connections (ports A/B), baseplate setup, any labeling, and CEX bus position. Verify tools: ESD-safe screwdriver, torque driver, multimeter for continuity/insulation.
Stage 2: Removal Power down the controller. Confirm zero voltage on CEX bus and ports. Disconnect PROFIBUS cables carefully (note port assignments). Loosen mounting on TP854 baseplate if needed. Extract module/baseplate assembly straight—avoid stressing CEX pins or connectors. Inspect contacts and baseplate for wear. Bag removed unit ESD-safe.
Stage 3: Installation (Clone & Seat) Seat new CI854BK01 + TP854 baseplate fully into the CEX bus—ensure alignment and secure engagement. Reconnect PROFIBUS cables exactly as photographed (match A/B ports for redundancy). Torque connections per ABB spec (typically 0.5-0.6 Nm for terminals). Verify termination resistors if required (plug must be powered for correct termination).
Stage 4: Power-On & Testing Apply power step-by-step. Monitor module LEDs for status (power, run, no faults). Use 800xA Control Builder or engineering station to verify configuration and download if needed. Check PROFIBUS diagnostics (bus status, device polling, redundancy health). Confirm communication with field devices, no errors in handshake or data exchange, and run functional tests before full process resumption.
6. Firmware/Software Versions & Upgrade Notes The CI854BK01 has no user-upgradable onboard firmware—PROFIBUS protocol handling is embedded hardware/firmware. Configuration and diagnostics are managed via System 800xA Control Builder or AC 800M engineering tools. No direct firmware version applies to the module.
Compatibility note: Fully compatible in AC 800M racks (including HI controllers) and 800xA versions supporting CI854B family. Document existing controller firmware and PROFIBUS network config before swap. Controller or 800xA software upgrades during replacement can affect bus timing or diagnostics—always backup configs, test in engineering mode, and validate network health post-install.
7. Frequently Asked Questions (FAQ) Is this really new and not refurbished? Yes—this is New Surplus from authorized channels: original ABB production, opened only for QC (visual/electrical), zero hours in service, no repairs or rework. We exclude refurbished or field-pulled units.
Why choose New Surplus over refurbished when it’s higher priced? Refurbished undercuts short-term but risks port wear, signal degradation, or protocol faults that disrupt PROFIBUS networks and cause process interruptions—downtime multiplies savings many times. New Surplus provides reliable redundancy and speed at below current OEM list, with less exposure than variable lead times.
Is the CI854BK01 obsolete or facing supply constraints? AC 800M and PROFIBUS interfaces stay supported in 800xA, but module availability varies with demand. Strategic stocking of 1-2 New Surplus units protects against delays without forcing migrations.
Can this PROFIBUS interface be hot-swapped? Yes—hot swap supported in AC 800M (with redundancy configured). For non-redundant setups, power down the rack, discharge, and lock out to prevent bus disruption or safety risks. Follow ABB guidelines.
Does the module retain any configuration? No—configuration (network addresses, baud rate, device mapping) loads from the AC 800M controller via engineering tools. Backup/export config before removal, then reload to the new module. Photos assist cable/port verification.




WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626