Description
Core Product Summary
The Toshiba PF612 is a PROFIBUS-DP slave module designed for the Integrated Controller V Series model 2000 (S2T/S2E) and Unified Controller nv series type1 light systems. It provides cyclic process data communication over a PROFIBUS-DP network.
The module mounts on the G2 I/O bus, occupies one slot, and supports input and output data sizes of up to 244 bytes each. It operates at transmission speeds from 9.6 kbit/s to 12 Mbit/s and conforms to EN50170 (DPV0) as a Profibus-DP slave. Parameter setup is performed via module switches or the controller application program.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | PROFIBUS-DP Slave module |
| Compatible systems | Integrated Controller V Series model 2000 (S2T/S2E); nv series type1 light |
| Connection bus | G2 I/O bus |
| Slot occupancy | 1 slot |
| Process data (cyclic) | Input 244 bytes / Output 244 bytes |
| Transmission speed | 9.6 kbit/s to 12 Mbit/s |
| Conforming standard | EN50170 (DPV0) Profibus-DP Slave |
| Current consumption | 1.0 A |
| Operating temperature | 0 to 45 °C |
| Max. stations on network | 122 (32 per segment, expandable with repeaters) |
| Transmission cable | RS-485 shielded twisted pair |
Detailed Product Overview
The Toshiba PF612 is a dedicated communication module that adds PROFIBUS-DP slave capability to compatible Toshiba controllers. It connects to the controller via the G2 I/O bus and occupies a single slot in the base unit.
Once installed, the module allows cyclic process data transfer of up to 244 bytes in each direction. Transmission parameters and data lengths can be set either by switches on the module itself or by instructions executed in the controller application program. Supported baud rates range from 9.6 kbit/s to 12 Mbit/s, covering the full PROFIBUS-DP speed spectrum defined by EN50170 (DPV0).
The physical layer uses optically isolated RS-485 and requires standard shielded twisted-pair PROFIBUS cable with proper network termination. Up to 122 stations can participate on a single PROFIBUS network when repeaters are used (maximum 32 stations per segment).
Current consumption is 1.0 A. The module is rated for ambient temperatures of 0 to 45 °C; forced-air cooling is recommended when the temperature exceeds this range. Status and diagnostic information, including module operating mode and a healthy counter, are available to the controller application for monitoring.
Because the module operates strictly as a slave, a PROFIBUS-DP master must be present on the network. Configuration of the overall PROFIBUS system is performed with the appropriate Toshiba engineering tool (PROSEC T-PDS or nv-Tool). The PF612 (and its A-version counterpart PF612A) is therefore selected when an existing or new Toshiba controller needs to participate as a data-exchange slave on a PROFIBUS-DP fieldbus.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host controller | V Series model 2000 S2T/S2E; nv series type1 light | Module installs in controller base unit |
| Bus interface | G2 I/O bus | Occupies one slot |
| Network role | PROFIBUS-DP Slave | Requires a PROFIBUS-DP master on the network |
| Data size | Up to 244 bytes input / 244 bytes output | Configured by switch or application program |
| Engineering tool | PROSEC T-Series (T-PDS) or corresponding nv-Tool | Required for system configuration |
| Cable | RS-485 shielded twisted pair | Standard PROFIBUS cabling with terminators |
| Module count | Up to 8 total (PF611/PF611A + PF612/PF612A) | System-level limit |

PF612

PF612
Applications & System Role
The Toshiba PF612 functions as a PROFIBUS-DP slave interface within Toshiba Integrated Controller V Series model 2000 and nv series systems. It enables the controller to exchange cyclic process data with a PROFIBUS-DP master or other network devices.
In the automation architecture it sits on the controller’s G2 I/O bus and presents the controller’s process data to the PROFIBUS network. Typical use is remote I/O or inter-controller data exchange where the Toshiba controller operates as a slave node on an existing PROFIBUS-DP network.
Engineering Selection Highlights
- Direct compatibility with Toshiba V Series model 2000 (S2T/S2E) and nv series type1 light controllers via the G2 I/O bus determines system fit.
- Cyclic data capacity of 244 bytes input and 244 bytes output supports process data exchange with a PROFIBUS-DP master.
- Transmission speed range up to 12 Mbit/s allows matching network performance requirements.
- Parameter configuration by module setup switches or controller program provides flexible commissioning options.
- Maximum of eight combined PF611/PF612 (or A-version) modules per system limits total network interface count.
- Ambient temperature rating of 0–45 °C with recommended forced-air cooling above this range affects installation environment selection.
FAQ
What is the Toshiba PF612?
It is a PROFIBUS-DP slave communication module for Toshiba Integrated Controller V Series model 2000 and nv series controllers.
Which systems is the PF612 compatible with?
It is compatible with Integrated Controller V Series model 2000 (S2T/S2E) and Unified Controller nv series type1 light systems via the G2 I/O bus.
What data size does the PF612 support?
It supports cyclic process data of up to 244 bytes input and 244 bytes output.
What transmission speeds are supported?
Transmission speeds range from 9.6 kbit/s to 12 Mbit/s.
How is the module configured?
Parameters are set either by switches on the module or by the controller application program.
What is the operating temperature range?
The module is rated for 0 to 45 °C ambient temperature; forced-air cooling is recommended above this range.