Sale!

Toshiba PF612 PROFIBUS-DP Slave Module

The Toshiba PF612 is a PROFIBUS-DP slave module designed for the Integrated Controller V Series model 2000 (S2T/S2E) and Unified Controller nv series type1 light systems. It provides cyclic process data communication over a PROFIBUS-DP network.

Categories: , , , , SKU: PF612 Brand:

Description

Core Product Summary

The Toshiba PF612 is a PROFIBUS-DP slave module designed for the Integrated Controller V Series model 2000 (S2T/S2E) and Unified Controller nv series type1 light systems. It provides cyclic process data communication over a PROFIBUS-DP network.

The module mounts on the G2 I/O bus, occupies one slot, and supports input and output data sizes of up to 244 bytes each. It operates at transmission speeds from 9.6 kbit/s to 12 Mbit/s and conforms to EN50170 (DPV0) as a Profibus-DP slave. Parameter setup is performed via module switches or the controller application program.

Key Technical Specifications

Parameter Value
Product type PROFIBUS-DP Slave module
Compatible systems Integrated Controller V Series model 2000 (S2T/S2E); nv series type1 light
Connection bus G2 I/O bus
Slot occupancy 1 slot
Process data (cyclic) Input 244 bytes / Output 244 bytes
Transmission speed 9.6 kbit/s to 12 Mbit/s
Conforming standard EN50170 (DPV0) Profibus-DP Slave
Current consumption 1.0 A
Operating temperature 0 to 45 °C
Max. stations on network 122 (32 per segment, expandable with repeaters)
Transmission cable RS-485 shielded twisted pair

Detailed Product Overview

The Toshiba PF612 is a dedicated communication module that adds PROFIBUS-DP slave capability to compatible Toshiba controllers. It connects to the controller via the G2 I/O bus and occupies a single slot in the base unit.

Once installed, the module allows cyclic process data transfer of up to 244 bytes in each direction. Transmission parameters and data lengths can be set either by switches on the module itself or by instructions executed in the controller application program. Supported baud rates range from 9.6 kbit/s to 12 Mbit/s, covering the full PROFIBUS-DP speed spectrum defined by EN50170 (DPV0).

The physical layer uses optically isolated RS-485 and requires standard shielded twisted-pair PROFIBUS cable with proper network termination. Up to 122 stations can participate on a single PROFIBUS network when repeaters are used (maximum 32 stations per segment).

Current consumption is 1.0 A. The module is rated for ambient temperatures of 0 to 45 °C; forced-air cooling is recommended when the temperature exceeds this range. Status and diagnostic information, including module operating mode and a healthy counter, are available to the controller application for monitoring.

Because the module operates strictly as a slave, a PROFIBUS-DP master must be present on the network. Configuration of the overall PROFIBUS system is performed with the appropriate Toshiba engineering tool (PROSEC T-PDS or nv-Tool). The PF612 (and its A-version counterpart PF612A) is therefore selected when an existing or new Toshiba controller needs to participate as a data-exchange slave on a PROFIBUS-DP fieldbus.

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Host controller V Series model 2000 S2T/S2E; nv series type1 light Module installs in controller base unit
Bus interface G2 I/O bus Occupies one slot
Network role PROFIBUS-DP Slave Requires a PROFIBUS-DP master on the network
Data size Up to 244 bytes input / 244 bytes output Configured by switch or application program
Engineering tool PROSEC T-Series (T-PDS) or corresponding nv-Tool Required for system configuration
Cable RS-485 shielded twisted pair Standard PROFIBUS cabling with terminators
Module count Up to 8 total (PF611/PF611A + PF612/PF612A) System-level limit
PF612

PF612

PF612

PF612

Applications & System Role

The Toshiba PF612 functions as a PROFIBUS-DP slave interface within Toshiba Integrated Controller V Series model 2000 and nv series systems. It enables the controller to exchange cyclic process data with a PROFIBUS-DP master or other network devices.

In the automation architecture it sits on the controller’s G2 I/O bus and presents the controller’s process data to the PROFIBUS network. Typical use is remote I/O or inter-controller data exchange where the Toshiba controller operates as a slave node on an existing PROFIBUS-DP network.

Engineering Selection Highlights

  • Direct compatibility with Toshiba V Series model 2000 (S2T/S2E) and nv series type1 light controllers via the G2 I/O bus determines system fit.
  • Cyclic data capacity of 244 bytes input and 244 bytes output supports process data exchange with a PROFIBUS-DP master.
  • Transmission speed range up to 12 Mbit/s allows matching network performance requirements.
  • Parameter configuration by module setup switches or controller program provides flexible commissioning options.
  • Maximum of eight combined PF611/PF612 (or A-version) modules per system limits total network interface count.
  • Ambient temperature rating of 0–45 °C with recommended forced-air cooling above this range affects installation environment selection.

FAQ

What is the Toshiba PF612?
It is a PROFIBUS-DP slave communication module for Toshiba Integrated Controller V Series model 2000 and nv series controllers.

Which systems is the PF612 compatible with?
It is compatible with Integrated Controller V Series model 2000 (S2T/S2E) and Unified Controller nv series type1 light systems via the G2 I/O bus.

What data size does the PF612 support?
It supports cyclic process data of up to 244 bytes input and 244 bytes output.

What transmission speeds are supported?
Transmission speeds range from 9.6 kbit/s to 12 Mbit/s.

How is the module configured?
Parameters are set either by switches on the module or by the controller application program.

What is the operating temperature range?
The module is rated for 0 to 45 °C ambient temperature; forced-air cooling is recommended above this range.