Description
3. Key Technical Specifications
| Parameter | Value |
|---|---|
| Product Type | Varistor Board / Surge Suppression Module |
| Compatible Drives | ABB ACS600, ACS800 series (also referenced with ACS580) |
| Component Type | Metal Oxide Varistor (MOV) assembly |
| Function | Overvoltage protection / transient suppression |
| Mounting | PCB mount / slide-in module |
| Protection Class (typical) | IP20 (internal component) |
| Material | Sintered metal oxide / phenolic resin housing |
| Energy Handling | High energy absorption capability |
| Associated Part Number | 57620170 |
| Application | Industrial VFD input protection |
4. Product Introduction
The ABB NVAR-45 is a varistor board designed for overvoltage and transient surge protection in ABB ACS600 and ACS800 series frequency converters. It uses a metal oxide varistor (MOV) assembly to clamp voltage spikes caused by lightning, capacitor switching, or inductive load events.
Installed as a PCB or slide-in module, the NVAR-45 diverts excess energy away from the drive’s rectifier and power electronics. This prevents damage to sensitive components and helps maintain long-term reliability of the VFD in industrial environments with unstable or noisy power supplies.

NVAR-45

NVAR-45
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| Drive trips on overvoltage | Failed or degraded varistor board | ✅ High | Inspect NVAR-45 for discoloration, cracking, or burn marks | Replace the board if visual damage is present |
| Repeated input stage failures | Missing or ineffective surge protection | ✅ High | Confirm NVAR-45 is installed and correctly seated | Install or replace the module before further operation |
| No visible damage but protection lost | End-of-life MOV degradation | ✅ Medium | Compare with known-good unit or measure clamping behavior if possible | Replace as preventive maintenance after major surge events |
| Drive powers up normally | External power quality issue | ❌ Low | Check supply voltage and upstream protection | Address line-side transients; do not condemn the NVAR-45 first |
| Module will not seat properly | Bent pins or incorrect revision | ✅ Medium | Visually inspect connector and board edges | Verify correct part number and orientation |
If the drive continues to fault after these checks, record the exact fault codes, note any recent power events, photograph the NVAR-45 installation, and contact technical support with the drive serial number and firmware version.
6. Frequently Asked Questions (FAQ)
Q: Which ABB drives use the NVAR-45?
The NVAR-45 is primarily specified for ACS600 and ACS800 series frequency converters. Some references also list compatibility with ACS580 systems. Always verify against the specific drive hardware manual.
Q: Is the NVAR-45 the same as part number 57620170?
Yes. 57620170 is the common associated or alternative reference number for the NVAR-45 varistor board.
Q: Can I run the drive without the NVAR-45 installed?
It is not recommended. The module provides essential surge protection for the input stage. Operating without it increases the risk of rectifier or IGBT damage during voltage transients.
Q: Is this a field-replaceable part?
Yes. It is designed as a slide-in or PCB-mount module. Power down the drive, follow lock-out/tag-out procedures, and observe ESD precautions when handling.
Q: How do I know if the varistor board has failed?
Look for physical signs such as cracked or discolored MOVs, burn marks, or a strong burnt smell. In many cases the board shows clear visual evidence after a high-energy surge event.
Q: Why is surplus pricing available for this part?
These are new original or new-surplus units that have never been installed in a drive. They are inspected for physical condition and carry a standard warranty. OEM lead times for ACS series accessories can vary; ready stock reduces downtime.
Q: Does the NVAR-45 require configuration or software?
No. It is a passive protection component. Once correctly installed it functions without parameter settings.