Description
Core Product Summary
The ABB PFEA112-65 (order number 3BSE050091R65) is the IP65 version of ABB’s PFEA112 Tension Electronics, a web tension measurement unit used with ABB force measurement systems in paper, printing, and other web-processing lines. It accepts signals from two load cells, processes them with adjustable filtering, and presents values for A, B, A+B, and A−B on a multi-language digital display with configuration keys.
Each unit provides one scaled voltage output (−5 to +11 V) and one current output (0–21 mA) plus PROFIBUS-DP fieldbus communication as standard, with alarm reporting available over PROFIBUS. The IP65 housing allows installation close to the measuring point outside a control cabinet, powered by 24 V DC or 100–240 V AC. Tension can be displayed in selectable units including N, kN, kg, and lbs, and a resettable maximum-load memory supports maintenance follow-up.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Tension electronics for web tension measurement (IP65 housing version) |
| ABB type designation | PFEA112-65 |
| Order number / Product ID | 3BSE050091R65 |
| Enclosure rating | IP65 |
| Number of load cells | 2 |
| Load cell excitation | 0.5 A rms, 330 Hz |
| Maximum excitation load | 2 load cells plus 5 Ω cable resistance |
| Analog outputs (PFEA112) | 1 × −5 to +11 V (max. load 5 mA); 1 × 0–21 mA (max. load 550 Ω) |
| Analog output filtering | Selectable filter, step response (0 to 90%) settable per output: 15 / 30 / 75 / 250 / 750 / 1500 ms |
| Analog output scaling | Individual scaling and zeroing per output |
| Fieldbus communication | PROFIBUS-DP (standard on PFEA112) |
| Alarm reporting | Via PROFIBUS; Status OK LED (green/red) |
| Display | 2 × 16-character multi-language display with configuration keys |
| Display modes | A, B, A+B, A−B load cell signals; sum, difference, or individual |
| Selectable tension units | N, kN, kg, lbs, N/m, kN/m, kg/m, pli |
| Power supply (DC) | 24 V DC (18–36 V) |
| Power supply (AC, IP65 version) | 100 (−15%) to 240 (+10%) V AC, 47–63 Hz |
| Power consumption | 8 W at 24 V |
| Self-diagnostics | Built-in, continuous supervision with error messages; Status OK LED |
| Maximum load memory | Yes, resettable |
| Zero offset memory | Yes |
| Country of origin | Sweden |
| Gross weight | 1 kg |
| Scope of delivery | Unit including a CD user manual |

PFEA112-65

PFEA112-65
Detailed Product Overview
The PFEA112-65 sits between the load cells of a web tension measuring point and the control system. It excites up to two load cells, amplifies and filters the measurement signals, and converts them into scaled analog values and PROFIBUS-DP telegrams that a PLC or DCS can use for tension control or monitoring. In ABB’s tension electronics range, the “112” model covers applications requiring two measuring points with analog outputs and PROFIBUS communication, while the “-65” suffix identifies the IP65 enclosed version; the same electronics are also offered in a DIN-rail housing.
The IP65 enclosure is the defining installation decision for this variant. It permits mounting directly on the machine frame or measuring roll structure, close to the load cells, without a protective control cabinet — useful on paper machines, coating lines, and printing presses where cabinet space is limited or cable runs to the measuring point need to be short. The unit accepts either 24 V DC (18–36 V) or 100–240 V AC (47–63 Hz) supply, and consumes 8 W at 24 V, so a small power feed is sufficient.
Signal conditioning deserves attention at commissioning. Each analog output can be scaled and zeroed individually, and the selectable output filter — with step responses from 15 ms to 1500 ms — lets the engineer balance measurement speed against mechanical vibration from the machine. This matters because an under-filtered tension signal makes the control loop react to roll eccentricity and machine noise rather than true web tension. The 0–21 mA current output suits long cable runs to a controller input, while the −5 to +11 V voltage output supports bipolar presentation of the A−B difference signal.
Two further features reduce engineering effort. The interactive multi-language menu guides parameter setting step by step on the 2 × 16 character display, and the same display presents individual, summed, or differential tension in selectable engineering units (N, kN, kg, lbs, or per-meter/pli values), eliminating unit conversion in downstream logic. Built-in self-diagnostics continuously supervise the measurement chain; faults are indicated by a green/red Status LED and reported over PROFIBUS. The resettable maximum-load memory stores peak load values, which is practical when checking whether a measuring point has been mechanically overloaded between maintenance rounds.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Fieldbus | PROFIBUS-DP as standard on PFEA112 | Device description handled via the ABB GSD file for PFEA112 |
| Alarm handling | Alarm transmission via PROFIBUS; Status OK indicated by green/red LED | Controller program should monitor the PROFIBUS alarm and status data |
| Load cell connection | 2 load cells; excitation 0.5 A rms at 330 Hz; max. 2 load cells plus 5 Ω cable resistance | Check cable resistance within the stated limit when the electronics are mounted away from the cells |
| Analog output loads | Voltage output max. 5 mA; current output max. 550 Ω | Verify the receiving controller input impedance matches these limits |
| Power supply | 24 V DC (18–36 V) or 100 (−15%) to 240 (+10%) V AC, 47–63 Hz | Select the feed according to the on-site supply available at the mounting location |
| Installation environment | IP65 enclosure | Suitable for mounting outside a control cabinet, close to the measuring point |
| Ordering | 3BSE050091R65; minimum order quantity and order multiple of 1 piece | Unit supplied including a CD user manual |
| System context | Part of ABB’s web tension measurement product families (PFT100 / PFR100 / PFC300-PFT300 categories) | Match the measuring roll and load cell hardware to the application requirements |
FAQ
What is the ABB -65?
It is the IP65-enclosed version of the PFEA112 Tension Electronics, an ABB web tension measurement unit (order number 3BSE050091R65) that processes signals from two load cells and supplies scaled analog outputs and PROFIBUS-DP communication.
What is the difference between PFEA112-20 and PFEA112-65?
The suffix identifies the housing: “-65” is the IP65 enclosure version for mounting outside a control cabinet, while the PFEA112 is also available in a DIN-rail housing for cabinet installation. The measurement electronics and PROFIBUS-DP interface are common to the model.
How many load cells can it handle?
Two. Excitation is 0.5 A rms at 330 Hz, and the maximum excitation load is two load cells plus 5 Ω of cable resistance.
What outputs does it provide?
One voltage output of −5 to +11 V (maximum load 5 mA) and one current output of 0–21 mA (maximum load 550 Ω), each individually scalable and zeroable, with a selectable filter whose step response (0 to 90%) can be set to 15, 30, 75, 250, 750, or 1500 ms.
Which fieldbus does it use?
PROFIBUS-DP is standard on the PFEA112. Alarms and status information are transmitted via PROFIBUS, and device integration uses ABB’s GSD file for PFEA112.
What power supply does it need?
Either 24 V DC (18–36 V) or, on the IP65 version, 100 (−15%) to 240 (+10%) V AC at 47–63 Hz. Power consumption is 8 W at 24 V.
What can the display show?
A 2 × 16-character multi-language display presents the individual load cell signals A and B, their sum A+B, or their difference A−B, with tension selectable in units such as N, kN, kg, lbs, N/m, kN/m, kg/m, or pli.
Does it support maintenance diagnostics?
Yes. Built-in self-diagnostics continuously supervise key parameters and report errors, a green/red Status LED indicates normal operation, and a resettable maximum-load memory stores peak load values for maintenance checks.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626