ABB PP826 3BSE042244R1 Panel 800 Operator Panel

Parameter Specification
Manufacturer ABB
Model PP826
Product reference 3BSE042244R1
Product family Panel 800
Product type Keypad operator panel / HMI
Display technology Transmissive color STN-LCD
Display resolution 320 × 240 pixels
Display colors 64K
Active display area, W × H 115.2 × 86.4 mm
Backlight CCFL
Categories: , , , , SKU: PP826 3BSE042244R1 Brand:

Description

Core Product Summary

ABB PP826 3BSE042244R1 is a Panel 800 operator interface for displaying process information and issuing configured commands to connected automation equipment. The PP826 combines a membrane keyboard with a 320 × 240-pixel color STN-LCD. Its application is created in Panel Builder 800 and transferred to the panel, supporting functions such as dynamic indication, alarms, recipes, and time channels.

The panel operates from 24 V DC nominal power, with an allowable supply range of 20–30 V DC. Ethernet, RS-232C, and RS-422/RS-485 interfaces provide connection options, subject to the selected controller driver and cable. For cabinet integration, the PP826 requires a 240 × 130 mm cutout and has a 57 mm mounting depth, increasing to 157 mm with the specified clearance. Its front seal is IP66; the rear is IP20 and requires protection within the installation.

 

Key Technical Specifications

Parameter Specification
Manufacturer ABB
Model PP826
Product reference 3BSE042244R1
Product family Panel 800
Product type Keypad operator panel / HMI
Display technology Transmissive color STN-LCD
Display resolution 320 × 240 pixels
Display colors 64K
Active display area, W × H 115.2 × 86.4 mm
Backlight CCFL
Operator input Membrane switch keyboard with metal domes
Application flash memory 12 MB, including fonts
Nominal supply voltage 24 V DC
Allowable supply range 20–30 V DC
Current consumption at rated voltage Normal: 0.3 A; maximum: 0.5 A
Power connection 3-pin connection block
Ethernet connection Shielded RJ45
RS-422/RS-485 connection Female 25-pin D-sub
RS-232C connection Male 9-pin D-sub
USB Type A host, USB 1.1; maximum output current 500 mA
Front-panel dimensions, W × H × D 275 × 168 × 6 mm
Panel cutout, W × H 240 × 130 mm
Mounting depth 57 mm; 157 mm including clearance
Weight 1.2 kg
Front / rear protection IP66 / IP20
Operating temperature, vertical installation 0 to +50 °C
Operating temperature, horizontal installation 0 to +40 °C
Storage temperature −20 to +70 °C
Relative humidity 5–85%, non-condensing
Configuration software Panel Builder 800

Display, current-consumption, and backlight values above are for PP826, not the separately specified PP826A.

 

Engineering Selection Highlights

  • STN-LCD with CCFL backlight → identifies the PP826 display configuration; PP826A TFT/LED values must not be substituted into its specification.
  • 240 × 130 mm cutout → provides a precise cabinet-fit criterion beyond the external front-panel dimensions.
  • 57 mm mounting depth and 157 mm depth including clearance → reserve rear space for installation rather than assessing fit from the panel body alone.
  • IP66 front and IP20 rear → the front seal does not make the complete panel suitable for unprotected exposure on all sides.
  • Ethernet and two serial interfaces → select the connection according to the configured controller driver and its cable requirements; a matching connector alone does not establish protocol compatibility.
  • Orientation-dependent temperature limits → horizontal installation has a lower maximum operating temperature than vertical installation.
  • Panel Builder 800 configuration → the panel requires an engineered application; the hardware model does not define the installed screens, alarms, or controller connection.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Engineering software Panel Builder 800 Create the HMI project on a computer, then transfer it to the panel.
Connected equipment PLCs, servos, drives, and other supported automation equipment Connection depends on the applicable driver and project configuration.
Ethernet Built-in shielded RJ45 connection Supports Ethernet/TCP/IP project transfer when configured in the engineering tool.
Serial interfaces RS-232C and RS-422/RS-485 Cable selection follows the instructions for the relevant controller driver.
AC 800M connection TK212A connection cable documented for Panel 800–AC 800M The cable relationship does not remove the need for correct driver and project settings.
PROFIBUS DP Requires an expansion module PROFIBUS DP is not a built-in panel port; expansion-unit restrictions also apply in hazardous-area installations.
Supply 24 V DC nominal, 20–30 V DC operating range Correct polarity and an appropriately specified supply are required.
Grounding Panel and controller must share the required electrical reference Ground-potential differences can affect communication.
Safety functions Emergency stop and other safety functions must not be controlled from the panel Keep the HMI outside the safety-function implementation.

These dependencies describe the PP826 installation and configuration requirements, not unconditional compatibility with every device using the same electrical interface.

 PP826 3BSE042244R1

PP826 3BSE042244R1

Dimensions, Mounting & Connection Notes

 

Panel fit and mechanical installation

Installation Parameter Requirement
Front panel, W × H × D 275 × 168 × 6 mm
Cutout, W × H 240 × 130 mm
Installation-plate thickness 1.5–7.5 mm
Mounting depth 57 mm
Depth including clearance 157 mm
Fastening Six supplied brackets and screws
Mounting-fastener torque 0.5–1.0 Nm
Weight 1.2 kg

The PP826 is intended for stationary installation on a flat surface. Keep the enclosure’s ventilation openings unobstructed.

 

Power, grounding, and cabling

Connect the panel to a 20–30 V DC supply through its 3-pin power connection. For the specified UL/cUL installation, power-terminal wiring uses AWG 28–12 conductors with a minimum tightening torque of 0.5 Nm. The power supply must satisfy the applicable installation requirements, including Class II requirements for UL/cUL installations.

Use a short grounding conductor of at least 2.5 mm² with an M5 grounding screw. The mounting clamps do not provide a secure grounding connection by themselves. Separate high-voltage wiring from signal and supply wiring, and use communication cabling appropriate to the interface and installation.

 

Environmental installation limits

Maintain 0 to +50 °C for vertical installation or 0 to +40 °C for horizontal installation, with 5–85% non-condensing relative humidity. The relevant temperature is the environment cooling the panel electronics inside the cabinet, not simply the room temperature outside it. Avoid direct sunlight and large, sudden temperature changes.

 

Applications & System Role

The PP826 provides the operator-facing layer between personnel and a connected control system. Its configured application can present text and dynamic process indications, handle alarms and recipes, and issue operator commands through the selected communication driver. The PLC, drive, servo, or other connected equipment remains responsible for its own control functions.

A relevant technical-fit scenario is a cabinet requiring physical-key operation, a color graphical display, and Ethernet or serial communication to automation equipment. Selection should be based on the existing project, controller driver, cabinet cutout, supply, and installation environment—not on the broad Panel 800 family name alone.

The panel is not a safety-function controller. Emergency-stop and other safety functions must be implemented outside the operator panel.

 

Detailed Product Overview

The PP826 combines a physical keyboard with a graphical display, making both the operator application and the cabinet interface important parts of selection. Its screens, indications, alarms, recipes, and commands are defined in a Panel Builder 800 project. The project is then transferred to and stored in the panel. An identical hardware model can therefore present different operating interfaces depending on the application loaded into it.

Display identification is particularly important for this model. PP826 uses a transmissive color STN-LCD with CCFL illumination, whereas PP826A is separately specified with a TFT-LCD and LED backlight. These are not interchangeable specification labels. The distinction also affects documented current consumption: PP826 is rated at 0.3 A normal and 0.5 A maximum at nominal voltage.

Communication selection requires more than choosing Ethernet or a serial connector. The panel’s configured driver determines how it exchanges information with the controller, and the driver instructions determine the required cable. RS-232C uses a male 9-pin D-sub, while RS-422/RS-485 uses a female 25-pin D-sub. PROFIBUS DP requires an additional expansion module rather than a direct connection to a built-in PROFIBUS port.

Electrical isolation is another integration boundary. The panel has isolation from its 24 V DC supply, but the RS-232, RS-422/RS-485, and USB communication ports are not galvanically isolated from one another. Ethernet has galvanic isolation. In systems with differing ground potentials, the communication layout and any external isolation must therefore be considered as part of the installation.

Mechanical fit should be assessed using both cutout and clearance information. The front panel measures 275 × 168 mm, but the required opening is 240 × 130 mm. The 57 mm mounting depth increases to 157 mm when clearance is included. Likewise, IP66 applies to the front seal, while the rear remains IP20. These distinctions determine how the panel must be incorporated into an enclosure.

Finally, the HMI must remain separate from the safety architecture. Operator commands and alarm presentation do not make the panel suitable for emergency-stop or other safety functions. Its role is process interaction through the configured application, within the stated electrical and environmental installation limits.

 

FAQ

 

What is ABB PP826 3BSE042244R1?

ABB PP826 is a Panel 800 keypad operator interface used to display process information and provide configured operator commands to connected automation equipment. Its application is engineered in Panel Builder 800.

 

Does PP826 use the same display technology as PP826A?

No. PP826 uses a color STN-LCD with a CCFL backlight; PP826A is separately specified with a TFT-LCD and LED backlight. Both are listed with 320 × 240-pixel resolution, but their display and current-consumption specifications differ.

 

What power supply does PP826 require?

PP826 requires 24 V DC nominal power and accepts 20–30 V DC. Its normal current consumption is 0.3 A, with a maximum of 0.5 A at rated voltage.

 

Which communication interfaces are built in?

The panel provides Ethernet, RS-232C, RS-422/RS-485, and a USB 1.1 Type A host port. Controller communication depends on the selected driver, project settings, and appropriate cable.

 

What cabinet cutout and mounting depth are required?

The cutout is 240 × 130 mm, and the mounting depth is 57 mm. Allow 157 mm depth when including the specified clearance, and use an installation plate 1.5–7.5 mm thick.

 

Is the entire panel IP66?

No. The front seal is IP66, while the rear is IP20. The installation must protect the rear and maintain the required ventilation space.

 

What are the operating-temperature limits?

The operating range is 0 to +50 °C when installed vertically and 0 to +40 °C when installed horizontally. Relative humidity must remain within 5–85%, non-condensing.

 

Can PP826 control an emergency-stop function?

No. Emergency stop and other safety functions must not be controlled from the operator panel.