Sale!

Aerotech NDRIVECP30-S 30A PWM Servo Drive

  • Model: NDRIVECP30-S
  • Brand: Aerotech
  • Series: Ndrive CP Compact PWM Network Digital Servo Drives
  • Core Function: High-performance servo motor amplification and motion control
  • Product Type: Single-axis PWM digital servo drive / amplifier
  • Key Specs: 10 A continuous / 30 A peak, 14–240 VAC motor supply, internal 40 W shunt resistor
  • Condition: New Original / New Surplus
Categories: , , , , SKU: NDRIVECP30-S Brand:

Description

Key Technical Specifications

Parameter Value
Drive family Aerotech Ndrive CP
Model NDRIVECP30-S
Motor types Brushless servo, DC brush servo, voice coil, and stepper motors
Output current 10 A continuous, 30 A peak
Motor supply voltage 14–240 VAC, single phase
Motor supply frequency 50–60 Hz
Control supply voltage 100–240 VAC, 50–60 Hz
Inrush current 16 A at 115 VAC; 32 A at 230 VAC
PWM switching frequency 20 kHz
DC bus voltage 20–340 VDC
Internal shunt resistor 50 ohm, 40 W continuous, 400 W peak for 5 seconds
Feedback Encoder feedback; optional encoder multiplier
Digital inputs 6 optically isolated inputs, including 2 high-speed inputs
Digital outputs 4 optically isolated outputs
Analog I/O One 16-bit differential analog input; one 16-bit single-ended analog output
Control loops Digital current, velocity, and position loops
Weight 1.63 kg / 3.6 lb
Compatibility Aerotech A3200 motion-control platform

The NDRIVECP30-S is the 30 A-peak Ndrive CP configuration with an internal shunt resistor. Aerotech specifies 10 A continuous and 30 A peak output, a 14–240 VAC single-phase motor supply, 20 kHz PWM switching, and digital current, velocity, and position control loops.

 

Product Introduction

The Aerotech NDRIVECP30-S is a single-axis Ndrive CP PWM digital servo amplifier for precision motion systems using brushless, DC brush, voice-coil, or stepper motors. It integrates with the Aerotech A3200 platform and provides deterministic network-based motion control.

The -S suffix identifies the internal 50 ohm, 40 W shunt resistor, which dissipates regenerated energy during deceleration. With 30 A peak output, encoder feedback, optically isolated I/O, and a 16-bit analog input/output, this drive suits demanding positioning, scanning, inspection, semiconductor, and laboratory-motion applications.

NDRIVECP30-S

NDRIVECP30-S

NDRIVECP30-S

NDRIVECP30-S

Troubleshooting Quick Reference

Symptom Possible Cause Relevance to this Part Quick Check Method Recommendation
No LEDs or no response Control power, motor power, fuse, or wiring fault ❌ Low Measure control and motor supply voltages at TB terminals; inspect fuses and grounds Verify both control and motor power inputs before replacing the drive
Drive powers up but motor does not move Enable input inactive, command source missing, feedback fault, or drive fault ✅ High Check enable I/O, command source, encoder signal, and Aerotech software fault status Correct enable/command/feedback issues before condemning the drive
Drive trips on overcurrent Shorted motor phases, cable damage, excessive acceleration, or failed power stage ✅ High Disconnect motor and inspect phase-to-phase resistance; review fault code and current settings Test motor and cable independently; replace drive only after motor/cable checks pass
Overvoltage or shunt fault Regenerated energy, excessive deceleration, or failed internal shunt resistor ✅ High Measure DC-bus voltage during deceleration and inspect the -S shunt configuration Reduce deceleration, verify load inertia, or use an external shunt if required
Position error or unstable motion Encoder noise, incorrect feedback type, poor grounding, or gain tuning issue ✅ High Inspect encoder cable shielding, verify feedback selection, and review servo gains Correct feedback wiring and tuning before replacing hardware
No communication with A3200 Network cable, IP/address configuration, switch port, or firmware mismatch ✅ High Verify network link, IP settings, A3200 connection, and drive firmware Test network hardware and software configuration before replacing the drive
Overtemperature shutdown Poor heat sinking, blocked airflow, high ambient temperature, or excessive duty cycle ✅ High Inspect heatsink mounting and airflow; measure ambient and drive temperature Improve cooling or reduce duty cycle; replace only after thermal checks pass

If the fault remains unresolved, send photos of the drive nameplate, wiring, LED status, Aerotech software fault log, motor nameplate, and feedback configuration before ordering a replacement.

 

Frequently Asked Questions

Can I hot-swap the Aerotech NDRIVECP30-S?
No. Disconnect both the control supply and motor supply before removal or installation. The drive contains a PWM power stage and DC-bus capacitors that can retain hazardous voltage; allow discharge time and verify with a meter before handling.

Is the NDRIVECP30-S obsolete?
The Ndrive CP series is a legacy Aerotech product family, and Aerotech’s current catalog centers on newer Automation1 XC4, XA4, and iXC4 drive platforms. The NDRIVECP30-S is therefore generally available as New Surplus, refurbished, or tested pre-owned inventory.

What does the “-S” suffix mean?
On the Ndrive CP30, -S identifies the internal 50 ohm, 40 W continuous shunt resistor. It excludes the -EXTSHUNT external shunt-resistor option.

Will it directly replace another Ndrive CP model?
Only after matching current rating, supply voltage, feedback type, firmware, connector layout, and shunt configuration. A CP10 or CP20 is not a direct substitute for a CP30 if the application requires 30 A peak output.

Will my A3200 configuration remain after replacement?
Not automatically. Drive parameters, feedback configuration, I/O assignments, and network settings may need to be restored. Back up the A3200 project and drive configuration before removing the original unit.

Why is this surplus drive less expensive than a new OEM unit?
Because Aerotech no longer supplies the Ndrive CP as a current production platform, pricing reflects available surplus inventory rather than current OEM manufacturing. New Surplus stock is unused original product; it may have older date codes but should not have field-operating hours.

What should I check before ordering?
Confirm the required 30 A peak / 10 A continuous rating, 14–240 VAC motor supply, control-supply voltage, motor type, encoder feedback, internal versus external shunt requirement, and A3200 firmware compatibility. The Ndrive CP30-S includes the internal shunt by design.