Item Specification
Brand Allen-Bradley, Rockwell Automation
Catalog number 1756-L61A
Base catalog number 1756-L61
Product type ControlLogix 5561 controller
Control platform 1756 ControlLogix
Controller series Series A
User memory 2 MB
I/O memory 478 KB
Categories: , , , , SKU: 1756-L61A Brand:

Description

Core Product Summary

The Allen-Bradley 1756-L61A is a Series A ControlLogix 5561 controller, also cataloged as the 1756-L61 2 MB Memory Controller. It provides the processing and program-memory function for a 1756 ControlLogix automation system, executing control logic and coordinating I/O, communication, and motion-related system resources.

This controller provides 2 MB of user memory and 478 KB of I/O memory. It installs in a 1756 ControlLogix chassis and can occupy any chassis slot; more than one controller may be used in the same chassis. A Series A 1756-L61 uses a 1756-BA1 battery or a 1756-BATM battery module, and nonvolatile storage uses a 1784-CF64 Industrial CompactFlash card.

 

Key Technical Specifications

Item Specification
Brand Allen-Bradley, Rockwell Automation
Catalog number 1756-L61A
Base catalog number 1756-L61
Product type ControlLogix 5561 controller
Control platform 1756 ControlLogix
Controller series Series A
User memory 2 MB
I/O memory 478 KB
Chassis installation Any 1756 ControlLogix chassis slot
Multiple controllers More than one controller may be installed in the same chassis
Battery, Series A 1756-BA1 battery or 1756-BATM battery module
Nonvolatile storage card 1784-CF64 Industrial CompactFlash card
Current draw 1.20 A at 5.1 V DC; 14 mA at 24 V DC
Power dissipation 3.5 W
Heat dissipation 11.9 BTU/hr
Weight 0.32 kg (11.3 oz)
Programming software RSLogix 5000
Reference documentation 1756-TD001 technical data; 1756-UM001 user manual

 

Engineering Selection Highlights

  • The 1756-L61A is a Series A ControlLogix 5561 controller. Confirm the series letter on the installed unit before selecting a replacement, because Series A and Series B controllers have different battery-installation arrangements.
  • It provides 2 MB of user memory and 478 KB of I/O memory. These memory allocations determine the controller’s capacity for application logic and I/O-related data within the ControlLogix system.
  • It installs in any slot of a 1756 ControlLogix chassis. This allows flexible controller placement, although chassis power capacity and the overall system configuration must still be engineered for the application.
  • More than one 1756 controller can reside in the same chassis. This supports multi-controller ControlLogix architectures where tasks, communication, or process areas are partitioned across controllers.
  • A Series A unit requires a 1756-BA1 battery or 1756-BATM battery module. Using an unsupported battery can damage the controller, so battery selection must follow the Series A requirement.
  • Nonvolatile storage requires a 1784-CF64 Industrial CompactFlash card. The card is optional and is not supplied with the controller, so it must be specified separately when project retention or firmware/project storage is required.
  • RSLogix 5000 is the associated programming environment. Controller firmware revision and software version must be coordinated during configuration or replacement.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Control platform 1756 ControlLogix The controller is part of the 1756 ControlLogix system.
Chassis 1756 ControlLogix chassis It can be installed in any chassis slot.
Multiple controllers Supported in the same chassis More than one ControlLogix controller may be installed in one chassis.
Battery, Series A 1756-BA1 or 1756-BATM Use only the battery type specified for a Series A 1756-L61.
Nonvolatile storage 1784-CF64 Industrial CompactFlash card The card is optional and must be installed when nonvolatile storage is required.
Programming software RSLogix 5000 Controller configuration and application development use RSLogix 5000.
Firmware Rockwell-supported 1756-L61 firmware revisions Firmware revision must be compatible with the installed memory board and system software.
1756-L61A

1756-L61A

Dimensions, Mounting & Connection Notes

Item Verified information
Weight 0.32 kg (11.3 oz)
Chassis mounting Installs into a 1756 ControlLogix chassis slot
Slot position Any slot in the chassis
Installation state The controller can be installed or removed while chassis power is on and the system is operating
Installation sequence Insert the key, turn it to PROG, align the module with the chassis guides, slide it fully home, and engage the top and bottom latches
Battery, Series A Connect a 1756-BA1 battery or 1756-BATM battery module; record the battery date on the label inside the controller door
Memory board Install the memory board by aligning its connectors and gently pressing the boards together at the connector area

Repeated insertion and removal can wear the module and chassis connector contacts. Worn contacts may increase electrical resistance and affect module operation.

 

Detailed Product Overview

The Allen-Bradley 1756-L61A is the Series A version of the 1756-L61 ControlLogix 5561 controller. In a 1756 ControlLogix system, it performs the processor function: it executes the control application, manages controller memory, and communicates with the other modules installed in the chassis.

The controller provides 2 MB of user memory and 478 KB of I/O memory. These figures define the controller’s capacity for project logic and I/O-related data. When selecting this controller for a new or replacement application, the available memory should be assessed against the project’s logic, tags, communication requirements, and I/O population rather than assumed solely from the controller designation.

The 1756-L61A is chassis-based rather than a stand-alone controller. It installs into any slot in a 1756 ControlLogix chassis, and the ControlLogix architecture permits multiple controllers in one chassis. This flexibility is useful when an application is partitioned into separate controllers, but it also means chassis slot assignment, power budget, communication-module placement, and network design must be planned as a system.

For a Series A 1756-L61, battery support is provided by either a 1756-BA1 battery or a 1756-BATM battery module. The installation instructions specify these battery types for the Series A controller and warn that other batteries may damage it. The battery date should be recorded on the label inside the controller door to support battery-replacement planning.

Nonvolatile storage is handled through a 1784-CF64 Industrial CompactFlash card. This card is optional and is not included with the controller. Where project retention, firmware storage, or a defined recovery approach depends on removable nonvolatile storage, the CompactFlash card must be included in the bill of materials and configured according to the controller documentation.

The controller is programmed with RSLogix 5000. Firmware revision is a practical integration constraint: Rockwell’s compatibility resources list multiple firmware revisions for the 1756-L61, and the installed memory board must be compatible with the controller firmware revision. Before replacing or upgrading a controller, the existing firmware revision, memory-board configuration, project software version, and chassis configuration should be recorded.

 

Applications & System Role

The Allen-Bradley 1756-L61A serves as the central controller in a 1756 ControlLogix automation system. It executes the control program, retains application and I/O memory, and coordinates the chassis-based modules that provide I/O, communication, motion, and other system functions.

Its 2 MB user-memory capacity makes it suitable for ControlLogix applications whose logic and data requirements fit that allocation. In a multi-controller chassis, it can operate alongside other ControlLogix controllers, allowing the automation architecture to divide control responsibility across more than one processor. The controller does not itself provide field I/O; I/O and communication modules are installed separately in the ControlLogix chassis.

 

FAQ

What is the Allen-Bradley 1756-L61A?
It is a Series A ControlLogix 5561 controller, identified by catalog number 1756-L61A and base catalog number 1756-L61.

How much memory does the 1756-L61A provide?
It provides 2 MB of user memory and 478 KB of I/O memory.

Which chassis does it use?
It installs in a 1756 ControlLogix chassis and may be placed in any chassis slot.

Can more than one controller be used in the same chassis?
Yes. The ControlLogix installation documentation states that multiple controllers may be used in the same chassis.

Which battery does the Series A 1756-L61A require?
A Series A controller requires either a 1756-BA1 battery or a 1756-BATM battery module.

Which CompactFlash card is required for nonvolatile storage?
The controller uses a 1784-CF64 Industrial CompactFlash card for nonvolatile storage. The card is optional and is not supplied with the controller.

Which software is used to program it?
The controller is programmed with RSLogix 5000.

What should be checked before replacing a 1756-L61A?
Check the controller series, installed firmware revision, memory-board configuration, CompactFlash-card use, chassis slot and power budget, and the RSLogix 5000 project requirements.