Allen-Bradley 1756-OB16E ControlLogix 16-Pt DC Output

  • Model: 1756-OB16E
  • Brand: Allen-Bradley (Rockwell Automation)
  • Series: ControlLogix
  • Core Function: 16-point DC digitally fused output module
  • Product Type: Digital Output Module
  • Key Specs: 10–31.2 V DC; 1 A per point / 8 A per module; electronically fused (8 pts/group)
  • Condition: New Original / New Surplus
Categories: , , , , SKU: 1756-OB16E Brand:

Description

3. Key Technical Specifications

Parameter Value
Number of Outputs 16 electronically fused (8 points/group)
Voltage Category 12/24 V DC source
Operating Voltage Range 10…31.2 V DC
Current per Point, Max 1 A @ 60 °C
Current per Module, Max 8 A @ 60 °C
Surge Current per Point 2 A for 10 ms (repeatable every 2 s)
Minimum Load Current 3 mA per point
Output Delay (Off → On) 70 µs nominal / 1 ms max
Output Delay (On → Off) 360 µs nominal / 1 ms max
Backplane Current @ 5.1 V 250 mA
Backplane Current @ 24 V 2 mA
Power Dissipation, Max 4.1 W @ 60 °C
Isolation Voltage 250 V continuous, basic insulation
Removable Terminal Block 1756-TBNH or 1756-TBSH
Operating Temperature 0 °C to +60 °C

4. Product Introduction

The Allen-Bradley 1756-OB16E is a 16-point DC output module for ControlLogix systems. It provides electronically fused 10–31.2 V DC outputs arranged in two groups of eight points.

Each point is rated 1 A continuous (8 A module total) at 60 °C and includes electronic fusing that opens on overcurrent or short-circuit conditions. The module supports scheduled outputs, configurable fault/program states (Hold Last State, On, or Off), and installs in any 1756 ControlLogix chassis. It is commonly used for solenoid valves, relays, indicators, and other 24 V DC loads requiring point-level protection without external fuses.

5. Troubleshooting Quick Reference

Symptom Possible Cause Relevance to this Part Quick Check Method Recommendation
Output point will not turn on Electronic fuse tripped or open field circuit ✅ High Check point status LED and diagnostic tags in Studio 5000 Clear fuse fault; verify load wiring and current
Entire group offline Group fuse tripped or common wiring fault ✅ High Measure voltage at group common; inspect RTB Reset module or clear fault; repair common wiring
Module OK LED off / faulted Backplane power or chassis communication issue ❌ Medium Verify chassis power and module seating Reseat module; check chassis power supply
Output turns on but load does not energize Open field wiring or insufficient voltage ❌ Low Measure voltage at output terminal under command Repair field wiring or check field power supply
Intermittent output dropouts Overcurrent or inductive kick ✅ Medium Monitor current draw; check for inductive loads without suppression Add flyback diodes or reduce load current
High leakage keeps load partially on Leakage current + low-power load ❌ Low Measure off-state voltage/current Add bleeder resistor or select different module

If the fault remains unresolved, capture diagnostic tags, LED status, and field voltage readings before contacting support.

1756-OB16E

1756-OB16E

1756-OB16E

1756-OB16E

6. Frequently Asked Questions (FAQ)

Q: Is the 1756-OB16E still in production? Yes. The ControlLogix platform remains active. New and New Surplus units are widely available.

Q: What is the difference between 1756-OB16E and 1756-OB16D? Both are electronically fused. The OB16E is rated 1 A per point; the OB16D is rated 2 A per point. Choose OB16D for higher-current loads.

Q: Does the electronic fuse reset automatically? The fuse can be cleared via software command or by cycling power after the fault is removed. Persistent overloads will re-trip the fuse.

Q: What terminal blocks are required? Use a 1756-TBNH (screw-clamp) or 1756-TBSH (spring-clamp) 36-pin Removable Terminal Block. The module is not compatible with older 20-pin RTBs.

Q: Can I hot-swap the 1756-OB16E? Yes, ControlLogix supports removal and insertion under power (RIUP) when the chassis and system are properly configured. Follow Rockwell safety guidelines.

Q: What is the maximum current the module can supply? 1 A continuous per point and 8 A continuous for the entire module at 60 °C. Exceeding either limit will trip the electronic fuses.

Q: Why is New Surplus sometimes priced lower? These are genuine Allen-Bradley modules from excess inventory or cancelled projects. They are unused and typically supplied with anti-static protection. They are not refurbished unless specifically stated.