Description
3. Key Technical Specifications
| Parameter | Value / Description |
|---|---|
| Model | LC105A-1 |
| Manufacturer | ALSTOM |
| Module Type | Digital Discrete Output (Relay) |
| Number of Channels | 16 |
| Output Type | Relay contacts (isolated) |
| Compatible Platforms | ALSPA P320, T2000 Distributed Control System |
| Typical Field Loads | Interposing relays, solenoid valves, indicator lights |
| Isolation | High-integrity relay isolation from DCS backplane |
| Related Variants | LC105A-2 (24 V DC version), LC105 base, LC106 series |
| Mounting | Rack / chassis mount in ALSTOM DCS cabinets |
| Application | Power generation, turbine control, process interlocks |
4. Product Introduction
The ALSTOM LC105A-1 is a 16-channel digital discrete output module designed for the ALSPA P320 and T2000 distributed control systems. It converts control commands from the DCS logic into isolated relay outputs that drive field devices such as interposing relays, solenoid valves, and indicator lamps.
The module provides physical isolation between the sensitive DCS electronics and the higher-power field circuits, protecting the control system from back-EMF and electrical noise. It is commonly found in power generation plants for turbine trip systems, boiler controls, and process interlocks, as well as in other heavy industrial applications that use the ALSTOM T2000 / ALSPA platform.
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| Output channel does not energize | Failed relay or output circuit | ✅ High | Force output in diagnostics and measure contact | Replace module if contact remains open |
| Multiple channels fail | Backplane power or module seating | ✅ High | Check module status LEDs and power supply | Reseat module; verify rack power |
| Intermittent field device operation | Contact wear or wiring issue | ✅ Medium | Inspect field wiring and measure contact resistance | Clean or replace module; check field side |
| System reports output fault | Channel diagnostic detection | ✅ High | Review DCS diagnostic buffer for channel number | Isolate and test individual channel |
| No communication with module | Backplane or address conflict | ✅ Medium | Verify slot address and adjacent modules | Check configuration and replace if necessary |
| Relay chatters or sticks | Overload or inductive load without suppression | ✅ High | Inspect load type and suppression components | Add snubbers/diodes; reduce load or replace module |
Always follow lockout/tagout and DCS safety procedures. Capture diagnostic data before removing the module.

LC105A-1

LC105A-1
6. Frequently Asked Questions (FAQ)
Q: What system is the LC105A-1 used in?
It is a digital discrete output module for the ALSTOM ALSPA P320 and T2000 distributed control systems.
Q: How many output channels does it have?
16 relay output channels.
Q: What is the difference between LC105A-1 and LC105A-2?
The LC105A-1 and LC105A-2 are voltage/polarity variants of the same relay output family. Confirm the exact voltage rating required by your field devices.
Q: Can this module drive solenoid valves directly?
It is typically used to drive interposing relays or suitably rated solenoids. Always verify the contact rating against the actual load.
Q: Is the LC105A-1 still available new?
New production is limited. Genuine new-surplus and fully tested refurbished units are the most common supply sources for maintenance.
Q: What should I check before replacing the module?
Confirm the exact part number, slot location, and any configuration or addressing settings. Photograph the existing module labels and wiring for reference.
Install only in a powered-down or properly isolated rack, ensure correct seating on the backplane, and verify all output channels and diagnostics after power-up. This maintains reliable control of field devices in the ALSTOM DCS.