Description
Key Technical Specifications
- Model Number: EZ-S6M-F
- Manufacturer: AVG
- Product Category: Safety Relay Module
- Application: Machine safety control, emergency stop circuits, protective device monitoring
- Safety Function: Dual-channel safety input monitoring
- Input Type: Safety-rated contact inputs
- Output Type: Safety relay outputs
- Control Voltage: Verify exact voltage variant from nameplate and OEM documentation before installation
- Mounting Method: Industrial control cabinet mounting
- Connection Type: Screw terminal wiring interface
- Operating Environment: Industrial automation environments
- Compliance: Verify applicable safety standards according to OEM documentation and machine risk assessment
Product Introduction
The AVG EZ-S6M-F is a safety relay module designed for monitoring safety circuits in industrial machinery applications. It evaluates safety input devices such as emergency stop switches and protective interlocks, then controls safety-rated output switching circuits.
This module is typically used in machine automation panels where reliable safety circuit monitoring is required. Before replacement, confirm the exact electrical specifications, terminal assignment, and safety category requirements against the installed unit.
Installation & Configuration Guide
Stage 1: Pre-Installation Preparation (Approx. 10 minutes)
⚠️ Safety First:
Notify production personnel before shutdown. Place the machine in a safe condition, apply lockout/tagout procedures, isolate control power, and wait for stored energy discharge.
Tools Required:
- ESD wrist strap
- PH1 screwdriver
- Multimeter
- Wire labels
- Smartphone or camera for documentation
Data Backup:
- Record the existing module model number and wiring arrangement.
- Photograph all terminal connections before removal.
- Document safety circuit wiring, relay output assignments, and external devices connected to the module.
Stage 2: Removing the Old Module (Approx. 10 minutes)
Steps:
- Remove the control cabinet cover if required.
- Verify power is fully isolated using a multimeter.
- Label each wire before disconnecting terminals.
- Loosen terminal screws and remove wiring carefully.
- Release the DIN rail mounting clip or fixing mechanism.
- Remove the old safety relay module straight from the mounting position.
- Inspect the cabinet wiring, terminals, and DIN rail condition.
⚠️ Note:
Keep the original module until the replacement unit has passed functional testing.
Stage 3: Installing the New Module (Approx. 10 minutes)
Steps:
- Confirm the replacement unit is exactly AVG EZ-S6M-F before installation.
- Check the housing condition and terminal markings.
- Install the module onto the DIN rail.
- Reconnect wiring according to the documented terminal layout.
- Verify emergency stop channels, reset circuits, and safety outputs.
- Tighten terminals using appropriate torque.
Self-Checklist:
- Correct model installed
- Terminal wiring matches original configuration
- Safety input channels verified
- Output contacts checked
- DIN rail mounting secure
Stage 4: Power-On & Testing (Approx. 15 minutes)
Pre-Power Check:
- Check for incorrect wiring or short circuits.
- Verify supply voltage matches the module rating.
Power-On Steps:
- Restore control power.
- Observe module LED indicators.
- Test emergency stop activation.
- Verify safety outputs switch correctly.
- Test machine reset operation.
- Confirm the PLC or machine controller receives the expected safety status.
⚠️ Troubleshooting Note:
If the safety relay does not enable, check dual-channel input wiring, reset conditions, feedback loop status, and supply voltage before replacing the module again.

EZ-S6M-F

EZ-S6M-F
Frequently Asked Questions (FAQ)
Q1: Can the AVG EZ-S6M-F be hot-swapped while the machine is running?
No. Safety relay modules should not be removed or installed under power. Disconnect control voltage first. Removing a safety device during operation can create unexpected machine behavior and may damage terminals or connected equipment.
Q2: Is the AVG EZ-S6M-F obsolete?
Availability depends on remaining inventory and OEM production status. Some industrial safety components remain in service for many years after original production. Confirm stock condition before planning a replacement project.
Q3: Is this unit new or refurbished?
The available condition should be confirmed before purchase. New Original / New Surplus units are unused products stored in inventory. Refurbished units should include functional testing records before installation.
Q4: Will replacing the EZ-S6M-F affect machine safety settings?
The safety relay itself normally does not store PLC logic. However, the external wiring, reset circuit, feedback loop, and safety architecture determine system behavior. Always document the existing configuration before removal.
Q5: What should I verify before ordering a replacement?
Check:
- Exact model number: AVG EZ-
- Supply voltage rating
- Terminal arrangement
- Safety input configuration
- Output contact configuration
- Required safety category or performance level
Q6: Why is this product available below the original OEM price?
Industrial automation spare parts are often sourced from excess inventory, discontinued equipment stock, or maintenance inventories. Pricing depends on condition, availability, testing status, and market supply. Always confirm the product condition and test documentation before purchase.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626