Description
Core Product Summary (Brand / Model / Key Attributes)
The Bender WR150x350S (Part Number: B911740) is a highly sensitive, rectangular-type measuring current transformer engineered for residual current monitoring (RCM) and insulation fault location (EDS) systems. Operating within the Bender WR series transformer portfolio, this unit converts AC residual currents into evaluable signals for connected downstream Bender evaluation devices.
Featuring a 150 x 350 mm rectangular inner window opening, the WR150x350S is designed to surround large busbars or multi-conductor cable runs in heavy electrical distribution systems. It operates in grounded and ungrounded AC networks up to a highest system voltage of 720 V, converting residual currents and locating test currents into precise measurement signals over a two-wire connection line.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer | Bender GmbH & Co. KG |
| Model / Type Code | WR150x350S |
| Part Number | B911740 |
| Device Type | Rectangular measuring current transformer |
| Inner Window Dimensions | 150 mm × 350 mm |
| Highest System Voltage (Um) | AC 720 V |
| System Compatibility | Bender RCM/RCMS monitors & EDS insulation fault locators |
| Secondary Connection | 2-wire terminal connection |
| Primary System Use | High-current distribution & busbar systems |
| Standards Compliance | IEC 61869-2 |
Detailed Product Overview
The Bender WR150x350S functions as the primary sensing element in advanced residual current monitoring and insulation fault location architectures. By encircling all active conductors in a circuit (phases and neutral), the transformer monitors the vector sum of currents passing through the 150 x 350 mm window. Under normal operating conditions, the sum equals zero; an insulation breakdown or earth leakage creates a magnetic imbalance in the core, inducing a proportional secondary signal sent to the monitoring relay.
The rectangular WR series geometry is optimized for installations where round toroidal transformers cannot physically fit over wide copper busbar configurations or heavy multi-cable bundles. The WR150x350S is also utilized in combination with ISOMETER IRDH or PGH locating current injectors to detect test currents generated during active insulation fault location procedures.
Built into a robust industrial enclosure, the transformer is intended for control cabinet and switchgear mounting, offering high mechanical strength, stable measurement sensitivity, and reliable signal output over long cable runs.

WR150x350S

WR150x350S
Engineering Selection Highlights
- 150 x 350 mm Rectangular Window: Designed specifically to fit wide busbar runs and large conductor bundles in main distribution panels.
- AC 720 V Rated System Voltage: Certified for installation on industrial low-voltage electrical distribution systems up to 720 V AC.
- Dual Monitoring & Fault Location Role: Works with Bender RCM/RCMS residual current monitors and EDS insulation fault location systems.
- 2-Wire Signal Output: Connects to remote evaluation units via a straightforward two-wire measurement line.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Evaluation Device | Bender RCM, RCMS, and EDS series units | Connects via two-wire measurement cable interface. |
| System Voltage | Rated up to 720 V AC | Suitable for low-voltage power distribution networks. |
| Conductor Pass-through | All active phase conductors and neutral (L1, L2, L3, N) | Protective earth (PE) conductors must NOT pass through the window opening. |
| High-Current Busbars | Busbars and heavy cable assemblies | For heavy load systems; ensure conductors are physically centered within the window. |
Dimensions, Mounting & Connection Notes
- Internal Window Dimensions: 150 mm height × 350 mm width.
- Mounting Orientation: Designed for rigid mounting inside switchboards and power distribution cabinets around main busbar runs.
- Conductor Routing: All current-carrying line conductors must pass through the transformer aperture in the same physical direction. Cable shielding and PE lines must bypass the transformer entirely.
- Terminal Wiring: Connects to the evaluation unit using screw terminals for 2-wire signal transmission.
FAQ
What is the Bender WR150x350S?
The Bender WR150x350S (Part Number: B911740) is a rectangular measuring current transformer with a 150 x 350 mm window designed for residual current monitoring and insulation fault location systems.
What size busbars fit through the WR150x350S?
The internal aperture measures 150 mm by 350 mm, allowing it to accommodate large industrial busbar systems or thick multi-cable bundles.
Which conductors need to pass through the WR150x350S aperture?
All live system conductors (L1, L2, L3, and N if present) must pass through the transformer opening. Ground/PE wires must never pass through the aperture.
What systems connect to the WR150x350S?
It connects to Bender RCM/RCMS series ground-fault and residual current monitors as well as EDS series insulation fault locators.
What is the maximum system voltage rating?
The transformer is rated for a highest system voltage (Um) of AC 720 V.
Verification & Troubleshooting Notes
- Conductor Path Verification: Confirm that all active phase conductors and the neutral line pass through the window while the PE wire bypasses the core completely.
- Secondary Loop Continuity: Check resistance across the 2-wire secondary circuit leading to the evaluation device to verify line integrity.
- Centering Conductors: Position busbars centrally within the rectangular opening to prevent localized core saturation and measurement distortion under high load currents.
- Shield Grounding Check: Ensure that any cable shields are grounded properly before entering the transformer window and are not routed through the aperture.