Description
Key Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bosch Rexroth Indramat |
| Model | MKD041B-144-KG1-KN |
| OEM ordering number | R911260465 |
| Motor type | Permanent-magnet synchronous AC servo motor |
| Frame size / length | 041 / B |
| Winding code | 144 |
| Continuous standstill torque | 2.7 Nm |
| Continuous standstill current | 7.5 A |
| Peak current | 34 A |
| Maximum speed | 7,500 rpm |
| Torque constant | 0.4 Nm/A |
| Back-EMF constant | 36.3 V / 1,000 min⁻¹ |
| Winding resistance | 1.8 Ω |
| Feedback | Resolver with integrated multiturn absolute encoder |
| Absolute position range | More than 4,096 revolutions |
| Holding brake | Integrated, 2.2 Nm |
| Shaft | Plain shaft with shaft sealing ring |
| Flange size | 82 mm |
| Centering diameter | 50 mm |
| Connection | Connection box, Side B |
| Cooling | Natural convection |
| Ingress protection | IP65 |
| Insulation class | F |
| Weight | 4.4 kg |
The specifications above are based on published Bosch Rexroth Indramat MKD motor data and supplier listings for this exact type code.
Product Introduction
The Bosch Rexroth MKD041B-144-KG1-KN is a compact MKD-series permanent-magnet synchronous servo motor for positioning, indexing, pick-and-place, and small rotary-axis applications. Its 144 winding provides a 2.7 Nm continuous standstill torque and supports up to 7,500 rpm.
The KG1 feedback package combines a resolver with an integrated multiturn absolute encoder, retaining position through more than 4,096 revolutions after a drive power loss. The factory-installed 2.2 Nm holding brake, IP65 housing, plain sealed shaft, and 82 mm flange make this unit suitable for vertical axes and compact machines that cannot tolerate position loss during an outage.
Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| Drive reports motor-feedback fault | Broken resolver/encoder cable, damaged M23 connector, or feedback electronics failure | ✅ High | Inspect and reseat the feedback cable; check continuity and shield termination; swap with a known-good cable if available | Replace the cable first; replace the motor only if the fault follows the motor |
| Motor will not develop torque | Incorrect drive motor type code, phase wiring error, or failed power cable | ✅ High | Verify the drive’s motor type code is MKD041B-144-KG1-KN; check U/V/W continuity and insulation to ground | Correct the drive configuration and power wiring before condemning the motor |
| Motor overheats or trips thermal protection | Excessive duty cycle, blocked cooling, overloaded axis, or high ambient temperature | ⚠️ Medium | Measure motor case temperature; review drive torque/current trend and mechanical binding | Reduce load or duty cycle, clear airflow restrictions, and verify brake is fully releasing |
| Axis drifts or loses position after power cycle | Absolute-encoder battery/reference issue or incorrect homing configuration | ⚠️ Medium | Check drive diagnostics for absolute-position or battery alarms; record axis position before shutdown | Verify drive battery/reference procedure; do not assume the motor feedback has failed |
| Brake does not release | Missing 24 V DC brake supply, broken brake wires, or seized brake | ✅ High | Measure 24 V DC at the brake terminals during drive enable; listen for the release click | Repair the 24 V DC brake circuit first; confirm brake wiring and mechanical release |
| Excessive noise or vibration | Coupling misalignment, bearing wear, loose mounting bolts, or resonance | ⚠️ Medium | Inspect coupling concentricity and flange bolts; run at low speed and listen at the bearing end | Correct alignment and fasteners; replace the motor if bearing noise persists |
| Motor turns freely with drive disabled | Normal behavior when brake is released or absent | ❌ Low | Confirm whether the brake is energized; check for expected holding torque with drive disabled | This is not a motor fault if the brake circuit is intentionally de-energized |
If the fault remains after these checks, send the complete Bosch Rexroth drive diagnostic list, motor nameplate photo, and cable part numbers to technical support before ordering a replacement.

MKD041B-144-KG1-KN

MKD041B-144-KG1-KN
Frequently Asked Questions
Can I replace an MKD041B-144-KG0-KN with this KG1 version?
Not directly in every application. Both use the same 041B frame and 144 winding, but the KG1 version adds an integrated multiturn absolute encoder. Your drive must support that feedback configuration, and the machine may require a different homing or absolute-position setup.
Can I hot-swap this servo motor?
No. Disable the drive, remove mains and 24 V DC control power, and wait for the bus to discharge before disconnecting power or feedback cables. The holding brake may release when its 24 V DC supply is removed, so support any vertical load first.
Will the absolute encoder retain position without drive power?
The KG1 feedback provides multiturn absolute position over more than 4,096 revolutions. Exact battery, reference, and commissioning behavior depends on the paired Rexroth drive; verify the drive manual and diagnostic messages before relying on it after a shutdown.
Which Rexroth drives work with this motor?
MKD motors are used with Rexroth Indramat DDS, DKS, DKC, HDS, and HDD servo drive families. Confirm the drive’s supported motor type code and feedback interface before installation.
Why is my replacement motor physically similar but performs differently?
The winding code matters. A 144 winding is not interchangeable with another code such as 058 or 035 without reviewing torque, current, speed, and drive scaling. The suffix must match the application’s motion profile and the drive configuration.
Is the holding brake suitable for stopping a moving load?
No. The 2.2 Nm brake is a holding brake for a stationary axis, typically after drive disable or power loss. Use the servo drive and motion profile to decelerate the load; do not use the brake as the primary stopping device.
What condition is this motor supplied in?
This listing is for New Original / New Surplus stock, not a repaired or used motor. Each unit is inspected, function-tested, and shipped in ESD-safe packaging with a test report; photos and test documentation are available on request.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626