Description
Key Technical Specifications
| Parameter | Value |
|---|---|
| Motor type | Digital synchronous AC servo motor, brushless, permanent magnet |
| Motor size / length code | 071 / B |
| Winding code | 035 |
| Continuous torque at standstill | 5.3 Nm (60 K) / 8 Nm (convection) / up to 12 Nm with surface cooling |
| Peak torque | Up to ~19.2 Nm (series-dependent) |
| Characteristic speed / Max speed | 2,500 rpm / 4,500 rpm |
| Torque constant | 0.91 Nm/A |
| Holding brake | 5 Nm, 24 V DC release voltage, brake mass approx. 0.62 kg |
| Feedback system | Resolver + integrated multiturn absolute encoder, absolute range 4,096 revs |
| Shaft design | Plain shaft with shaft sealing ring |
| Cooling | Natural convection (surface cooling/blower variants available in series) |
| Protection rating | IP65 |
| Insulation class | Class F winding system |
| Ambient temperature range | 0 to +40 °C |
| Drive compatibility | Rexroth IndraDrive, ECOdrive, DIAX family drive controllers |
| Typical applications | Printing, paper processing, metal cutting, handling, packaging, machine tools |
Verify torque and current ratings against the Rexroth MKD Project Planning Manual for your specific cooling configuration. Continuous torque depends heavily on cooling method — the 8 Nm figure assumes convection cooling; the same motor on a blower or surface-cooled setup delivers 12 Nm.
Product Introduction
The MKD071B-035-KG1-KN is a mid-frame synchronous servo motor from Bosch Rexroth’s Indramat MKD series. It serves printing presses, paper processing lines, metal cutting machines, and packaging systems where continuous torque in the 5–8 Nm class is required. The 071 frame bridges the gap between compact axis motors and main spindle duty.
The 5 Nm holding brake makes this unit the standard choice for Z-axes and vertical handling — it holds the load through an e-stop without a mechanical backup. The resolver-plus-multiturn-absolute encoder combination means the drive reads true position over 4,096 revolutions after any power loss, eliminating homing cycles on machines where a homing run means a 20-minute production restart. Pair it with an IndraDrive controller and it runs for decades — which is exactly why plants keep sourcing this discontinued motor rather than re-engineering the axis.

MKD071B-035-KG1-KN

MKD071B-035-KG1-KN
Installation & Configuration Guide
Stage 1: Pre-Installation Preparation (~15 min)
- ⚠️ Safety First: Notify operations of the downtime window. Jog the axis to a serviceable position. This motor has a 5 Nm brake — if your load exceeds that, it WILL drop when power is removed. Block vertical axes mechanically before doing anything else. Lock out/tag out the drive cabinet, kill the 24 V brake circuit separately, wait 5 minutes for DC bus discharge, then verify the bus reads below 60 V DC with a multimeter.
- Tools Required: Grounded ESD wrist strap, multimeter (Fluke 115 or equivalent), hex key set, torque wrench, dial indicator, cable labels, mechanical load restraint, smartphone for photos.
- Data Backup: In IndraWorks/DriveTop, read and save the drive’s motor data block and parameter set. Photograph all three connectors (power, feedback, brake) and their cable entry positions. Document the resolver and encoder cable routing — this motor has separate feedback and brake leads that get mixed up constantly.
Stage 2: Removing the Old Motor (~20 min)
- Confirm the drive is in torque-off state and the DC bus is dead. Confirm the mechanical restraint is taking the load.
- Disconnect power, feedback, and brake connectors. Label all three immediately. ⚠️ The brake connector and encoder connector sit close together on this frame — a swapped lead destroys the feedback board on power-up.
- Release the coupling or clamping set. This size runs friction-locked shaft-hub connections — use a puller, never a mallet.
- Unbolt the 4 flange bolts and withdraw the motor. Note: this frame weighs roughly 6–8 kg with the brake; support it, don’t catch it.
- Inspect the mounting face and pilot for burrs; check the new motor’s shaft sealing ring for transit damage.
- ⚠️ Keep the old motor on the bench until the replacement runs clean.
Stage 3: Installing the New Motor (~20 min)
- ESD strap on. Verify the nameplate reads MKD071B-035-KG1-KN exactly. G1 = holding brake with plain shaft; a G0 or P0 variant will not hold your vertical axis.
- Orient the connectors to match your existing cable entry before bolting the flange. Fixing this after mounting inside a machine frame is a 30-minute detour.
- Mount the motor, torque flange bolts in a cross pattern to the MKD manual spec. Apply thread-locker.
- Align the coupling; verify runout with a dial indicator — anything above 0.02 mm TIR at this torque class will eat the shaft seal within months.
- Reconnect power, feedback, and brake connectors. Route the brake lead away from the encoder cable; induced voltage on the resolver line causes phantom position faults.
- Self-Checklist: [ ] Nameplate matches, [ ] Mechanical restraint still in place, [ ] Connectors locked and labeled, [ ] Coupling aligned, [ ] Brake lead separated from feedback lead.
Stage 4: Power-On & Testing (~15 min)
- Restore the 24 V brake circuit first and confirm the brake energizes (audible click). Then restore cabinet power with the drive disabled.
- Enable the drive. Check for motor feedback or phase fault messages in the diagnostic block.
- The multiturn absolute encoder should read position immediately — no homing run. If the drive demands homing, power-cycle the drive fully with the feedback connector seated; the drive must read the motor’s data memory on first connection.
- Jog at 10% speed. Check rotation direction, listen for bearing noise, and feel the housing for abnormal vibration.
- Run a slow full-travel move, then a medium-speed move under reduced load before releasing to production.
- ⚠️ Troubleshooting Note: If the drive reports an encoder fault immediately, power off completely before reseating the feedback connector — hot-plugging it can damage the feedback electronics. Rough running means swapped motor phase leads. An axis that drifts on vertical loads means the brake release circuit is wired hot — check the brake output on the drive, not the 24 V supply.
Frequently Asked Questions (FAQ)
Q1: Can I hot-swap this motor under power?
No, and on this frame it’s even less forgiving than the smaller sizes. The IndraDrive DC bus holds lethal voltage after shutdown, the connectors aren’t rated for disconnect under load, and the 5 Nm brake releases the moment the 24 V circuit drops. On a vertical axis, that’s a dropped load. Kill power, verify the bus is below 60 V, mechanically block the load, then disconnect.
Q2: Is this model obsolete? Is what you’re selling genuinely new?
Yes — the MKD series is discontinued; Rexroth’s successor lines are MSM and MKS. Our stock is New Original / New Surplus: genuine Rexroth production, factory packaging, never placed in service. Inbound, we verify serial numbers against OEM records as an anti-counterfeit check, inspect for corrosion, rework marks, or UV yellowing, and audit for factory certificates. Photos of the exact unit with its serial number go to you before you commit.
Q3: What’s the direct replacement if this exact unit is out of stock?
Check MKD071B-035-KG1-KS (same motor, different connection housing — expect a cable set change) or the KP1 variant (keyway shaft — your plain-shaft coupling won’t fit without hardware changes). For new designs, the MSM series covers this torque class but requires a modern IndraDrive Cs/Ms converter and new cables. Call us with your drive firmware before cross-ordering; winding code 035 must match your drive’s configured motor data.
Q4: Will I lose my position data or program when I swap the motor?
No. The drive stores the motion logic and parameters. This motor’s multiturn absolute encoder holds position over 4,096 revolutions, powered and read through the feedback connector. One caveat: on first power-up after the swap, the drive needs one complete power cycle with the encoder connected to read the new motor’s data memory. Do that before enabling the axis.
Q5: Why is your price lower than Rexroth’s original list price?
Rexroth no longer manufactures it. Our stock comes from OEM spares programs, liquidated projects, and factory overruns acquired years ago. We’re not an authorized Rexroth distributor, and we state that plainly: the 12-month warranty is ours, not Rexroth’s. You’re trading factory support — on a discontinued motor — for price and immediate availability.
Q6: How important is the cooling configuration to the torque rating?
More than most engineers expect. The 8 Nm standstill figure assumes natural convection. The same motor with surface cooling or an external blower delivers up to 12 Nm — and running it hard in a sealed enclosure without airflow means you’re really getting the lower number while the thermal model in your drive thinks otherwise. If your original installation used a blower kit, make sure it’s reinstalled. Overtemperature faults three months after a “like-for-like” swap almost always trace back to a missing blower.
Q7: What quality checks do you run before shipping?
Every unit passes inbound inspection (serial verification, anti-counterfeit screening, visual condition and accessory audit), then a live bench test on a genuine IndraDrive rack: power-up sequence, resolver/encoder handshake, brake release and engage test, insulation resistance check (500 V Megger, >10 MΩ), and a continuous burn-in exceeding 24 hours with thermal monitoring. Results are logged in a signed Test Report; the unit ships in ESD bagging with a QC Passed label and date. Test videos and photos are available on request. We won’t claim it’s failure-proof — we’ll tell you exactly what we verified.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626