Description
Core Product Summary
The Bosch Rexroth SE352 is a control unit for the Rexroth Tightening System 350. It controls and monitors up to two independent tightening channels, supplying control signals to two servo amplifiers and their associated tightening spindles or ErgoSpin hand-held nutrunners. The SE352 order number is 0 608 830 262.
The unit is designed for installation in a BT356 card rack or SB35x system box. It provides two USB 2.0 host interfaces, a USB device interface for programming and parameterization, a slot for CF350 mass storage, and status LEDs with a reset button for tightening channels 1 and 2. Tightening programs and rework strategies are configured through the BS350 operating program.
Key Technical Specifications
| Item | Specification |
|---|---|
| Manufacturer / model | Bosch Rexroth SE352 |
| Order number | 0 608 830 262 |
| Product type | Tightening control unit |
| System family | Rexroth Tightening System 350 |
| Tightening channels | Up to 2 independent channels |
| Servo amplifier control | 2 servo amplifiers |
| Compatible tightening tools | Tightening spindles or ErgoSpin hand-held nutrunners |
| Installation location | BT356 card rack or SB35x system box |
| USB host interfaces | 2 × USB 2.0, type A (X3U1, X3U2) |
| USB device interface | USB 2.0-compatible, type B (X3U3), maximum data rate 3 Mbit/s |
| USB host supply | 5 V DC / 0.5 A per host interface |
| Mass storage | CF350 in slot X6C1 |
| Front-panel indicators | LEDs for tightening channels 1 and 2; reset button |
| Operating ambient temperature | Up to 60 °C |
| Operating relative humidity | 20% to 90%, non-condensing |
| Storage temperature | -20 to 70 °C |
| Storage relative humidity | 20% to 95% |
| Protection class | IP20 (approximately NEMA 1) |
| Dimensions (W × H × D) | 24.5 × 271 × 285 mm |
| Weight | 1.4 kg without modules |
Detailed Product Overview
The Bosch Rexroth SE352 is the two-channel tightening controller within the modular Rexroth Tightening System 350. It generates the control signals for two servo amplifiers, which in turn operate tightening spindles or ErgoSpin hand-held nutrunners. The two channels can be assigned independently, allowing one SE352 to serve two tightening positions.
The controller performs system diagnosis and monitors the components of each tightening channel. Tightening processes and rework strategies are programmed in the BS350 operating program. The unit also supports automatic component recognition, which is used during system start-up.
The SE352 includes two USB 2.0 type-A host ports, a USB type-B device port for connection to a programming PC, and an X6C1 slot for Rexroth CF350 mass storage. The USB device interface is specified for a maximum data rate of 3 Mbit/s. The front panel provides LEDs for each tightening channel and a reset button: a brief press initiates a software reset, while a press longer than three seconds resets both the controller and its two servo amplifiers.
The SE352 is a system component rather than a standalone machine. It must be installed in a BT356 card rack or SB35x system box and integrated into a complete machine or tightening system. For multi-channel systems, a KE350 or KE350G IL communication unit coordinates the individual control units and handles communication with external systems such as a PLC or central computer.
The controller contains a battery-buffered SRAM that retains tightening-result data during power loss; the battery also supplies the system clock. The documented recommended replacement battery is a 3 V CR2450 lithium cell with a capacity of at least 560 mAh.

SE352

SE352
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| System family | Rexroth Tightening System 350 | The SE352 is a modular-system control unit |
| Mounting platform | BT356 card rack or SB35x system box | Insert into the designated slot and secure with the front knurled bolts |
| Servo amplifiers | LTS350D or LTE350D | The SE352 controls up to two servo amplifiers |
| Tightening tools | Tightening spindles or ErgoSpin hand-held nutrunners | One tightening channel serves one spindle or nutrunner |
| Multi-channel operation | KE350 or KE350G IL communication unit | Required for use in multi-channel tightening systems |
| Programming | BS350 operating program | Used to configure interfaces, assign control signals, and program tightening processes |
| Programming connection | USB device interface X3U3 | Type B, USB 2.0-compatible, maximum data rate 3 Mbit/s |
| Mass storage | Rexroth CF350 | Insert into X6C1 with the plug-in connections facing forward |
| Interface module | IM24V, order number 0 608 830 259 | Compatible with the SE352M B1 slot; not documented as installable in the SE352 |
| Firmware | Firmware used in the existing system | Required when installing the unit as a replacement or extension |
| Battery | 3 V CR2450 lithium cell, capacity at least 560 mAh | Battery-buffered SRAM stores tightening results and supplies the system clock |
Dimensions, Mounting & Connection Notes
The SE352 measures 24.5 mm wide, 271 mm high, and 285 mm deep, and weighs 1.4 kg without modules. Its protection class is IP20, approximately equivalent to NEMA 1, so it must be installed within the protected enclosure provided by the BT356 card rack or SB35x system box.
Installation requires the power supply to the card rack or system box to be switched off, followed by a 10-second discharge period. Insert the unit into its designated slot, then tighten the front knurled bolts until the front panel is flush with the rack or system box. The same power-off and discharge procedure applies before removal.
The controller provides two USB type-A host ports, a USB type-B device port, and an X6C1 slot for CF350 mass storage. During installation, use ESD precautions and ensure that unused slots are closed with the appropriate dummy panels. Before start-up, check that all connectors are firmly fitted and that the battery is correctly seated.
FAQ
What is the Bosch Rexroth SE352?
It is a two-channel control unit for the Rexroth Tightening System 350, used to control and monitor tightening spindles or ErgoSpin hand-held nutrunners through servo amplifiers.
What is the order number for the SE352?
The SE352 order number is 0 608 830 262.
How many tightening channels does it control?
It controls up to two independent tightening channels, each with its own servo amplifier.
Where is the SE352 installed?
It is installed in a Rexroth BT356 card rack or SB35x system box.
What interfaces does the SE352 provide?
It provides two USB 2.0 type-A host interfaces, a USB 2.0-compatible type-B device interface for programming, and an X6C1 slot for CF350 mass storage.
What software is used to configure it?
The BS350 operating program is used to configure interfaces, assign control signals, and program tightening processes and rework strategies.
Can the SE352 accept an IM24V interface module?
The documented B1 interface-module slot is provided on the SE352M variant. The IM24V module provides 10 inputs and 13 outputs and is documented for installation in the SE352M, KE350, KE350G IL, or CS351 Compact System.
What battery does it use?
It uses a 3 V CR2450 lithium battery with a recommended capacity of at least 560 mAh. The battery retains SRAM data and supplies the system clock during power loss.
Documented Performance Data
| Metric | Value / Range | Test / Operating Condition |
|---|---|---|
| Tightening channels controlled | Up to 2 | One SE352 control unit |
| USB device-interface data rate | 3 Mbit/s maximum | USB device interface X3U3 |
| USB host supply | 5 V DC / 0.5 A | Each USB type-A host interface |
| Operating ambient temperature | Up to 60 °C | SE352 / SE352M control unit |
| Operating relative humidity | 20% to 90%, non-condensing | SE352 / SE352M control unit |
| Reset behavior | Software reset below 1 second; hardware reset above 3 seconds | Reset button; hardware reset also resets the two corresponding servo amplifiers |

WhatsApp: +86 16626708626