Sale!

Bosch Rexroth TVM2.4-050-220300-W1 Indramat TVM Power Supply Module

The Bosch Rexroth Indramat TVM2.4-050-220300-W1 is a modular power supply unit from the TVM series. It converts three-phase AC input into a regulated DC bus voltage for supplying Indramat/Rexroth servo drive systems.

Categories: , , , , SKU: TVM2.4-050-220300-W1 Brand:

Description

Core Product Summary

The Bosch Rexroth Indramat TVM2.4-050-220300-W1 is a modular power supply unit from the TVM series. It converts three-phase AC input into a regulated DC bus voltage for supplying Indramat/Rexroth servo drive systems.

It accepts a three-phase 220 V AC input (50–60 Hz) and delivers a nominal 300 V DC bus at a type current of 50 A. Continuous DC bus power is 7.5 kW with peak capability of 60 kW. The unit incorporates a built-in blower for cooling and is designed for vertical mounting in industrial control cabinets. It provides auxiliary control voltages and supports dynamic braking functions for connected drives.

Key Technical Specifications

Parameter Value
Manufacturer Bosch Rexroth / Indramat
Series TVM 2.4 Power Supply Module
Type current 50 A
Three-phase input voltage AC 220 V, 50–60 Hz
Nominal DC bus voltage DC 300 V
Continuous DC bus power 7.5 kW
Peak DC bus power 60 kW
Cooling method Built-in blower (W1)
Configuration 4
Protection rating IP10
Operating temperature 5 to 45 °C
Storage temperature −30 to 85 °C
Weight 15 kg
Mounting Vertical

Detailed Product Overview

The TVM2.4-050-220300-W1 belongs to the Indramat TVM family of modular power supplies used to feed DC bus power to multiple servo drive controllers. It rectifies and regulates three-phase AC mains into a stable 300 V DC bus, enabling coordinated operation of Indramat or Bosch Rexroth drive systems.

The module is rated for a continuous type current of 50 A and delivers 7.5 kW continuous DC bus power, with short-term peak capability reaching 60 kW. An integrated blower provides forced-air cooling to maintain thermal limits under load. Configuration level 4 indicates the specific hardware revision and feature set of this generation.

Auxiliary outputs supply control electronics (typically including 24 V and ±15 V rails). Diagnostic LEDs and a fault-reset function support rapid troubleshooting. The unit includes protection against overcurrent, overvoltage, and related fault conditions, and can initiate dynamic braking of connected drives when required.

The compact form factor and vertical mounting orientation are intended for installation in standard industrial control cabinets. Proper clearance for airflow and correct mains fusing are required for reliable operation.

TVM2.4-050-220300-W1

TVM2.4-050-220300-W1

TVM2.4-050-220300-W1

TVM2.4-050-220300-W1

Dimensions, Mounting & Connection Notes

  • Weight: 15 kg
  • Mounting orientation: Vertical
  • Protection rating: IP10
  • Cooling: Internal blower — maintain free airflow paths
  • Typical clearances: Allow adequate space above and below the unit for ventilation (exact values depend on cabinet design)
  • Connections: Three-phase AC input, DC bus output terminals (L+/L−), PE grounding, and auxiliary control voltage terminals

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Drive system Indramat / Bosch Rexroth servo drives Supplies DC bus power to compatible TVM-series drive controllers
Input supply Three-phase AC 220 V, 50–60 Hz Tolerance typically ±10–15 % (confirm exact limits for the installed unit)
DC bus Nominal 300 V DC Connects via L+ / L− terminals to drive modules
Cooling Built-in blower Ensure unobstructed airflow; vertical mounting required
Control voltages Auxiliary outputs (24 V / ±15 V range) Used for drive electronics and logic
Mounting Vertical cabinet mounting Observe manufacturer clearance recommendations

FAQ

What is the TVM2.4-050-220300-W1?
It is a Bosch Rexroth Indramat modular power supply that converts three-phase 220 V AC into a 300 V DC bus for supplying servo drive systems.

What is the rated current and power?
Type current is 50 A. Continuous DC bus power is 7.5 kW; peak power is 60 kW.

What input voltage does it require?
Three-phase AC 220 V at 50–60 Hz.

How is the unit cooled?
It uses a built-in blower (designated by the W1 suffix).

What is the nominal DC bus voltage?
300 V DC.

What is the protection rating?
IP10.

What is the approximate weight?
15 kg.

In which orientation must it be mounted?
Vertical mounting is required.