Description
Core Product Summary
The B&R X20AT6402 is a temperature input module designed for the X20 System, providing six dedicated thermocouple inputs. It is engineered to acquire high-resolution temperature data directly from J, K, N, S, B, and R type sensors, making it suitable for multi-point thermal monitoring in industrial automation architectures.
This module features a 16-bit sigma-delta converter with configurable output resolution of 0.1°C or 0.01°C. It includes integrated internal terminal temperature compensation and configurable input filters (15 Hz to 1000 Hz) to suppress electrical noise. The module requires a compatible X20 bus module and a 12-pin X20TB12 terminal block for operation, and it holds CE, UKCA, ATEX Zone 2, cULus, and multiple marine certifications.
Key Technical Specifications
| Parameter | Verified Specification |
|---|---|
| Module Type | X20 temperature input module |
| Input Channels | 6 thermocouple inputs |
| Supported Sensor Types | J, K, N, S, B, R (EN 60584) |
| Digital Converter Resolution | 16-bit (Sigma-delta) |
| Output Resolution | Configurable to 0.1°C or 0.01°C (Raw value: 1 µV or 2 µV) |
| Conversion Time | 80.4 ms (1 channel, 50 Hz filter); (n + 1) × 40.2 ms (n channels) |
| Input Filter | Configurable from 15 Hz to 1000 Hz (1 ms to 66.7 ms) |
| Terminal Temperature Compensation | Internal (integrated) |
| Electrical Isolation | Channel isolated from bus; channels not isolated from each other |
| Insulation Voltage | 500 Veff (between channel and bus) |
| Power Consumption | 0.01 W (Bus), 0.91 W (Internal I/O) |
| Certifications | CE, UKCA, ATEX Zone 2, cULus, HazLoc, DNV, ABS, BV, LR, KR, CCS |
Engineering Selection Highlights
- High-Density Acquisition: Provides six thermocouple channels within a single 12.5 mm module pitch, optimizing control cabinet space for multi-point temperature monitoring.
- Flexible Noise Suppression: Configurable input filters (15 Hz to 1000 Hz) allow engineers to target and suppress specific environmental noise, such as 50 Hz or 60 Hz mains interference.
- Integrated Cold Junction Compensation: The built-in terminal temperature compensation eliminates the need for external reference junction hardware in standard applications.
- External Cold Junction Support: Function model 1 allows an external cold junction temperature value to be predefined, improving measurement precision in applications with high thermal gradients or long copper wire runs.
- Comprehensive Diagnostics: Continuous monitoring for open circuits, range undershoot, and range overshoot, with status reported via local LEDs and mapped to controller registers.

X20AT6402
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| System Family | B&R X20 System | Must be mounted on an X20 bus segment. |
| Mandatory Bus Module | X20BM11 or X20BM15 | Required to provide bus communication and internal I/O power. |
| Mandatory Terminal Block | X20TB12 | 12-pin, 24 VDC keyed terminal block required for field wiring. |
| Engineering Software | B&R Automation Studio | Requires the appropriate hardware support package (HW Upgrade) for configuration. |
| Sensor Compatibility | J, K, N, S, B, R thermocouples | Complies with EN 60584 sensor standards. |
Dimensions, Mounting & Connection Notes
- Module Pitch: 12.5 mm (+0.2 mm tolerance).
- Mounting Orientation: Supported in both horizontal and vertical orientations.
- Operating Temperature: -25 to 55°C (horizontal, Revision ≥M3); -25 to 50°C (vertical).
- Installation Elevation: No limitation up to 2000 m. Above 2000 m, ambient temperature must be reduced by 0.5°C per 100 m.
- Degree of Protection: IP20.
- Connection Method: Pluggable 12-pin terminal block (X20TB12, ordered separately).
- Wiring Note: For ceramic heating elements with integrated thermoelements, connecting the thermocouple minus input to the power supply module’s minus input is recommended to prevent ripple voltage measurement errors.
Detailed Product Overview
The B&R X20AT6402 is a specialized temperature input module engineered for the X20 distributed I/O system, providing six channels for direct thermocouple measurement. In industrial automation architectures, acquiring temperature data traditionally requires external transmitters to convert millivolt signals into standard analog formats. This module integrates that functionality directly into the I/O rack, reducing component count, wiring complexity, and potential points of failure.
The core of the module’s measurement capability is a 16-bit sigma-delta analog-to-digital converter. It supports standard thermocouple types J, K, N, S, B, and R, complying with EN 60584. Engineers can configure the output resolution to either 0.1°C or 0.01°C depending on the precision required by the application. For specialized diagnostics or custom sensor types, the module also offers a direct raw value output mode with 1 µV or 2 µV resolution, bypassing internal linearization.
Signal integrity is managed through configurable first-order low-pass input filters. The filter time can be set between 1 ms and 66.7 ms (corresponding to cutoff frequencies from 1000 Hz down to 15 Hz). This flexibility allows engineers to suppress specific environmental noise, such as 50 Hz or 60 Hz mains interference, which is critical in electrically noisy industrial environments. The conversion time scales predictably based on the number of active channels and the selected filter time, allowing for deterministic I/O update cycles.
A critical factor in thermocouple measurement is cold junction compensation. The X20AT6402 features integrated internal terminal temperature compensation, which automatically corrects for the temperature at the wiring terminal. For applications demanding higher precision, or where the module is subjected to significant thermal gradients (such as proximity to high-power components), the module supports an external cold junction input. By reading an external temperature value via the controller, the X20AT6402 can apply a unified compensation value across all channels, improving overall measurement accuracy.
Electrical isolation is maintained between the measurement channels and the system bus (500 Veff), preventing ground loops from affecting the broader control network, though individual channels are not isolated from each other. Comprehensive diagnostics continuously monitor for open circuits, range undershoot, and range overshoot. These conditions are indicated by local LED status lights and mapped to specific error codes in the controller’s memory, enabling rapid troubleshooting.
For system integration, the module requires a compatible X20 bus module to establish communication and a 12-pin X20TB12 terminal block for field wiring. It is designed for operation in demanding environments, holding ATEX Zone 2, cULus, HazLoc, and multiple marine certifications, making it suitable for both standard factory floors and regulated hazardous or maritime installations.
Applications & System Role
The B&R X20AT6402 serves as a dedicated temperature acquisition slice within the X20 distributed I/O architecture. Its primary role is to digitize millivolt-level signals from standard thermocouple sensors, eliminating the need for standalone temperature transmitters. This makes it specifically suited for applications such as industrial oven monitoring, plastics extrusion, HVAC systems, and process heating, where multi-point temperature data must be processed directly by the central controller via the X20 backplane.
FAQ
Q: What is the B&R X20AT6402?
A: The B&R X20AT6402 is a temperature input module for the X20 System, providing six dedicated inputs for thermocouple sensors.
Q: Which thermocouple types are supported by this module?
A: It supports type J, K, N, S, B, and R thermocouples in accordance with the EN 60584 standard.
Q: What is the measurement resolution of the X20AT6402?
A: The output resolution is software-configurable to either 0.1°C or 0.01°C. A raw value mode is also available with 1 µV or 2 µV resolution.
Q: Does the module require external cold junction compensation hardware?
A: No, it features integrated internal terminal temperature compensation. However, it also supports an external cold junction temperature input via software configuration for applications requiring higher precision.
Q: How can electrical noise be managed with this module?
A: The module includes a configurable first-order low-pass input filter. The filter time can be set between 1 ms and 66.7 ms (15 Hz to 1000 Hz) to suppress specific interference frequencies.
Q: What mandatory accessories are required to install the X20AT6402?
A: Installation requires one X20 bus module (such as X20BM11 or X20BM15) and one 12-pin X20TB12 terminal block, both of which are ordered separately.
Q: Is the X20AT6402 certified for hazardous or marine environments?
A: Yes, it holds ATEX Zone 2, cULus, and HazLoc certifications, along with marine approvals from DNV, ABS, BV, LR, KR, and CCS.