Description
Core Product Summary
The B&R X20PS9400 is a 24 VDC power supply module for the X20 System. It supplies an X20 bus controller, the X2X Link power supply, and the internal I/O supply. The module is intended for use together with an X20 bus controller and provides 7 W nominal output power for the bus controller and X2X Link supply.
The X20PS9400 accepts 24 VDC input with a tolerance of −15% to +20%, has an integrated non-replaceable fuse, reverse-polarity protection, and short-circuit-proof, temporary-overload behavior. It supports parallel connection and redundant operation when multiple supply modules operate simultaneously. An RS232 service interface with a maximum transfer rate of 115.2 kbit/s is integrated for configuration and diagnostic access.
Key Technical Specifications
| Category | Specification |
|---|---|
| Product type | X20 power supply module |
| Function | Supplies bus controller, X2X Link power supply, and internal I/O supply |
| Input voltage | 24 VDC, −15% / +20% |
| Input current | Maximum 0.7 A |
| Input fuse | Integrated; cannot be replaced |
| Reverse-polarity protection, supply input | Yes |
| Bus controller / X2X Link output power | 7 W nominal |
| Parallel connection | Yes |
| Redundant operation | Yes, with multiple supply modules operating simultaneously |
| Overload behavior | Short-circuit proof; temporary overload |
| Internal I/O power consumption | 0.6 W |
| X2X Link power consumption | 1.42 W |
| Input I/O power supply voltage | 24 VDC, −15% / +20% |
| Required input I/O line fuse | Maximum 10 A, slow-blow |
| Reverse-polarity protection, I/O supply | No |
| Output I/O nominal voltage | 24 VDC |
| Output I/O permissible contact load | 10 A |
| Short-circuit behavior, output I/O | Requires a line fuse |
| Service interface | 1 × RS232 |
| RS232 transfer rate | Maximum 115.2 kbit/s |
| Status indication | Overload, operating status, module status, and RS232 |
| Diagnostics | Module run/error via LED and software; RS232 data transfer via LED |
| Electrical isolation | Feed isolated from bus controller / X2X Link supply; I/O supply not isolated from I/O power supply; RS232 not isolated from bus |
| Module pitch | 12.5 + 0.2 mm |
| Degree of protection | IP20 |
| Approvals | CE, UKCA, ATEX Zone 2, cULus, cCSAus HazLoc, DNV, CCS, LR, KR, EAC, KC |
Engineering Selection Highlights
- The X20PS9400 is a system power supply for an X20 bus controller, so it is selected as part of an X20 bus-controller I/O station rather than as a standalone power supply.
- Its 7 W nominal output supplies the bus controller and X2X Link power section; total X2X Link power demand must remain within this rating.
- Parallel connection and redundant operation are supported when multiple supply modules run simultaneously, allowing a redundant bus-controller/X2X Link supply arrangement.
- The module’s 24 VDC input has integrated reverse-polarity protection and a non-replaceable internal fuse.
- The I/O power-supply section requires an external maximum 10 A slow-blow line fuse and does not include reverse-polarity protection.
- The integrated RS232 service interface provides a direct service connection at up to 115.2 kbit/s.
- An X20 bus base and X20TB12 terminal block are required and ordered separately.

X20PS9400
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Automation system | B&R X20 System | The module is an X20 system module for bus-controller installations. |
| Bus controller | Used together with an X20 bus controller | The module supplies the bus controller and X2X Link power. |
| Bus base | 1 × X20BB8x bus base required | Order the appropriate X20BB8x bus base separately. |
| Terminal block | 1 × X20TB12, 12-pin terminal block required | Order separately; used for the RS232 service interface connection. |
| Supply input | 24 VDC, −15% / +20% | Integrated fuse and reverse-polarity protection are provided. |
| I/O supply input | 24 VDC, −15% / +20% | Requires an external maximum 10 A slow-blow line fuse. |
| X2X Link supply | 7 W nominal output power | Verify connected bus-controller and X2X Link power demand against this rating. |
| Redundancy | Multiple supply modules may operate simultaneously | Enables a redundant bus-controller / X2X Link supply arrangement. |
| Service connection | via X20TB12 | Maximum transfer rate is 115.2 kbit/s. |
Dimensions, Mounting & Connection Notes
| Item | Verified data |
|---|---|
| Module pitch | 12.5 + 0.2 mm |
| Mounting orientation | Horizontal or vertical |
| Operating temperature, horizontal | −25 to 60°C |
| Operating temperature, vertical | −25 to 50°C |
| Installation altitude | No limitation from 0 to 2,000 m; above 2,000 m, reduce ambient temperature by 0.5°C per 100 m |
| Degree of protection | IP20 |
| Required bus base | 1 × X20BB8x, ordered separately |
| Required terminal block | 1 × X20TB12, 12-pin, ordered separately |
| Service interface connection | RS232 via 12-pin X20TB12 terminal block |
| Input fuse | Integrated and non-replaceable |
| I/O supply fuse | External maximum 10 A slow-blow line fuse required |
Detailed Product Overview
The B&R X20PS9400 is a 24 VDC supply module for X20 bus-controller systems. It provides power for the bus controller, the X2X Link power supply, and the internal I/O supply. The module is intended to be installed with an X20 bus controller and an X20BB8x bus base, both of which are part of the X20 system architecture.
The bus-controller and X2X Link supply section accepts 24 VDC with a tolerance of −15% to +20% and draws up to 0.7 A. It provides 7 W nominal output power. The module includes an integrated, non-replaceable fuse and reverse-polarity protection on this supply input. Its overload behavior is documented as short-circuit proof with temporary overload capability.
The X20PS9400 supports parallel connection and redundant operation. Multiple supply modules can operate simultaneously to provide redundancy for the bus-controller and X2X Link supply. This makes the module relevant to X20 installations where the local bus-controller power arrangement is designed with a redundant supply path.
The module also includes an I/O power-supply section. Its input accepts 24 VDC with the same −15% to +20% tolerance, but it requires an external slow-blow line fuse rated at a maximum of 10 A and does not provide reverse-polarity protection. The output I/O supply provides 24 VDC with a permissible contact load of 10 A; a line fuse is required for short-circuit behavior in this section.
An RS232 service interface is integrated for configuration and diagnostic access. It connects through the 12-pin X20TB12 terminal block and supports a maximum transfer rate of 115.2 kbit/s. The module provides status indication for overload, operating status, module status, and RS232 activity, with module run/error diagnostics available through both LED indication and software.
The X20PS9400 is an IP20 module with a 12.5 + 0.2 mm pitch. It can be mounted horizontally or vertically; the permitted operating temperature is −25 to 60°C horizontally and −25 to 50°C vertically. At elevations above 2,000 m, the allowable ambient temperature is reduced by 0.5°C for every additional 100 m.
The module carries CE and UKCA approvals and is documented with ATEX Zone 2, cULus industrial control equipment, and cCSAus hazardous-location process control equipment approvals. Additional marine and regional approvals include DNV, CCS, LR, KR, EAC, and KC. Approval applicability should be reviewed against the complete X20 installation and applicable system documentation.
Applications & System Role
The X20PS9400 is the power-distribution module for an X20 bus-controller I/O station. It provides the feed required by the bus controller, powers the X2X Link supply, and supplies the internal I/O power section for the connected X20 I/O architecture.
Its 7 W nominal bus-controller/X2X Link output is the key sizing parameter for the local bus-controller and X2X Link power demand. Where supply continuity is required, multiple X20PS9400 modules can operate in parallel to provide a redundant bus-controller and X2X Link supply arrangement.
The integrated RS232 service interface provides a local service connection for configuration and diagnostics. The module is therefore positioned between the incoming 24 VDC supply and the X20 bus controller, supplying and protecting the power paths required for the local X20 I/O station.
FAQ
What is the B&R X20PS9400?
The B&R X20PS9400 is a 24 VDC power supply module for the B&R X20 System. It supplies an X20 bus controller, the X2X Link power supply, and the internal I/O supply.
What output power does the X20PS9400 provide?
It provides 7 W nominal output power for the bus controller and X2X Link power supply.
Can the X20PS9400 be used redundantly?
Yes. Multiple supply modules can operate simultaneously to support a redundant bus-controller and X2X Link supply arrangement.
What input voltage does the X20PS9400 require?
The supply input requires 24 VDC with a tolerance of −15% to +20% and draws up to 0.7 A.
Does the module include protection features?
Yes. The bus-controller/X2X Link supply input has an integrated non-replaceable fuse, reverse-polarity protection, short-circuit-proof behavior, and temporary overload capability.
What service interface is included?
The module includes one RS232 service interface, connected through an X20TB12 terminal block, with a maximum transfer rate of 115.2 kbit/s.
Which accessories are required for installation?
The module requires one X20BB8x bus base and one 12-pin X20TB12 terminal block; both are ordered separately.
What are the operating temperature limits?
The module operates from −25 to 60°C when mounted horizontally and −25 to 50°C when mounted vertically. Storage and transport temperatures are −40 to 85°C.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626