Sale!

CONSILIUM NSAC-1 Marine Fire Alarm Control System

  • Model: NSAC-1
  • Brand: Consilium (Salwico)
  • Series: Salwico NSAC Marine Fire Alarm System
  • Core Function: Monitors addressable fire loops and controls marine alarm signalling.
  • Product Type: Marine Fire Alarm Control Panel
  • Key Specs: 230 VAC / 24 VDC supply | LFNet distributed networking | Analog addressable detection
  • Condition: New Original / New Surplus (Never refurbished).
  • Inventory Status: Legacy strategic maintenance unit; essential safety stock for vessel class maintenance and SOLAS compliance.
Categories: , , , , , SKU: NSAC-1 Brand:

Description

Key Technical Specifications

Parameter Value
Manufacturer Consilium Marine AB
Brand / Family Consilium / Salwico
Model NSAC-1
Equipment Category Marine Fire Alarm Control Panel
Mains Input Power 230 VAC ±10%, 50/60 Hz
Internal Loop / Auxiliary Power 18.5 to 36 VDC (24 VDC nominal)
Backup Battery Power 24 VDC lead-acid battery backup array
System Networking LFNet distributed marine network protocol
Serial Interfaces RS-232 / RS-422 communications port
Conventional Integration Compatible via ZC10 conversion circuit board
Operating Temperature 0 to 60°C
Protection Rating IP-rated heavy-duty marine enclosure

 

Product Introduction & Supply Chain Strategy

The Consilium NSAC-1 is a marine-grade addressable fire alarm control system designed to supervise detector loops, process smoke/thermal alarm signals, and trip vessel fire suppression relays. Engineered for commercial marine vessels, offshore platforms, and naval installations, it integrates seamlessly into Salwico LFNet networks to maintain continuous hazard monitoring across multiple shipboard fire zones.

Acquiring the NSAC-1 panel as New Surplus provides a crucial lifeline for legacy fleet vessels seeking to maintain Class approval without undergoing expensive whole-ship re-cabling. Installing refurbished or pulled safety hardware introduces unacceptable failure risks, including corroded backplanes, failed backup charging circuits, or micro-cracked relay contacts. Stocking genuine, unused surplus panels secures immediate drop-in replacement capability, avoiding severe port-state detention risks and high downtime costs.

NSAC-1

NSAC-1

NSAC-1

NSAC-1

Installation & Configuration Guide

1.Pre-Installation (Prep & Safety):Estimated time: 15 mins.

Isolate main vessel power to the fire safety cabinet and disconnect backup battery leads to avoid arc flash or board damage. Put on a grounded ESD wrist strap. Document all DIP-switch configurations, record terminal numbers for loop conductors, and verify zero voltage across all bell circuit leads.

2.Removal:Estimated time: 10 mins.

Disconnect field loop cables, LFNet communication connectors, and relay terminal blocks carefully. Loosen chassis retaining fasteners and remove the legacy NSAC-1 mainboard chassis without flexing internal connectors.

3.Installation (Clone & Seat):Estimated time: 15 mins.

Set the address DIP switches and configuration jumpers on the replacement NSAC-1 unit to mirror the removed board exactly. Mount the panel securely into the marine enclosure backplate, ensuring solid frame grounding to protect against high-EMC vessel environments. Reattach all wiring blocks securely.

4.Power-On & Testing:Estimated time: 20 mins.

Reconnect 24 VDC battery supply followed by 230 VAC mains power. Verify that power LEDs initialize to normal status without earth-fault or loop-fault warnings. Execute a manual loop test to confirm communication handshakes across all connected detectors and alarm sounders.

 

Firmware/Software Versions & Upgrade Notes

  • Recommended Version: Match system firmware and network protocol revisions to your vessel’s existing Salwico LFNet matrix to prevent topology polling errors.
  • Compatibility Notes: The NSAC-1 natively supports Salwico addressable detector loops. Integrating older conventional zones requires the ZC10 interface board with properly rated end-of-line (EOL) resistors.
  • Risk Management: Never flash firmware or alter EEPROM settings while the vessel is at sea without secondary safety watches in place. Performing direct drop-in hardware swaps with matched factory firmware preserves established zone mapping and classification compliance.

 

Frequently Asked Questions (FAQ)

Is this Consilium NSAC-1 unit genuinely new or refurbished?

This product is a Brand New Surplus unit. It features original OEM packaging, zero pin wear, and has never been commissioned on an active vessel. We strictly reject second-hand, pulled, or repaired marine safety electronics.

Why is buying New Surplus vital for marine fire alarm systems?

Marine environments present severe humidity, vibration, and salt-fog conditions. Used or refurbished safety panels often harbor latent corrosion or degraded relay contacts that can cause false alarms or total detection failure during an emergency. Sourcing New Surplus guarantees factory-level reliability and maintains vessel safety integrity.

Can the NSAC-1 integrate with legacy conventional fire detectors?

Yes. The NSAC-1 supports conventional detector integration when fitted with the dedicated ZC10 circuit module, allowing vessel engineers to bridge older detection zones into the main addressable controller.

What power input does this control panel require?

The panel operates on standard marine 230 VAC (50/60 Hz) primary power alongside a redundant 24 VDC backup battery array to ensure uninterrupted protection during main switchboard blackouts.

What warranty coverage is provided with this unit?

Every NSAC-1 unit is backed by a comprehensive 1-year replacement warranty, giving ship operators OEM-grade assurance along with off-the-shelf dispatch to meet tight port turnaround schedules.