Description
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Duelco A/S |
| Model | NST-2004 |
| Device type | Emergency-stop safety relay |
| Safety input applications | E-stop switches, safety doors, light curtains, magnetic switches |
| Supply voltage variants | 24 VDC; 8–36 VDC; 230 VAC, depending on version |
| Safety outputs | 3 normally open (NO) safety contacts and 1 normally closed (NC) contact, depending on variant |
| PLC monitoring | Transistor monitoring output on applicable versions |
| AC-15 switching rating | 230 V / 5 A |
| DC-13 switching rating | 24 V / 5 A |
| Maximum switching capacity | 1,380 VA for resistive loads, as specified in the datasheet |
| Emergency-stop cutout time | Less than 30 ms for relay K1 |
| Reactivation time | Approximately 0.5 s after emergency-stop release |
| Mechanical lifetime | More than 10 million operations |
| Mounting | DIN rail, snap-on mounting |
| Dimensions (W × H × D) | 22.5 × 114.5 × 99 mm |
| Weight | Approximately 200 g for DC versions; 250 g for AC versions |
| Operating temperature | −25°C to +60°C |
| Storage temperature | −30°C to +70°C |
| Enclosure protection | IP20 terminals; IP40 housing |
| Safety standard reference | EN ISO 13849-1; manufacturer documentation lists PL e / Category 4 |
Specifications are based on Duelco’s NST-2004 datasheet. Ratings and output arrangements must be checked against the exact version being installed.
Product Introduction
The DUELCO NST-2004 provides safety-relay functionality for machinery that requires monitored emergency-stop circuits or protective-device interlocking. It can be used with compatible safety switches, light curtains, and guard-door contacts. Its relay outputs are intended for integration into a properly designed safety circuit, while the monitoring output on applicable variants can provide status information to a PLC. The correct version must be selected according to supply voltage, input configuration, reset requirements, and the machine’s validated safety architecture.

NST-2004

NST-2004
Installation & Configuration Guide
Verify the exact variant
Duelco lists several NST-2004 versions:
| Variant | Article number | Supply |
|---|---|---|
| NST-2004F | 42010204 | 24 VDC |
| NST-2004D | 42011204 | 24 VDC |
| NST-2004F | 42010205 | 8–36 VDC |
| NST-2004F | 42012301 | 230 VAC |
Confirm the installed relay’s nameplate and article number. Do not select a replacement based on the NST-2004 family name alone.
Isolate the machine
- Place the machine in a safe state and apply the site’s lockout/tagout procedure.
- Isolate control power and any external energy sources that could cause hazardous movement.
- Ensure that the safety circuit cannot be inadvertently re-energized during maintenance.
Check the safety circuit
- Verify the wiring diagram for the E-stop switches, guard interlocks, or light curtains.
- Confirm the required two-channel monitoring arrangement and reset method.
- Check whether the application requires short-circuit monitoring or external contactor feedback.
- Verify the output contact ratings against the connected load and applicable utilization category.
Mount and wire the relay
- Install the relay on the specified DIN rail.
- Use the exact terminal assignments in the manufacturer’s wiring diagram.
- Keep safety outputs separate from PLC status signals where the circuit design requires it.
- Do not rely on a PLC monitoring signal as a substitute for the relay’s safety outputs.
Validate safety operation
- Perform commissioning and validation according to the machine’s risk assessment and approved safety design.
- Test emergency-stop activation, protective-device interruption, reset behavior, and external contactor monitoring where applicable.
- Verify that the machine cannot restart unexpectedly after a safety demand.
- Record the test results and return the equipment to service only after the required safety checks pass.
Safety warning: The NST-2004 is a safety-related component. Installation, replacement, and validation must be performed by qualified personnel. Follow the official manual and the machine’s validated safety design; do not bypass safety contacts or defeat protective devices during troubleshooting.
Frequently Asked Questions
Q1: What is the DUELCO NST-2004 used for?
It is an emergency-stop safety relay used to monitor compatible safety devices, including E-stop switches, light curtains, safety doors, and magnetic switches.
Q2: What supply voltage does the NST-2004 require?
The product family includes 24 VDC, 8–36 VDC, and 230 VAC variants. The correct voltage depends on the complete model suffix and article number.
Q3: Does the NST-2004 have a PLC monitoring output?
The manufacturer describes a transistor output for PLC monitoring on applicable versions. This status output should not replace the safety relay’s designated safety contacts.
Q4: What is the emergency-stop response time?
The datasheet specifies a cutout time of less than 30 ms for relay K1. Confirm the exact variant and conditions in the applicable technical documentation.
Q5: Is the NST-2004 suitable for safety-critical applications?
The manufacturer’s documentation references EN ISO 13849-1 and Performance Level e / Category 4. The achieved safety performance depends on the complete safety system, wiring, component selection, validation, and application design—not the relay alone.
Q6: Can NST-2004F replace NST-2004D?
Do not assume interchangeability. Verify the supply, contact arrangement, reset behavior, monitoring output, and terminal configuration against the manufacturer documentation for both variants.
Q7: What should be checked before purchasing a replacement?
Confirm the full model suffix, article number, supply voltage, terminal diagram, output arrangement, and condition. For a safety-related application, also obtain the applicable manual and ensure the replacement is approved for the existing safety design.