DUELCO NST-2004 Emergency Stop Safety Relay

  • Manufacturer: Duelco A/S
  • Model: NST-2004
  • Product type: Emergency-stop safety relay
  • Primary function: Monitoring emergency-stop devices and other compatible safety inputs
  • Supported applications: Emergency-stop buttons, safety doors, light curtains, and magnetic safety switches
  • Output configuration: Safety relay contacts; transistor monitoring output on applicable variants
  • Mounting: DIN rail
  • Safety standard reference: EN ISO 13849-1; manufacturer documentation lists Performance Level e / Category 4
  • Supply variants: 24 VDC, 8–36 VDC, and 230 VAC variants are listed
  • Procurement caution: NST-2004F and NST-2004D are distinct variants. Confirm the complete suffix and article number before ordering.
Categories: , , , , SKU: NST-2004 Brand:

Description

Key Technical Specifications

Parameter Specification
Manufacturer Duelco A/S
Model NST-2004
Device type Emergency-stop safety relay
Safety input applications E-stop switches, safety doors, light curtains, magnetic switches
Supply voltage variants 24 VDC; 8–36 VDC; 230 VAC, depending on version
Safety outputs 3 normally open (NO) safety contacts and 1 normally closed (NC) contact, depending on variant
PLC monitoring Transistor monitoring output on applicable versions
AC-15 switching rating 230 V / 5 A
DC-13 switching rating 24 V / 5 A
Maximum switching capacity 1,380 VA for resistive loads, as specified in the datasheet
Emergency-stop cutout time Less than 30 ms for relay K1
Reactivation time Approximately 0.5 s after emergency-stop release
Mechanical lifetime More than 10 million operations
Mounting DIN rail, snap-on mounting
Dimensions (W × H × D) 22.5 × 114.5 × 99 mm
Weight Approximately 200 g for DC versions; 250 g for AC versions
Operating temperature −25°C to +60°C
Storage temperature −30°C to +70°C
Enclosure protection IP20 terminals; IP40 housing
Safety standard reference EN ISO 13849-1; manufacturer documentation lists PL e / Category 4

Specifications are based on Duelco’s NST-2004 datasheet. Ratings and output arrangements must be checked against the exact version being installed.

 

Product Introduction

The DUELCO NST-2004 provides safety-relay functionality for machinery that requires monitored emergency-stop circuits or protective-device interlocking. It can be used with compatible safety switches, light curtains, and guard-door contacts. Its relay outputs are intended for integration into a properly designed safety circuit, while the monitoring output on applicable variants can provide status information to a PLC. The correct version must be selected according to supply voltage, input configuration, reset requirements, and the machine’s validated safety architecture.

NST-2004

NST-2004

NST-2004

NST-2004

Installation & Configuration Guide

Verify the exact variant

Duelco lists several NST-2004 versions:

Variant Article number Supply
NST-2004F 42010204 24 VDC
NST-2004D 42011204 24 VDC
NST-2004F 42010205 8–36 VDC
NST-2004F 42012301 230 VAC

Confirm the installed relay’s nameplate and article number. Do not select a replacement based on the NST-2004 family name alone.

Isolate the machine

  • Place the machine in a safe state and apply the site’s lockout/tagout procedure.
  • Isolate control power and any external energy sources that could cause hazardous movement.
  • Ensure that the safety circuit cannot be inadvertently re-energized during maintenance.

Check the safety circuit

  • Verify the wiring diagram for the E-stop switches, guard interlocks, or light curtains.
  • Confirm the required two-channel monitoring arrangement and reset method.
  • Check whether the application requires short-circuit monitoring or external contactor feedback.
  • Verify the output contact ratings against the connected load and applicable utilization category.

Mount and wire the relay

  • Install the relay on the specified DIN rail.
  • Use the exact terminal assignments in the manufacturer’s wiring diagram.
  • Keep safety outputs separate from PLC status signals where the circuit design requires it.
  • Do not rely on a PLC monitoring signal as a substitute for the relay’s safety outputs.

Validate safety operation

  • Perform commissioning and validation according to the machine’s risk assessment and approved safety design.
  • Test emergency-stop activation, protective-device interruption, reset behavior, and external contactor monitoring where applicable.
  • Verify that the machine cannot restart unexpectedly after a safety demand.
  • Record the test results and return the equipment to service only after the required safety checks pass.

Safety warning: The NST-2004 is a safety-related component. Installation, replacement, and validation must be performed by qualified personnel. Follow the official manual and the machine’s validated safety design; do not bypass safety contacts or defeat protective devices during troubleshooting.

 

Frequently Asked Questions

Q1: What is the DUELCO NST-2004 used for?

It is an emergency-stop safety relay used to monitor compatible safety devices, including E-stop switches, light curtains, safety doors, and magnetic switches.

Q2: What supply voltage does the NST-2004 require?

The product family includes 24 VDC, 8–36 VDC, and 230 VAC variants. The correct voltage depends on the complete model suffix and article number.

Q3: Does the NST-2004 have a PLC monitoring output?

The manufacturer describes a transistor output for PLC monitoring on applicable versions. This status output should not replace the safety relay’s designated safety contacts.

Q4: What is the emergency-stop response time?

The datasheet specifies a cutout time of less than 30 ms for relay K1. Confirm the exact variant and conditions in the applicable technical documentation.

Q5: Is the NST-2004 suitable for safety-critical applications?

The manufacturer’s documentation references EN ISO 13849-1 and Performance Level e / Category 4. The achieved safety performance depends on the complete safety system, wiring, component selection, validation, and application design—not the relay alone.

Q6: Can NST-2004F replace NST-2004D?

Do not assume interchangeability. Verify the supply, contact arrangement, reset behavior, monitoring output, and terminal configuration against the manufacturer documentation for both variants.

Q7: What should be checked before purchasing a replacement?

Confirm the full model suffix, article number, supply voltage, terminal diagram, output arrangement, and condition. For a safety-related application, also obtain the applicable manual and ensure the replacement is approved for the existing safety design.