Sale!

Emerson Epro PR6423/003-030+CON021 Eddy Current Sensor Assembly

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6423 Series
System Assembly Part Number PR6423/003-030 + CON021
Probe Model PR6423/003-030 (8mm tip, /003 sleeve option, 3.0m cable)
Signal Converter Model CON021
Integral Cable Length 3.0 meters (-030 configuration)
Measuring Range 2.0 mm (80 mils) nominal linear range
Scale Factor / Sensitivity 8.0 V/mm (203.2 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Categories: , , , , SKU: PR6423/003-030+CON021 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Emerson Epro PR6423/003-030+CON021 is a non-contact eddy current displacement measurement system engineered for critical rotating machinery protection and condition monitoring. This integrated assembly combines the PR6423/003-030 8mm proximity probe—featuring a 3.0-meter integral high-frequency coaxial cable—with the matched CON021 signal converter to deliver precise monitoring of radial shaft vibration, axial position, and shaft eccentricity.

Operating on the eddy current principle, the system measures static and dynamic distance changes between the 8mm ceramic/PEEK probe tip and a conductive metallic target surface without physical wear. Capable of operating in severe thermal environments up to +200 °C at the probe head, the assembly provides high signal linearity across a 2.0 mm linear working range, an 8.0 V/mm nominal sensitivity, and a wide frequency response from 0 to 20,000 Hz for gas turbines, steam turbines, compressors, and heavy pumps.

 

Key Technical Specifications

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6423 Series
System Assembly Part Number PR6423/003-030 + CON021
Probe Model PR6423/003-030 (8mm tip, /003 sleeve option, 3.0m cable)
Signal Converter Model CON021
Integral Cable Length 3.0 meters (-030 configuration)
Measuring Range 2.0 mm (80 mils) nominal linear range
Scale Factor / Sensitivity 8.0 V/mm (203.2 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Nominal -24 V DC)
Output Signal Range -4 V DC to -20 V DC proportional to gap distance
Probe Tip Operating Temperature -35 °C to +200 °C (-31 °F to +392 °F)
Converter Operating Temperature -30 °C to +100 °C (-22 °F to +212 °F)
Enclosure Protection Class Probe: IP66 / IP68; Converter (CON021): IP20

 

Detailed Product Overview

The Emerson Epro PR6423/003-030+CON021 system provides machinery protection and diagnostic systems with real-time, non-contact measurements of rotor dynamics in high-speed turbomachinery. Mounted through bearing pedestals or machine casings, the 8mm probe tracks minute shifts in shaft position caused by imbalance, thermal expansion, shaft misalignment, journal bearing wear, or oil whip.

The assembly relies on a matched circuit design: the high-frequency excitation signal generated by the CON021 converter travels through the 3.0-meter coaxial cable to energize the coil inside the probe tip. Changes in the gap distance modulate the electromagnetic field, which the CON021 translates into a proportional DC voltage output. The probe features hermetic sealing (IP66/IP68) and a threaded steel body to withstand hot oil, steam, and high housing pressures.

PR6423/003-030 + CON021

PR6423/003-030 + CON021

Engineering Selection Highlights

  • Matched Probe-Converter Pair: Factory-calibrated loop ensures precise 8.0 V/mm scale factor accuracy without requiring manual field tuning.
  • 3.0-Meter Integral Cable Length: Provides sufficient cable reach to route through machine casings directly to external junction boxes without intermediate extension connectors.
  • High Thermal Endurance: Probe head is rated for continuous exposure up to +200 °C near turbine bearings and hot machine components.
  • Non-Contact Wear-Free Operation: Measures static shaft position (0 Hz) and dynamic vibration up to 20,000 Hz without mechanical contact or physical wear.
  • Rugged Sealed Housing: Hermetically sealed IP68 probe tip prevents oil and steam ingress under continuous operating pressure.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Monitoring Racks & DCS Epro MMS6000 protection system, PLC analog inputs, or vibration monitors Channel input must support negative supply voltage (-24 V DC nominal) and negative voltage signal processing.
Target Material Standard Ferromagnetic steel targets (standard calibration on 42CrMo4 / AISI 4140) Non-ferrous target metals alter magnetic permeability and require specific recalibration.
Power Supply Requirement Regulated -24 V DC power supply Clean, low-ripple power input is required to prevent electrical supply noise on the output signal.
Cabinet Installation IP65/IP66 local junction box for CON021 mounting CON021 converter is rated IP20 and must be housed in a protective enclosure.

 

Dimensions, Mounting & Connection Notes

  • Probe Tip Diameter: 8 mm outer diameter.
  • Integral Cable Length: 3.0 meters (approx. 9.8 ft) high-frequency coaxial cable.
  • CON021 Mounting: Compact aluminum housing secured via four M5 mounting screws inside a local junction box.
  • Terminal Wiring: CON021 features screw terminal block connections supporting wire cross-sections up to 1.5 mm^2.
  • Mechanical Gap Setup: Set static mechanical gap using a feeler gauge or by monitoring the CON021 DC output voltage (typically set to mid-scale, approx. -10 V DC or 1.0 mm gap).

 

FAQ

What is the Emerson Epro PR6423/003-030+CON021?

It is a complete non-contact eddy current proximity transducer assembly comprising an 8mm probe with a 3.0-meter integral cable (PR6423/003-030) and a signal converter (CON021).

What do the part number designations (/003-030) signify?

The “/003” suffix indicates specific mechanical thread and sleeve construction options, while “-030” specifies a 3.0-meter integral coaxial cable length.

What power supply is required for the CON021 converter?

The CON021 converter requires a negative DC supply voltage between -23 V DC and -32 V DC (nominally -24 V DC).

Can the CON021 converter be mounted directly on the machine?

No. The CON021 converter carries an IP20 protection rating and must be mounted inside a protective junction box or control cabinet near the machine.

What is the linear measuring range of this system?

The system features a nominal linear measuring range of 2.0 mm (80 mils) with an 8.0 V/mm output scale factor.

 

Verification & Troubleshooting Notes

  • Initial DC Gap Voltage Check: Following mechanical installation, verify that the static DC output voltage at the CON021 terminal reads near the center of the linear working curve (typically -10 V DC for a 1.0 mm gap).
  • Power Supply Integrity: Confirm that the power supply terminals receive a stable negative voltage (-24 V DC nominal) free from high-frequency switching noise.
  • Coaxial Connector Locking: Ensure the miniature coaxial Lemo connector between the probe cable and the CON021 converter is fully engaged and free of oil or moisture contamination.
  • Target Surface Inspection: Inspect the shaft target area for residual magnetism, scratches, or keyways that could induce electrical runout errors into the vibration signal.