Description
Core Product Summary (Brand / Model / Key Attributes)
The Emerson Epro PR6423/010-000-CN+CON021 is a non-contact eddy current displacement measurement system engineered for critical rotating machinery protection and condition monitoring. This integrated assembly pairs the PR6423/010-000-CN 8mm proximity probe—featuring armored cable protection and specialized mechanical sleeve construction—with the matched CON021 signal converter to deliver continuous monitoring of radial shaft vibration, axial position, and shaft eccentricity.
Operating on the eddy current principle, the system measures static and dynamic distance variations between the 8mm ceramic/PEEK probe tip and a conductive metallic target surface without physical contact or mechanical wear. Capable of withstanding harsh thermal environments up to +200 °C at the probe head, the assembly provides high signal linearity across a 2.0 mm linear working range, an 8.0 V/mm nominal sensitivity, and a wide frequency response from 0 to 20,000 Hz for gas turbines, steam turbines, high-pressure compressors, and heavy industrial pumps.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer & Series | Emerson / Epro, PR6423 Series |
| System Assembly Part Number | PR6423/010-000-CN + CON021 |
| Probe Model | PR6423/010-000-CN (8mm tip, /010 sleeve/armoured cable option) |
| Signal Converter Model | CON021 |
| Measuring Range | 2.0 mm (80 mils) nominal linear range |
| Scale Factor / Sensitivity | 8.0 V/mm (203.2 mV/mil) ± 5% |
| Frequency Response (-3 dB) | 0 Hz to 20,000 Hz |
| Supply Voltage Range | -23 V DC to -32 V DC (Nominal -24 V DC) |
| Output Signal Range | -4 V DC to -20 V DC proportional to gap distance |
| Probe Tip Operating Temperature | -35 °C to +200 °C (-31 °F to +392 °F) |
| Converter Operating Temperature | -30 °C to +100 °C (-22 °F to +212 °F) |
| Enclosure Protection Class | Probe: IP66 / IP68; Converter (CON021): IP20 |
Detailed Product Overview
The Emerson Epro PR6423/010-000-CN+CON021 system supplies machinery protection racks and diagnostic software with precise real-time data on rotor dynamics in high-speed industrial machinery. Installed through machine casings or bearing housings, the 8mm probe tracks minute shifts in shaft position caused by unbalance, shaft misalignment, thermal growth, journal bearing wear, or oil whip.
The assembly utilizes a matched circuit architecture: the CON021 signal converter delivers high-frequency excitation to the coil inside the probe head via the high-frequency coaxial cable. Dynamic changes in the mechanical air gap modulate the electromagnetic field, which the CON021 translates into a proportional negative DC voltage output. The probe features hermetic sealing (IP66/IP68), stainless steel armoured cable jacketing, and a threaded steel body to resist hot lubricating oil, steam, and elevated housing pressures.
Engineering Selection Highlights
- Matched Probe & Converter Loop: Factory-calibrated pairing guarantees accurate 8.0 V/mm scale factor performance without requiring complex manual field tuning.
- Armoured Cable Protection: The flexible stainless steel armour tube protects internal coaxial wiring against mechanical crushing, pinching, and abrasion in harsh machine environments.
- High Temperature Resilience: The probe tip and body are rated for continuous operation up to +200 °C near hot bearings and turbine casings.
- Non-Contact Wear-Free Operation: Measures static shaft position (0 Hz) and high-frequency dynamic vibration up to 20,000 Hz without physical contact.
- Hermetic & Pressure-Tight Seal: Rated IP68 to prevent oil and steam ingress through the probe head and cable entry under continuous operating pressure.

PR6423/010-000-CN+CON021

PR6423/010-000-CN+CON021
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Monitoring Racks & DCS | Epro MMS6000 protection system, PLC analog inputs, or vibration monitors | Channel input must support negative power excitation (-24 V DC nominal) and negative voltage signal processing. |
| Target Material Standard | Ferromagnetic steel targets (standard calibration on 42CrMo4 / AISI 4140) | Non-ferrous target metals alter magnetic permeability and require specific system recalibration. |
| Power Supply Requirement | Regulated -24 V DC power supply | Clean, low-ripple power input is required to prevent electrical supply noise on the output signal. |
| Cabinet Installation | IP65/IP66 local junction box for CON021 mounting | CON021 converter is rated IP20 and must be housed in a protective enclosure. |
Dimensions, Mounting & Connection Notes
- Probe Tip Diameter: 8 mm outer diameter.
- Cable Protection: Flexible stainless steel armour tubing over high-frequency coaxial cable.
- CON021 Mounting: Compact aluminum housing secured via four M5 mounting screws inside a local junction box or cabinet rail.
- Terminal Wiring: CON021 features screw terminal block connections supporting wire cross-sections up to 1.5 mm^2.
- Mechanical Gap Setup: Set static mechanical gap using a feeler gauge or by monitoring the CON021 DC output voltage (typically set to mid-scale, approx. -10 V DC or 1.0 mm gap).
FAQ
What is the Emerson Epro PR6423/010-000-CN+CON021?
It is a non-contact eddy current proximity transducer system consisting of an 8mm probe with armoured cable (PR6423/010-000-CN) and a signal converter (CON021).
What do the part number designations (/010-000-CN) signify?
The “/010” designation indicates specific mechanical thread/sleeve construction and integral cable length, while “-CN” specifies standardized connector and armor options.
What power supply is required for the CON021 converter?
The CON021 converter requires a negative DC supply voltage ranging between -23 V DC and -32 V DC (nominally -24 V DC).
Can the CON021 converter be mounted directly on the machine?
No. The CON021 converter carries an IP20 protection rating and must be mounted inside a protective junction box or control cabinet near the machine.
What is the linear measuring range of this system?
The system features a nominal linear measuring range of 2.0 mm (80 mils) with an 8.0 V/mm output scale factor.
Verification & Troubleshooting Notes
- Initial DC Gap Voltage Check: Following mechanical installation, verify that the static DC output voltage at the CON021 terminal reads near the center of the linear working curve (typically -10 V DC for a 1.0 mm gap).
- Power Supply Integrity: Confirm that the power supply terminals receive a stable negative voltage (-24 V DC nominal) free from high-frequency switching noise.
- Coaxial Connector Locking: Ensure the miniature coaxial connector between the probe cable and the CON021 converter is fully engaged and free of oil or moisture contamination.
- Target Surface Inspection: Inspect the shaft target area for residual magnetism, mechanical scratches, or keyways that could induce electrical runout errors into the vibration signal.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626