Sale!

Emerson Epro PR6423/10R-030-CN+CON021 Eddy Current Proximity Sensor Assembly

Parameter Specification
Manufacturer & Series Emerson Epro, PR6423 Proximity Measurement Series
System Assembly Part Number PR6423/10R-030-CN + CON021
Probe Model PR6423/10R-030-CN (8mm probe with 3.0 m cable)
Signal Converter Model CON021
Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils) typical
Incremental Scale Factor (ISF) 8 V/mm (203.2 mV/mil) ± 5% (0 to 45°C)
Frequency Response (-3 dB) 0 to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Output range: -4 V to -20 V)
Minimum Shaft Diameter 25 mm (0.79 in.) on ferromagnetic steel (42CrMo4)
Probe Temperature Range -35 °C to +200 °C (-31 °F to +392 °F)
Converter Temperature Range -30 °C to +100 °C (-22 °F to +212 °F)
Enclosure Protection Class Probe: IP66 / IP68; Converter (CON021): IP20
Categories: , , , , SKU: PR6423/10R-030-CN+CON021 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Emerson Epro PR6423/10R-030-CN+CON021 is an industrial eddy current displacement and vibration measurement system designed for critical turbomachinery applications, including steam turbines, gas turbines, large compressors, and industrial pumps. This integrated hardware assembly combines the PR6423/10R-030-CN 8mm proximity probe with the CON021 signal converter to deliver precise, non-contact monitoring of radial shaft vibration, axial displacement, and shaft eccentricity.

The system operates on the eddy current principle, measuring changes in high-frequency electromagnetic fields generated at the probe tip relative to a conductive target surface. Featuring a 3.0-meter high-frequency coaxial cable, threaded probe body construction, and a rugged CON021 signal conditioning module, the assembly provides high signal linearity, wide frequency response from 0 to 20,000 Hz, and reliable performance across harsh operating environments.

 

Key Technical Specifications

Parameter Specification
Manufacturer & Series Emerson Epro, PR6423 Proximity Measurement Series
System Assembly Part Number PR6423/10R-030-CN + CON021
Probe Model PR6423/10R-030-CN (8mm probe with 3.0 m cable)
Signal Converter Model CON021
Measurement Range 2 mm (80 mils)
Initial Air Gap 0.5 mm (20 mils) typical
Incremental Scale Factor (ISF) 8 V/mm (203.2 mV/mil) ± 5% (0 to 45°C)
Frequency Response (-3 dB) 0 to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Output range: -4 V to -20 V)
Minimum Shaft Diameter 25 mm (0.79 in.) on ferromagnetic steel (42CrMo4)
Probe Temperature Range -35 °C to +200 °C (-31 °F to +392 °F)
Converter Temperature Range -30 °C to +100 °C (-22 °F to +212 °F)
Enclosure Protection Class Probe: IP66 / IP68; Converter (CON021): IP20

 

Detailed Product Overview

The Emerson Epro PR6423/10R-030-CN+CON021 assembly provides condition monitoring systems with continuous, real-time diagnostic data regarding mechanical health and rotor dynamics in rotating machinery. By establishing a precise non-contact measurement setup, the system tracks dynamic shifts in shaft position caused by unbalance, misalignment, bearing wear, or thermal expansion.

The probe tip utilizes rugged PEEK or ceramic materials encased in a threaded metal housing, allowing direct installation into machinery casings via standard mounting threads. The integrated high-frequency coaxial cable connects securely to the CON021 signal converter using a self-locking Lemo plug, preventing signal interruption from severe mechanical vibration. The CON021 converter processes the high-frequency oscillator signals, converting distance changes into a proportional voltage output that interfaces directly with vibration monitoring racks, protection systems, and Distributed Control Systems (DCS).

 

Engineering Selection Highlights

  • Non-Contact Measurement Principle: Eliminates mechanical wear and tear by measuring relative shaft motion without physical contact.
  • Wide Frequency Response: Operates from 0 Hz (static position) up to 20,000 Hz (high-frequency dynamic vibration), capturing fast transient events.
  • Matched Component Calibration: Probe length, cable capacitance, and the CON021 converter are factory-matched to ensure signal linearity and precise scale factor accuracy (8 V/mm).
  • Robust Environmental Resilience: Built to withstand elevated operational temperatures up to 200 °C at the probe tip and resistant to industrial lubricants, steam, and moisture.
  • Standardized Signal Output: Delivers a proportional DC voltage output compatible with standard industrial machinery protection and monitoring instrumentation.
PR6423/10R-030-CN+CON021

PR6423/10R-030-CN+CON021

PR6423/10R-030-CN+CON021

PR6423/10R-030-CN+CON021

Dimensions, Mounting & Connection Notes

  • Probe Thread Size: Standard metric fine threads (e.g., M10x1) matching PR6423 mechanical configurations.
  • Cable Length: 3.0 meters integral high-frequency coaxial cable (-030 designation).
  • CON021 Dimensions: Compact housing block secured via four M5x20 mounting screws.
  • Converter Terminals: Screw terminal block supporting wire cross-sections up to 1.5 mm^2 with wire-end sleeves for power and signal lines.
  • Shielding & Grounding: The coaxial cable shield must be grounded continuously through the CON021 housing to prevent electromagnetic interference (EMI) pickup from nearby variable frequency drives or high-voltage lines.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Signal Monitoring Systems Epro MMS6000 protection racks, PLC analog input cards, or vibration monitors Input channel must support negative supply excitation (-24 V DC nominal) and voltage scaling.
Target Material Ferromagnetic steel targets (e.g., 42CrMo4) Non-ferromagnetic materials change sensitivity and require specific calibration curves.
Power Supply Regulated -24 V DC instrument power supply Clean, low-noise power supply is required to prevent voltage ripple interference on vibration outputs.
Extension and Interconnect Self-locking Lemo connector interface between probe cable and CON021 Ensure mechanical locking mechanism is fully engaged to maintain shield continuity.
Enclosure / Junction Box Local local junction box (IP65/IP66) for CON021 mounting CON021 converter features IP20 protection and must be installed inside a protected cabinet or junction box.

 

FAQ

What is the Emerson Epro PR6423/10R-030-CN+CON021?

It is a non-contact eddy current proximity sensor assembly consisting of an 8mm probe (PR6423/10R-030-CN) and a signal converter (CON021) used to measure shaft vibration and displacement.

What do the part number suffixes (-030-CN) signify?

The “-030” indicates a 3.0-meter integral cable length, and “-CN” designates specific mechanical and electrical connector configurations standard to Epro sensor lines.

What is the primary application for this sensor system?

It is deployed on critical industrial turbomachinery—such as steam and gas turbines, compressors, and large generators—to measure radial vibration, axial thrust position, and shaft eccentricity.

What power supply does the CON021 converter require?

It requires a negative DC supply voltage ranging between -23 V DC and -32 V DC (nominally -24 V DC).

Can the probe withstand high temperatures?

Yes, the PR6423 probe tip and body are rated for continuous operation in environments up to 200 °C (-31 °F to +392 °F).

Is recalibration necessary if the extension cable is changed?

Yes. Eddy current systems are tuned as a complete loop (probe, cable length, and driver). Changing cable length alters total capacitance and invalidates the factory scale factor.

 

Verification & Troubleshooting Notes

  • Initial Air Gap Verification: Confirm that the static mechanical air gap between the probe tip and the rotating shaft surface is set correctly to 0.5 mm (20 mils) or the center of the linear working range using a digital multimeter measuring converter output voltage.
  • Supply Voltage Check: Verify that the incoming power rail at the CON021 terminal measures a stable negative voltage (approximately -24 V DC) with minimal AC ripple.
  • Signal Noise Diagnostics: If erratic vibration spikes occur, inspect the coaxial cable path to ensure it is segregated from high-current motor cables, power feeds, and VFD wiring to eliminate electromagnetic noise coupling.
  • Target Surface Inspection: Ensure the target track on the rotating shaft is clean, demagnetized, and free of mechanical runout, scratches, or burrs that could distort the eddy current field.