Sale!

Emerson Epro PR6424/010-130+CON011 Extended Range Eddy Current Sensor System

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6424 Series
System Assembly Part Number PR6424/010-130 + CON011
Probe Model PR6424/010-130 (16mm tip diameter, /010 sleeve configuration)
Signal Converter Model CON011
Integral Cable Length 13.0 meters (-130 configuration)
Measuring Range 4.0 mm (160 mils) nominal linear range
Scale Factor / Sensitivity 4.0 V/mm (101.6 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Categories: , , , , SKU: PR6424/010-130+CON011 Brand:

Description

Core Product Summary (Brand / Model / Key Attributes)

The Emerson Epro PR6424/010-130+CON011 is an industrial, non-contact eddy current displacement measurement assembly engineered for high-reliability turbomachinery protection and condition monitoring. This integrated system pairs the PR6424/010-130 16mm proximity probe—featuring a 13.0-meter integral high-frequency cable—with the matched CON011 signal converter to deliver continuous monitoring of axial shaft displacement, rod drop, thermal expansion, and relative shaft position.

Operating on the non-contact eddy current physical principle, the assembly measures static and dynamic distance variations between the 16mm ceramic/PEEK probe head and a conductive metallic target surface without physical wear. Utilizing the larger 16mm probe tip geometry, the PR6424 series provides an extended measuring range up to 4.0 mm (160 mils) and an output scale factor of 4.0 V/mm. Coupled with the CON011 signal conditioner, it ensures stable signal processing in high-temperature environments up to +200 °C for large steam turbines, gas turbines, heavy turbo-compressors, and industrial pumps.

 

Key Technical Specifications

Parameter Specification
Manufacturer & Series Emerson / Epro, PR6424 Series
System Assembly Part Number PR6424/010-130 + CON011
Probe Model PR6424/010-130 (16mm tip diameter, /010 sleeve configuration)
Signal Converter Model CON011
Integral Cable Length 13.0 meters (-130 configuration)
Measuring Range 4.0 mm (160 mils) nominal linear range
Scale Factor / Sensitivity 4.0 V/mm (101.6 mV/mil) ± 5%
Frequency Response (-3 dB) 0 Hz to 20,000 Hz
Supply Voltage Range -23 V DC to -32 V DC (Nominal -24 V DC)
Output Signal Range Proportional negative DC voltage output
Probe Tip Operating Temperature -35 °C to +200 °C (-31 °F to +392 °F)
Converter Operating Temperature -30 °C to +100 °C (-22 °F to +212 °F)
Enclosure Protection Class Probe: IP66 / IP68; Converter (CON011): IP20

 

Detailed Product Overview

The Emerson Epro PR6424/010-130+CON011 transducer assembly provides continuous machinery protection systems, vibration monitors, and Distributed Control Systems (DCS) with real-time positional data on critical machinery rotors. The larger 16mm probe head is specifically selected for applications requiring an extended measurement range—such as axial thrust position monitoring, rod drop measurement on reciprocating compressors, and differential thermal expansion tracking on large steam turbine rotors.

The assembly relies on a matched circuit architecture: the CON011 signal converter supplies high-frequency excitation to the coil embedded inside the 16mm probe head via the 13.0-meter cable. Dynamic changes in the mechanical air gap modulate the electromagnetic field, which the CON011 translates into a proportional negative DC voltage output. The probe features hermetic sealing (IP66/IP68) and a heavy-duty threaded steel body to withstand hot lubricating oil, steam, and high housing pressures.

 

Engineering Selection Highlights

  • Extended 13.0-Meter Integral Cable Reach: Extended cable length allows direct routing from internal bearing housings to remotely located terminal boxes without requiring intermediate extension cables or connectors.
  • Extended 4.0 mm Linear Range: 16mm probe head geometry doubles the measuring range compared to standard 8mm probes, making it ideal for axial displacement and thermal expansion tracking.
  • CON011 Signal Conditioning: Dedicated signal driver processes high-frequency signals into clean, linear negative DC voltage proportional to distance.
  • High Temperature Resilience: Rated for continuous operation up to +200 °C near hot bearings and turbine casings.
  • Non-Contact Wear-Free Operation: Tracks static shaft position (0 Hz) and dynamic position changes up to 20,000 Hz without physical contact.
PR6424/010-130+CON011

PR6424/010-130+CON011

PR6424/010-130+CON011

PR6424/010-130+CON011

Dimensions, Mounting & Connection Notes

  • Probe Tip Diameter: 16 mm outer diameter.
  • Integral Cable Length: 13.0 meters (approx. 42.6 ft) high-frequency cable.
  • CON011 Mounting: Compact aluminum housing secured via mounting screws inside a local junction box or cabinet rail.
  • Terminal Wiring: CON011 features screw terminal block connections supporting wire cross-sections up to 1.5 mm^2.
  • Mechanical Gap Setup: Set static mechanical gap using a feeler gauge or by monitoring the CON011 DC output voltage (typically set to mid-scale, approx. -10 V DC or 2.0 mm gap).

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Monitoring Racks & DCS Epro MMS6000 protection system, PLC analog inputs, or vibration monitors Channel input must support negative supply excitation (-24 V DC nominal) and negative voltage signal processing.
Target Material Standard Ferromagnetic steel targets (standard calibration on 42CrMo4 / AISI 4140) Target area diameter must be at least 30 mm to avoid edge-effect measurement errors.
Power Supply Requirement Regulated -24 V DC power supply Clean, low-ripple power input is required to prevent electrical supply noise on the output signal.
Cabinet Installation IP65/IP66 local junction box for CON011 mounting CON011 converter is rated IP20 and must be housed in a protective enclosure.

 

FAQ

What is the Emerson Epro PR6424/010-130+CON011?

It is a non-contact eddy current proximity transducer assembly consisting of a 16mm probe with a 13.0-meter integral cable (PR6424/010-130) and a CON011 signal converter.

How does the CON011 driver function within this assembly?

The CON011 acts as the signal conditioner, generating high-frequency excitation for the 16mm probe coil and converting target distance shifts into a proportional negative DC voltage output.

How does the PR6424 series differ from the PR6423 series?

The PR6424 series uses a larger 16mm tip head providing a 4.0 mm linear range and 4.0 V/mm scale factor, whereas the PR6423 series uses an 8mm tip with a 2.0 mm range and 8.0 V/mm scale factor.

What power supply is required for the CON011 converter?

The CON011 converter requires a negative DC supply voltage ranging between -23 V DC and -32 V DC (nominally -24 V DC).

What is the primary application for a 16mm probe system?

It is primarily used for axial thrust position monitoring, rod drop detection on compressors, and measuring large thermal expansion displacements on heavy turbomachinery.

 

Verification & Troubleshooting Notes

  • Initial DC Gap Voltage Check: Following mechanical installation, verify that the static DC output voltage at the CON011 terminal reads near the center of the linear working curve (typically -10 V DC for a 2.0 mm gap).
  • Target Area Clearance: Ensure the metal target surface diameter is at least 30 mm to prevent side clearance errors or uncalibrated magnetic field spreading.
  • Power Supply Integrity: Confirm that the power supply terminals receive a stable negative voltage (-24 V DC nominal) free from high-frequency switching noise.
  • Coaxial Connector Locking: Ensure the miniature coaxial connector between the probe cable and the CON011 converter is fully engaged and free of oil or moisture contamination.