Sale!

Emerson KJ3242X1-BK1 Dual RS232/RS485 Serial Terminal Block

  • Model: KJ3242X1-BK1 (VE4050S2B2)
  • Brand: Emerson DeltaV
  • Series: DeltaV M-Series / S-Series
  • Core Function: Routes serial communication lines (RS232/RS485/RS422) to DeltaV serial cards.
  • Product Type: 2-Port Serial Interface Terminal Block
  • Key Specs: 2 Serial Ports | RS232 / RS422 / RS485 Field Selectable | 1000 VAC Isolation
  • Condition: New Original / New Surplus
  • Inventory Status: Active critical spare; maintain 1–2 units on-site as insurance against field surges and serial channel failures.
Categories: , , , , SKU: KJ3242X1-BK1 Brand:

Description

Key Technical Specifications

Parameter Specification / Value
Manufacturer Emerson Automation Solutions
Part Number KJ3242X1-BK1
Assembly Code VE4050S2B2
System Compatibility Emerson DeltaV DCS
Communication Ports 2 Independent Channels
Physical Interface Options RS232, RS422, RS485 (2-wire / 4-wire)
Baud Rate Range 300 bps to 115.2 kbps
Galvanic Isolation 1000 VAC field-to-bus, channel-to-channel isolation
Termination Connection Screw Clamp Terminals with Shield/Ground Clamps
Carrier Power Consumption 5 VDC at 150 mA (drawn via backplane)
Operating Temperature −40°C to +70°C (−40°F to +158°F)
Mounting Style DeltaV 2-wide / 8-wide I/O Carrier Rail

 

Product Introduction & Supply Chain Strategy

The Emerson KJ3242X1-BK1 (VE4050S2B1 revision upgrade VE4050S2B2) is a 2-port serial interface terminal block engineered to route RS232, RS422, and RS485 field communications into Emerson DeltaV DCS serial cards. It provides physical signal termination, surge isolation, and ground shielding for critical data links connecting variable frequency drives, power monitors, weigh scales, and third-party PLCs. Designed for continuous industrial process control, this assembly ensures high signal noise immunity and robust physical connections across refinery, chemical processing, and power plant control environments.

Procuring this assembly as New Surplus offers immediate delivery and full OEM-grade reliability without paying list price or enduring lengthy factory lead times. Unlike second-hand components, authentic New Surplus inventory guarantees immaculate backplane connector pins, uncompromised optical isolation components, and zero thermal degradation. Holding 1–2 unused terminal blocks in local plant inventory reduces Total Cost of Ownership (TCO) by eliminating emergency shipping fees and preventing extended unit outages during field line faults or lightning surges.

KJ3242X1-BK1

KJ3242X1-BK1

KJ3242X1-BK1

KJ3242X1-BK1

Installation & Configuration Guide

1.Pre-Installation (Prep & Safety):Prerequisite.

Execute Lock-Out/Tag-Out (LOTO) on connected external serial devices and power supplies. Put on a grounded ESD wrist strap before handling the replacement module. Photograph existing wiring connections and tag field conductors (TX, RX, RTS, CTS, Shield) to ensure pinout retention.

2.Removal:Mechanical extraction.

Unscrew terminal block connections or pull serial interface plugs. Unlatch the upper and lower carrier retention tabs on the terminal block. Slide the KJ3242X1-BK1 straight off the DeltaV carrier guide rails to avoid bending or breaking backplane gold pins.

3.Installation (Clone & Seat):Hardware mounting.

Inspect the backplane connector on the new KJ3242X1-BK1 for dust or pin misalignment. Align the housing guide slots with the carrier rails. Push the terminal block firmly into the carrier slot until the retention tabs lock with an audible click. Reconnect field wiring strictly following the original channel schematic.

4.Power-On & Testing:System verification.

Reapply carrier power and verify that the associated DeltaV serial I/O card powers up normally. Check that TX/RX LEDs indicate active polling without protocol error indications. Open DeltaV Diagnostics to verify that both serial channels report normal online status with zero framing errors.

 

Firmware/Software Versions & Upgrade Notes

  • System Compatibility: Supports DeltaV v12.3.1, v13.3.1, v14.3, and v15.3 systems utilizing standard or redundant serial interface modules.
  • Firmware Dependency: The KJ3242X1-BK1 is a passive/active physical interface block and does not contain user-flashable firmware. Revision updates (such as BK1) indicate physical component revisions that remain fully backward compatible with older VE4050S2B1 applications.
  • Serial Protocol Setup: Ensure that baud rate, parity, data bits, stop bits, and protocol selection (Modbus RTU Master/Slave or Generic Serial) configured in DeltaV Explorer match external device parameters precisely.
  • Termination Resistors: When operating long RS485 loops, verify that internal or external 120-ohm termination resistors are switched on at both physical ends of the communication cable to prevent signal reflections.

 

Frequently Asked Questions (FAQ)

Q: Is this Emerson KJ3242X1-BK1 unit brand new or refurbished?

A: This product is a Brand New Surplus unit. It is not used, not pulled from a decommissioned plant, and not refurbished. All modules undergo rigorous quality verification to ensure OEM-level reliability.

Q: What is the main difference between New Surplus and factory-ordered OEM parts?

A: New Surplus inventory consists of genuine OEM parts sourced from excess project inventory, canceled facility builds, or surplus maintenance stock. You receive identical factory quality and performance at a 20% to 30% lower cost, with immediate off-the-shelf dispatch instead of weeks of factory lead time.

Q: Why should we avoid buying refurbished or pulled serial terminal blocks?

A: Refurbished and pulled interface blocks frequently suffer from micro-fractures in screw terminals, worn backplane contacts, or degraded optocoupler isolation caused by past electrical noise or thermal cycling. A failed 350 refurbished block can interrupt communications to a critical PLC or VFD network, costing 40,000 to $100,000 per hour in unscheduled plant downtime.

Q: Can I hot-swap this terminal block while the DeltaV controller is running?

A: Yes, DeltaV I/O carriers support live hot-swapping of terminal blocks. However, to prevent arcing or transient voltage spikes on communication lines, you should temporarily disable active serial polling or disconnect external device field power prior to extraction.

Q: Does swapping this terminal block require software reconfiguration in DeltaV?

A: No, the is an interface assembly. All Modbus mapping, serial port addresses, baud rate definitions, and protocol driver software reside in the DeltaV Controller and Serial I/O Module memory. Replacing the terminal block requires zero programming changes.

Q: What warranty is provided with this New Surplus assembly?

A: We back this unit with a full 1-year operational replacement warranty. Each block undergoes thorough visual, mechanical, and backplane continuity testing before being vacuum-sealed in ESD-safe packaging for shipment.