Description
Core Product Summary
The Emerson SE4006P2 is a DeltaV S-series serial interface that connects the DeltaV distributed control system to serial devices such as Modbus devices and Allen-Bradley Data Highway Plus systems. The two-port interface is supplied with Modbus software drivers preloaded.
The SE4006P2 consists of a serial interface card and a simplex terminal block. Its two independently configurable ports support RS-232, RS-422/485 half-duplex, and RS-422/485 full-duplex communication. The card can be installed as a redundant pair for critical applications requiring higher availability.
Key Technical Specifications
| Item | Specification |
|---|---|
| Manufacturer / model | Emerson SE4006P2 |
| Product type | S-series serial interface card, two ports |
| System family | Emerson DeltaV S-series |
| Configuration | Serial interface card plus simplex terminal block |
| Serial ports | 2, independently configurable |
| Physical interfaces | RS-232, RS-422/485 half-duplex, RS-422/485 full-duplex |
| Serial data rate | 300 baud to 115 KBaud |
| Data sets per card | 32 |
| Data sets per port | 16 |
| Preloaded protocol | Modbus software driver |
| Redundancy | Can be installed as a redundant pair |
| Terminal block | Simplex terminal block |
| Operating temperature | -40 to 70 °C |
| Storage temperature | -40 to 85 °C |
| Relative humidity | 5 to 95%, non-condensing |
| Contaminant rating | ISA-S71.04-1985 Class G3 conformal coating |
| Protection rating | IP20 |
| Shock rating | 10 g half-sine shock for 11 ms |
| Vibration rating | 3 mm peak-to-peak from 5 to 13 Hz; 0.5 g from 13 to 150 Hz |
Detailed Product Overview
The Emerson SE4006P2 provides serial connectivity between a DeltaV S-series controller and field devices, PLCs, analyzers, scales, and other equipment that use supported serial protocols. Each card provides two serial ports, and each port can be configured independently for RS-232, RS-422/485 half-duplex, or RS-422/485 full-duplex operation.
The card supports serial data rates from 300 baud to 115 KBaud. It provides 32 data sets per card, with up to 16 data sets available on each port. These data-set registers can be referenced as analog or discrete I/O in DeltaV control modules, allowing serial device data to participate in control logic and operator displays.
The SE4006P2 is supplied with Modbus drivers preloaded and supports Modbus RTU and ASCII operation. Each port can be configured as a Modbus master or slave. Through Modbus, the interface can read coils, input statuses, holding registers, and discrete input registers, and can write to coils and holding registers. Emerson also documents support for downloading other serial drivers, including Allen-Bradley Data Highway Plus and drivers for Mettler and Sartorius scales.
The interface uses a simplex terminal block for field-side connection. For applications that require continued communication through a controller or card fault, two SE4006P2 interfaces can be installed as a redundant pair. The system detects the redundant terminal block and identifies the two cards as a redundant pair.

SE4006P2

SE4006P2
Dimensions, Mounting & Connection Notes
The SE4006P2 is an S-series I/O card intended for installation in a DeltaV S-series I/O carrier. It is supplied with a simplex terminal block, which provides the field-side connection for the two serial ports.
The card supports three serial physical layers: RS-232, RS-422/485 half-duplex, and RS-422/485 full-duplex. The two ports are independently configurable, so each port can use a different physical layer and communication configuration where supported by the connected devices.
The module is rated IP20 and uses ISA Class G3 conformal coating. It operates from -40 to 70 °C, stores from -40 to 85 °C, and tolerates 5 to 95% non-condensing relative humidity. Its documented mechanical ratings include 10 g half-sine shock for 11 ms and vibration of 3 mm peak-to-peak from 5 to 13 Hz or 0.5 g from 13 to 150 Hz.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Control system | Emerson DeltaV S-series | The SE4006P2 is an S-series serial interface |
| Serial protocols | Modbus and Allen-Bradley Data Highway Plus | Modbus drivers are preloaded; other drivers may be downloaded |
| Serial physical layers | RS-232, RS-422/485 half-duplex, RS-422/485 full-duplex | Each port is independently configurable |
| Serial devices | Modbus devices and other supported serial devices | Includes PLCs, analyzers, scales, and similar serial equipment |
| Terminal block | Simplex terminal block | Included in the SE4006P2 configuration |
| Redundant installation | Two SE4006P2 interfaces as a redundant pair | Intended for critical applications requiring higher availability |
| Data exchange | Up to 32 data sets per card; up to 16 per port | Data-set registers can be used as analog or discrete I/O in control modules |
| Configuration | DeltaV system configuration | Port parameters, protocol settings, and data-set assignments are configured in the DeltaV system |
FAQ
What is the Emerson SE4006P2?
It is an Emerson DeltaV S-series serial interface card with two independently configurable serial ports and a simplex terminal block.
Which serial physical layers does the SE4006P2 support?
It supports RS-232, RS-422/485 half-duplex, and RS-422/485 full-duplex communication.
What protocols does it support?
It is supplied with preloaded Modbus software drivers and supports Modbus RTU and ASCII. It can also connect to devices using Allen-Bradley Data Highway Plus through downloadable drivers.
Can each serial port be configured separately?
Yes. The SE4006P2 has two independently configurable ports.
What serial data rate does it support?
It supports serial data rates from 300 baud to 115 KBaud.
How much data can one SE4006P2 exchange?
One card supports 32 data sets, with up to 16 data sets on each serial port.
Can the SE4006P2 be redundant?
Yes. Two SE4006P2 serial interfaces can be installed as a redundant pair for critical applications requiring higher availability.
What is included with the SE4006P2?
The SE4006P2 consists of a serial interface card and a simplex terminal block.
Documented Performance Data
| Metric | Value / Range | Operating Condition |
|---|---|---|
| Serial data rate | 300 baud to 115 KBaud | Per independently configurable serial port |
| Data sets per card | 32 | SE4006P2 serial interface card |
| Data sets per port | 16 | Each of the two serial ports |
| Modbus operation | Master or slave | Configurable per serial port |
| Redundant operation | Two-card redundant pair | For critical applications requiring higher availability |

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626