Description
Core Product Summary
The Emerson SE4022 is the complete simplex assembly consisting of the KJ3243X1-BK1 PROFIBUS DP interface card and its matching KJ4006X1-BQ1 terminal block. It serves as a native PROFIBUS DP master interface for DeltaV S-series controllers, enabling direct integration of PROFIBUS DP field devices such as motor control centers, variable-speed drives, and remote I/O into the DeltaV control system.
The card draws 12 V DC at 600 mA from the local bus, operates from –40 °C to +70 °C, and is certified for Class I Division 2 / Zone 2 hazardous locations (II 3G Ex ec IIC Gc). It supports a single PROFIBUS DP port with up to 64 devices and standard baud rates from 9.6 kbit/s to 1.5 Mbit/s.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product type | PROFIBUS DP Interface Card (Simplex) |
| Assembly order code | SE4022 |
| Card model | KJ3243X1-BK1 |
| Terminal block | KJ4006X1-BQ1 |
| Number of ports | 1 |
| Maximum devices | 64 |
| Local bus power | 12 V DC at 600 mA |
| Operating temperature | –40 °C to +70 °C |
| Storage temperature | –40 °C to +85 °C |
| Relative humidity | 5 % to 95 % non-condensing |
| Shock | 10 g ½-sine wave for 11 ms |
| Vibration | 1 mm peak-to-peak (2–13.2 Hz); 0.7 g (13.2–150 Hz) |
| Terminal block key position | D3 |
| Hazardous area rating | II 3G Ex ec IIC Gc; Class I Div 2 / Zone 2 |
Engineering Selection Highlights
- Native PROFIBUS DP master interface integrates device signals directly into DeltaV control modules without intermediate serial converters or data mapping.
- Supports up to 64 PROFIBUS DP slaves on a single segment, including intelligent motor control centers and variable-speed drives.
- Standard baud rates from 9.6 kbit/s to 1.5 Mbit/s with corresponding cable-length limits (up to 1200 m at lower speeds).
- Zone 2 / Class I Division 2 certification allows installation in hazardous areas without additional barriers.
- Rotary keying system (key position D3) prevents incorrect card insertion after the terminal block is installed.
- Auto-sensed by the DeltaV controller for rapid configuration and commissioning.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| System platform | Emerson DeltaV S-series | Installs on S-series I/O interface carrier |
| Assembly | SE4022 (card + terminal block) | KJ3243X1-BK1 card with KJ4006X1-BQ1 terminal block |
| Power | Local bus 12 V DC | 600 mA maximum |
| Field network | PROFIBUS DP | Single port; up to 64 devices |
| Redundant option | Separate redundant assembly available | Not mixed long-term with newer KJ3243X1-BK2 cards in a redundant pair |
| Hazardous area | Zone 2 / Class I Div 2 | Follow Zone 2 installation instructions |
Dimensions, Mounting & Connection Notes
The SE4022 assembly mounts on a standard S-series I/O interface carrier. The terminal block (key position D3) is installed first and keyed; the KJ3243X1-BK1 card is then inserted. Field power must be removed before removing or inserting the card. The unit contains no user-serviceable parts and must not be disassembled. PROFIBUS DP network cabling connects to the terminal block according to PROFIBUS DP wiring practices.
Detailed Product Overview
The Emerson SE4022 is the factory-ordered simplex assembly that pairs the KJ3243X1-BK1 PROFIBUS DP interface card with the KJ4006X1-BQ1 terminal block. It provides a native PROFIBUS DP master interface for DeltaV S-series controllers, allowing direct connection of PROFIBUS DP field devices into the control system.
The card operates as a PROFIBUS DP master with a single port supporting up to 64 devices. Transmission speeds range from 9.6 kbit/s to 1.5 Mbit/s, with segment lengths up to 1200 m at the lower baud rates. Device signals are integrated directly into DeltaV control modules, eliminating the need for serial interfaces or external data mapping. High data throughput and diagnostic capabilities support complex devices such as motor control centers and variable-speed drives.
Power is supplied solely from the local bus at 12 V DC and 600 mA. The card is rated for continuous operation from –40 °C to +70 °C and meets ISA G3 airborne contaminant requirements with conformal coating. Hazardous-area certification (II 3G Ex ec IIC Gc, Class I Division 2 / Zone 2) permits installation in classified locations when installed according to the applicable Zone 2 instructions.
Installation follows standard S-series practice: the terminal block is mounted and keyed to position D3, after which the card is inserted and automatically detected by the controller. Field power must be removed before any removal or insertion. The assembly contains no user-serviceable parts.
For applications requiring redundancy, a separate redundant PROFIBUS DP assembly is available. Note that the KJ3243X1-BK1 should not be mixed long-term with the newer KJ3243X1-BK2 card in a redundant pair.
The SE4022 / KJ3243X1-BK1 therefore provides a compact, certified, and fully integrated PROFIBUS DP solution for DeltaV process control systems that require reliable communication with discrete and intelligent field devices.

SE4022 KJ3243X1-BK1

SE4022 KJ3243X1-BK1
Applications & System Role
The SE4022 / KJ3243X1-BK1 functions as a PROFIBUS DP master interface within the DeltaV S-series I/O subsystem. It allows control modules running in the DeltaV controller to exchange cyclic process data and acyclic diagnostic/parameter data with PROFIBUS DP field devices.
Typical applications include integration of motor control centers, variable-frequency drives, intelligent remote I/O stations, and other discrete or multi-signal PROFIBUS DP devices. The native bus interface reduces wiring, eliminates intermediate gateways, and provides direct visibility of device status and diagnostics in the DeltaV operator interface and AMS Device Manager.
FAQ
What is the Emerson SE4022 / KJ3243X1-BK1?
It is the DeltaV S-series simplex PROFIBUS DP interface assembly consisting of the KJ3243X1-BK1 card and KJ4006X1-BQ1 terminal block.
How many devices can it support?
Up to 64 PROFIBUS DP devices on a single segment.
What is the power requirement?
Local bus power of 12 V DC at 600 mA.
Is it suitable for hazardous areas?
Yes. It is certified II 3G Ex ec IIC Gc and Class I Division 2 / Zone 2.
What is the operating temperature range?
–40 °C to +70 °C.
Does it support redundant operation?
A separate redundant assembly is available. The KJ3243X1-BK1 should not be mixed long-term with the newer KJ3243X1-BK2 card in a redundant pair.
What is the terminal block key position?
D3.