Emerson VE3006 DeltaV MD Plus Controller

The Emerson VE3006 is the MD Plus controller of the DeltaV distributed control system, part of the M-series controller hardware generation. It is supplied under hardware part numbers including KJ2003X1-BB1 (12P3439X). Within the DeltaV architecture, the controller executes the control strategies downloaded from the DeltaV engineering system and manages the I/O connected to its local bus.

Category: SKU: VE3006 Brand:

Description

Core Product Summary

The Emerson VE3006 is the MD Plus controller of the DeltaV distributed control system, part of the M-series controller hardware generation. It is supplied under hardware part numbers including KJ2003X1-BB1 (12P3439X). Within the DeltaV architecture, the controller executes the control strategies downloaded from the DeltaV engineering system and manages the I/O connected to its local bus.

Emerson positions the MD Plus controller as providing the full features and functions of the M5-class controller, with additional memory aimed at large batch and other memory-intensive applications. The controller draws up to 1.4 A on the 5 VDC LocalBus and operates in ambient temperatures of 0 to 60 °C. For installations where controller availability is critical, the MD Plus supports redundant controller operation, and control strategies and system configurations created on earlier DeltaV systems can be carried over to it.

 

Key Technical Specifications

Parameter Value / Scope
Product type Controller module (DeltaV MD Plus)
Manufacturer Emerson (DeltaV system family)
Controller class M-series, MD Plus
Hardware part numbers KJ2003X1-BB1; 12P3439X
LocalBus power 5 VDC, 1.4 A maximum
Ambient temperature range 0 to 60 °C
Memory positioning Full M5-class feature set with added memory for large batch and memory-intensive applications
Redundancy Supports redundant (paired) controller operation
Configuration migration Control strategies and configurations from earlier DeltaV systems are usable on the MD Plus
Listed origin (as supplied) Thailand and United Kingdom

 

Engineering Selection Highlights

  • Position in the DeltaV controller range: The MD Plus sits above the standard MD controller in memory capacity, aimed at large batch control and other memory-intensive strategies — so strategy size, not just I/O count, drives the choice between controller models.
  • Redundant operation: The controller supports redundant paired operation, which matters wherever a single controller failure would interrupt a continuous process.
  • Configuration continuity: Strategies and configurations created on earlier DeltaV systems can be used on the MD Plus, reducing re-engineering effort when controllers are renewed or expanded.
  • Power planning: The controller draws up to 1.4 A at 5 VDC from the LocalBus; power supply sizing for the controller carrier and its I/O must account for this load.
  • Thermal environment: The operating range of 0 to 60 °C ambient defines the cabinet ventilation requirement; installations above this range need cooling provisions.
  • I/O integration: As a DeltaV M-series controller, it works with the DeltaV I/O subsystem on the LocalBus — I/O types and counts should be checked against the overall node configuration.

 

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Control system Emerson DeltaV DCS Controller is defined entirely within the DeltaV architecture
Controller series M-series; MD Plus class Select controller model by strategy size and application type
Redundancy Supports redundant controller operation Redundant pairs require matching controllers and configuration
I/O subsystem DeltaV I/O on the LocalBus I/O module types and counts must fit the node configuration
Power 5 VDC LocalBus, max 1.4 A Include in the node power budget
Engineering Control strategies and configurations from earlier DeltaV systems are usable Verify version compatibility during migration
Environment 0 to 60 °C ambient Cabinet cooling must hold the controller within range

 

Detailed Product Overview

The VE3006 is the MD Plus controller of Emerson’s DeltaV system, belonging to the M-series hardware generation. In a DeltaV node, the controller is the working heart of the cabinet: it holds the downloaded control strategy, executes it on a scheduled basis, and handles the data exchange with the I/O modules that terminate the field wiring. Everything else in the node — power supplies, I/O carriers, communication interfaces — exists to support that execution.

What distinguishes the MD Plus within the M-series is capacity. Emerson’s positioning for the controller is explicit: it provides all the features and functions of the M5-class controller, with the additional memory needed for large batch and other memory-intensive applications. In practice, that distinction shows up in project engineering: a node whose strategy consists of extensive batch sequences, many control modules, or large amounts of computed data will exhaust a smaller controller’s memory before exhausting its I/O capacity. Choosing the MD Plus for such nodes trades a small increment in hardware cost for headroom in strategy size.

The second engineering property is availability. The MD Plus supports redundant controller operation: two controllers operate as a pair, with the standby taking over if the primary fails. For continuous processes — where the controlled unit cannot simply stop while a controller is replaced — this capability is often the reason a node is engineered with MD Plus controllers from the outset. When replacing a controller in an existing redundant pair, the replacement must match the node configuration so the pair synchronizes correctly.

The remaining constraints are electrical and environmental. The controller draws up to 1.4 A at 5 VDC from the LocalBus, which is a line item in the node’s power budget, and it operates in ambients of 0 to 60 °C, which sets the cooling requirement for the cabinet. One further point matters for maintenance planning: control strategies and system configurations created on earlier DeltaV systems can be used with the MD Plus, so controller renewal does not force strategy re-engineering. Procurement should confirm the hardware part number (such as KJ2003X1-BB1 / 12P3439X) against the node configuration before ordering, since DeltaV hardware generations differ in compatibility details.

VE3006

VE3006

VE3006

VE3006

Applications & System Role

In the DeltaV architecture, the controller is the node-level execution engine: the engineering workstation downloads control strategies to it, and it executes those strategies continuously while exchanging I/O data with the field via the I/O subsystem on its LocalBus. Above the controller, the DeltaV control network connects it to operator stations and the engineering system; below it, the I/O carriers host the input/output modules that connect to field instruments and devices.

The MD Plus variant addresses the segment of that workload where the control strategy itself is large — batch applications with extensive phase logic, units with many control modules, or otherwise memory-intensive configurations. Its support for redundant operation makes it suited to nodes whose control functions cannot tolerate a single-controller outage, with the standby controller taking over execution when the primary fails. These are fit scenarios derived from the controller’s documented capabilities, not claims about specific installed plants.

 

FAQ

What is the Emerson VE3006?
It is the DeltaV MD Plus controller, an M-series controller module of Emerson’s DeltaV distributed control system, supplied under hardware part numbers including KJ2003X1-BB1 (12P3439X).

What does the DeltaV controller do?
It executes the control strategies downloaded from the DeltaV engineering system and manages data exchange with the I/O modules connected on its LocalBus.

How does the MD Plus differ from other DeltaV controllers?
It provides the full feature set of the M5-class controller with additional memory, aimed at large batch and other memory-intensive control applications.

Can the VE3006 operate redundantly?
Yes — the MD Plus supports redundant (paired) controller operation, allowing a standby controller to continue control if the primary fails.

What are the power and environmental requirements?
The controller draws up to 1.4 A at 5 VDC on the LocalBus and operates in ambient temperatures from 0 to 60 °C.

Can existing DeltaV strategies be used on the VE3006?
Yes — control strategies and system configurations created on earlier DeltaV systems can be used with the MD Plus controller.