Description
Core Product Summary (Brand / Model / Key Attributes)
The Emerson VE3007 (Assembly Part Number: KJ2003X1-BA1) is an 8-channel 4–20 mA analog output card designed for the Emerson DeltaV Distributed Control System (DCS). Operating within DeltaV Traditional I/O carrier assemblies, it drives control valves, variable frequency drives (VFDs), current-to-pressure (I/P) transducers, and analog positioners across industrial process automation systems.
Configured for standard 4–20 mA DC current loops, the VE3007 delivers high-accuracy output signals to field actuators. Each of its 8 channels features galvanic optical isolation to protect the internal DeltaV local bus from field noise, ground loops, and electrical transients. The card supports full hot-swapping under live system power and provides HART pass-through capability, allowing plant software to communicate directly with smart field devices without interrupting the analog control signal.
Key Technical Specifications
| Parameter | Specification |
| Model Number | VE3007 |
| Assembly Part Number | KJ2003X1-BA1 |
| Manufacturer | Emerson (DeltaV System) |
| Product Family | DeltaV Traditional I/O Series |
| Module Type | 8-Channel 4–20 mA Analog Output Card |
| Number of Channels | 8 Analog Outputs |
| Output Signal Range | 4 to 20 mA DC |
| Protocol Support | HART Pass-Through (HART transparent) |
| Isolation | Optical isolation between field terminals and system backplane |
| Module Insertion | Hot-swappable in energized DeltaV I/O carriers |
| Status Indicators | Front panel LEDs for power, card health, and channel activity |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
Detailed Product Overview
The Emerson VE3007 / KJ2003X1-BA1 analog output module serves as a primary control output card for the DeltaV automation system. Engineed for continuous process industries such as chemical manufacturing, oil refining, pulp and paper, and power generation, the card converts digital control commands from DeltaV controllers into precise 4–20 mA current signals.
Each of the 8 channels operates independently with dedicated digital-to-analog converters (DACs) and signal conditioning microcircuits. Onboard hardware filtering suppresses electrical noise and voltage ripple on field loop lines. Optical isolation separates field wiring terminals from the internal system local bus, protecting sensitive controller components against high-voltage surges and field ground potential differences.
The VE3007 card installs into standard slots on DeltaV 8-slot or 2-slot I/O carriers. Full hot-swap functionality allows technicians to remove or replace an active card under live system power without disrupting adjacent operational I/O modules or interrupting controller logic execution. Front-panel LED indicators display card power and operational diagnostic health to simplify routine maintenance and commissioning inspections.
Engineering Selection Highlights
- 8-Channel High Density → Consolidates 8 independent 4–20 mA analog output loops into a single DeltaV carrier slot to maximize cabinet space efficiency.
- HART Pass-Through Support → Allows smart HART valve positioners and field instruments to transmit digital diagnostic data transparently to DeltaV AMS Device Manager software.
- Galvanic Optical Isolation → Prevents ground loops and protects backplane electronics from industrial noise spikes and field voltage transients.
- Hot-Swappable Module Architecture → Can be inserted or removed under live system power, reducing process downtime during loop maintenance or card replacement.
- Native DeltaV System Sensing → Automatically detected and configured within DeltaV Explorer, enabling fast I/O loop assignment and parameter configuration.

VE3007

VE3007
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Host Platform | Emerson DeltaV Distributed Control System | Plugs into standard DeltaV 8-slot or 2-slot Traditional I/O Carriers. |
| Required Terminal Block | DeltaV 8-Channel Field Terminal Block | Connects to matching DeltaV 8-channel terminal blocks (screw or mass termination versions). |
| Power Supply | 24 V DC Field Power | Field loops require a 24 V DC bulk power source routed through the carrier terminal block. |
| Configuration Tool | DeltaV Engineering & AMS Device Manager | Auto-sensed by DeltaV Explorer; HART parameters managed via AMS Device Manager. |
Dimensions, Mounting & Connection Notes
- Mounting: Snaps into dedicated card slots on DeltaV I/O carriers mounted on standard 35 mm DIN rails.
- Carrier Insertion: Align internal card guides and push firmly until the top and bottom retention latches engage into place.
- Terminal Connections: Field loop cables terminate at the dedicated DeltaV 8-channel terminal block positioned directly below the card slot.
- Hot-Swap Procedure: Depress the top and bottom card latches simultaneously and pull the module straight out from the carrier. Insert the replacement VE3007 card directly into the live slot.
FAQ
What is the difference between VE3007 and KJ2003X1-BA1?
VE3007 is the model number for the DeltaV 8-channel 4–20 mA analog output card, whereas KJ2003X1-BA1 is the physical hardware assembly part number printed on the printed circuit board.
Does the VE3007 module support HART communication?
Yes, the VE3007 features HART pass-through capabilities, allowing digital HART signals from smart valve positioners to pass through to DeltaV AMS software.
How many output channels are provided on the VE3007 card?
The VE3007 card provides 8 independent 4–20 mA analog output channels.
Can the VE3007 card be hot-swapped during live operation?
Yes, the card is fully hot-swappable and can be removed or replaced without turning off system power or disrupting adjacent I/O modules.
What terminal block is required for the VE3007?
It requires a compatible DeltaV 8-channel field terminal block (screw terminal or mass header type) installed on the carrier slot.
Verification & Troubleshooting Notes
Field Loop Power & Fusing Notice
Verify that 24 V DC auxiliary loop power supply polarity and external fuses are correctly installed on the terminal block assembly before energizing field loops. Reverse wiring or overvoltage can cause permanent damage to output channel circuitry.
1.Physical & Power Check:Verify Card Seating and Power LED.
Insert the VE3007 card firmly into the DeltaV carrier slot until retaining latches engage. Observe the top green POWER / CARD OK LED on the faceplate.
Verification: The green Power LED illuminates steadily, confirming proper internal backplane power delivery.
2.Software & Diagnostics Check:Verify Auto-Sensing in DeltaV Explorer.
Open DeltaV Explorer on the engineering workstation and navigate to the assigned carrier slot address.
Verification: The VE3007 card displays online status without diagnostic error icons or hardware mismatch warnings.
3.Signal Verification:Test 4–20 mA Current Loop Output.
Use DeltaV Control Studio or diagnostic test panels to command a test current output (e.g., 4 mA, 12 mA, 20 mA) to a specific channel while measuring current across the field terminals with a calibrated multimeter.
Verification: The measured loop current matches the commanded software value within standard tolerance limits.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626