The Emerson VE4002S2T2B8 is a 32-channel discrete output card designed for the DeltaV distributed control system. Operating within the DeltaV Traditional I/O subsystem, this Series 2 Plus module delivers digital signal control for process automation applications by sourcing 24V DC power through high-side switching mechanisms to field-actuated hardware.
This card features 32 independent output channels utilizing optical isolation to safeguard system electronics from field-side transients. Designed to pair with a matching 32-channel discrete output terminal block on DeltaV I/O interface carriers, the VE4002S2T2B8 receives 12V DC power from the LocalBus carrier backplane while managing high-density field wiring through external 24V DC field circuits.
Key Technical Specifications
| Parameter | Specification |
| Manufacturer | Emerson |
| Model / Part Number | VE4002S2T2B8 |
| System Family | DeltaV Traditional I/O |
| Module Type | Discrete Output Card (Series 2 Plus) |
| Channel Density | 32 Channels |
| Output Signal Type | 24V DC High-Side Switching |
| Output Current Rating | 1.0 A per channel maximum (3.0 A maximum per interface group) |
| Off-State Leakage Current | 1.2 mA maximum |
| Channel Isolation | Optical isolation, factory tested up to 1500V DC |
| LocalBus Power Consumption | 100 mA typical, 150 mA maximum (12V DC nominal) |
| Field Circuit Voltage | 24V DC nominal |
| Max Field Current Supply | 3.0 A maximum at 24V DC |
| Operating Temperature Range | -40°C to +70°C (-40°F to +158°F) |
| Storage Temperature Range | -40°C to +85°C (-40°F to +185°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Environmental Protection | IP20 rating; G3 conformal coating option available |
| Mechanical Shock / Vibration | 10 g half-sine wave (11 ms); 1 mm peak-to-peak (5–16 Hz), 0.5 g (16–150 Hz) |
Detailed Product Overview
The Emerson VE4002S2T2B8 high-density discrete output card acts as an executive switching interface between the DeltaV digital controller and binary field devices such as solenoids, indicator lamps, relay coils, and motor starters. Installed within the DeltaV I/O carrier structure, the card receives control commands across the redundant LocalBus communication channel and energizes field loads via solid-state high-side switches. High-side switching ensures that when a channel is active, 24V DC power is driven to the field terminal, keeping the load grounded at the field instrument side.
Each of the 32 discrete channels incorporates optical isolation to protect internal logic circuitry from high-voltage field spikes and ground potential differences up to 1500V DC. This electrical isolation prevents field-generated noise from interfering with the controller’s backplane processing. The card relies on two distinct power sources: internal logic is powered directly through the carrier backplane’s 12V DC LocalBus current, whereas field output switching relies on an auxiliary bulk 24V DC power supply landed at the terminal base.
The VE4002S2T2B8 is designed with mechanical polarization and system protection keys to prevent incorrect card insertion into non-matching carrier slots or terminal blocks. In high-density cabinet layouts, the high channel count per slot maximizes carrier real estate while providing standard signal processing across automated process control loops.

VE4002S2T2B8

VE4002S2T2B8
Engineering Selection Highlights
- High-Density Channel Layout: 32 output channels in a single slot reduce total carrier backplane requirements and cabinet space footprint.
- High-Side Switching Architecture: Drives 24V DC directly to connected field loads, matching standard positive-logic control schemes for relays and solenoid valves.
- Optical Transient Protection: 1500V DC channel-to-system isolation shields DeltaV controller hardware from electrical faults occurring in field wiring.
- Dual Power Architecture: Separates low-voltage LocalBus logic power (12V DC) from high-power field circuit supply (24V DC), maintaining system stability if field power is lost.
- Mechanical Keying Compatibility: Integrates mechanical protection keys to restrict module insertion exclusively to correctly configured terminal bases.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Automation System | Emerson DeltaV DCS | Works within the DeltaV control architecture |
| Subsystem Series | Traditional I/O Series 2 Plus | Must be installed on Series 2 compatible carriers |
| Carrier Mounting | DeltaV 2-wide / 8-wide I/O Interface Carriers | Plugs directly into standard DIN-rail mounted carriers |
| Terminal Block | 32-Channel DO Terminal Block | Requires a 32-channel terminal block for field wiring connection |
| Backplane Power | DeltaV LocalBus (12V DC) | Draws up to 150 mA maximum from carrier bus |
| External Power | Bulk 24V DC Field Power Supply | Auxiliary 24V DC field power must be landed at the terminal block |
| Engineering Software | DeltaV Explorer / Control Studio | Configured via standard DeltaV software system hardware trees |
Dimensions, Mounting & Connection Notes
- Height: 10.7 cm (4.2 in.)
- Width: 4.1 cm (1.6 in.)
- Depth: 10.5 cm (4.1 in.)
- Mounting Method: Direct snap-in insertion onto a DeltaV I/O interface carrier mounted on standard T-section DIN rails (EN 50022).
- Clearance Requirements: Maintain standard vertical ventilation space above and below the I/O carrier assembly to ensure natural convection cooling within industrial enclosures.
- Terminal Wiring: Field connections land on the associated 32-channel terminal block using screw or spring-clamp terminals, accommodating standard field wiring gauges.
- Grounding: Functional system grounding is established automatically through the I/O carrier grounding bar upon mechanical installation.
FAQ
What is the Emerson VE4002S2T2B8?
The Emerson VE4002S2T2B8 is a 32-channel 24V DC discrete output card used in the DeltaV distributed control system to switch binary field devices.
What switching type does the VE4002S2T2B8 use?
The module uses high-side switching, sourcing positive 24V DC power to connected field loads when an output channel is energized.
How many channels does the VE4002S2T2B8 support?
It supports 32 individual discrete output channels on a single module.
What power sources are required for operation?
The module requires 12V DC power from the LocalBus backplane for internal processing, plus external 24V DC bulk field power connected to the terminal block to energize output loads.
What terminal block is required for installation?
The VE4002S2T2B8 requires a compatible DeltaV 32-channel discrete output terminal block mounted on an I/O interface carrier.
Is channel isolation provided on this module?
Yes, each channel is optically isolated from the internal system logic and factory tested to 1500V DC.
Verification & Troubleshooting Notes
- Module Status Indicators: Observe the card’s front-panel status LEDs. A solid green status light confirms normal LocalBus communication and active controller communication, while red or flashing states indicate bus communication errors or internal self-test failures.
- Field Wiring Voltage Check: Measure voltage between the individual output terminal and the 24V DC field return ground when the output is commanded ON. Absence of 24V DC during an active state points to blown field fuses, missing bulk 24V DC supply, or open circuit conditions.
- Off-State Leakage Verification: Solid-state switches exhibit a maximum off-state leakage current of 1.2 mA. If low-power field indicators remain faintly illuminated when turned off, check if the load impedance requires a parallel bleeder resistor to sink residual leakage.
- Carrier Polarization Keying: If the module fails to seat smoothly into the terminal block base, verify that the mechanical keying pins on the carrier match the physical slots of the VE4002S2T2B8. Do not force insertion.
- Current Limitation Monitoring: Ensure total current load across output channels does not exceed the maximum rating of 3.0 A per interface group. Overcurrent conditions can trigger thermal protection shutoffs on output channels.