Description
Core Product Summary
The Emerson VE4006P2 is a two-port Serial Interface Card assembly for the DeltaV M-series Distributed Control System. It provides a communication interface between the DeltaV controller and external equipment using serial communication protocols. The ordering configuration includes one serial interface card and one simplex terminal block.
Both serial ports support RS-232, RS-422/485 half-duplex, and RS-422/485 full-duplex signaling. The interface supports Modbus RTU and Modbus ASCII, with each port independently configurable as a master or slave. Its 32-data-set capacity, divided into 16 data sets per port, allows serial device information to be incorporated into DeltaV control modules, operator displays, and process monitoring functions.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Emerson |
| Model | VE4006P2 |
| Product Type | M-series Serial Interface Card |
| Product Family | DeltaV M-series |
| Number of Serial Ports | 2 |
| Included Hardware | 1 Interface Card and 1 Simplex Terminal Block |
| Serial Interfaces | RS-232, RS-422/485 Half Duplex, RS-422/485 Full Duplex |
| Maximum Communication Rate | 115,200 baud |
| Data Sets per Card | 32 |
| Data Sets per Port | 16 |
| Supported Protocols | Modbus RTU, Modbus ASCII |
| Port Configuration | Individually configurable |
| Modbus Operating Mode | Master or Slave |
| Port Isolation | Each port isolated from the system and from the other port |
| External Grounding | Required for the isolated ports |
| Baud Rate Settings | 300 to 115,200 baud |
| Parity | Even, Odd, None |
| Data Bits | 7 or 8 |
| Stop Bits | 1 or 2 |
| Retry Count | 0–255 |
| Message Timeout | 100–25,500 ms |
| Transmit Delay | 0–25,500 ms |
| Operating Temperature | -40 to 70°C |
| Storage Temperature | -40 to 85°C |
| Relative Humidity | 5–95%, non-condensing |
| Protection Rating | IP20 |
| Shock Resistance | 10 g, half-sine wave, 11 ms |
| Airborne Contaminants | ISA-S71.04-1985 Class G3 |
Engineering Selection Highlights
- Two independent serial ports: Each port can be configured separately, allowing the interface to communicate with two serial connections within the same DeltaV I/O assembly.
- Multiple electrical interface options: RS-232 and RS-422/485 support different serial wiring arrangements. The selected mode must match the connected equipment’s electrical interface.
- Modbus RTU and ASCII support: The standard Modbus drivers provide a communication path for compatible external devices. Each port can operate as a master or slave.
- 32-data-set capacity: The interface supports 16 data sets per port, providing a structured method of exchanging serial information with the DeltaV controller.
- Independent port isolation: Each serial port is isolated from the system and the other port. External grounding is required, which must be considered during cabinet wiring.
- M-series carrier compatibility: The interface uses the DeltaV M-series I/O carrier architecture and is compatible with MQ, MX, and PK controllers.
- Simplex terminal-block configuration: VE4006P2 includes one interface card and one simplex terminal block. It should not be confused with the redundant two-card configuration.

VE4006P2

VE4006P2
System Compatibility & Integration Requirements
| Item / Dependency | Compatibility or Requirement | Practical Note |
|---|---|---|
| Control System | Emerson DeltaV DCS | Designed for DeltaV serial communication integration |
| I/O Architecture | M-series Traditional I/O | Uses the M-series I/O interface carrier |
| Controller Compatibility | MQ, MX, PK controllers | Confirm the installed controller configuration |
| I/O Carrier | M-series I/O interface carrier | Installed in an available compatible carrier slot |
| Serial Ports | 2 ports | Each port is independently configurable |
| Electrical Interfaces | RS-232, RS-422/485 | Match the wiring arrangement to the connected device |
| Standard Protocols | Modbus RTU and Modbus ASCII | Both communication modes are supported |
| Data Exchange | 32 data sets total | 16 data sets per serial port |
| Terminal Block | Simplex terminal block | Included in the VE4006P2 ordering configuration |
| Custom Protocols | Additional serial drivers | Custom drivers may be available for supported equipment |
| Grounding | External grounding required | Both isolated serial ports require appropriate grounding |
Important controller compatibility limitation: DeltaV M-series I/O cards are not compatible with S-series controllers and I/O carriers. VE4006P2 should therefore be selected for an appropriate M-series installation rather than assumed to fit an S-series architecture.
Dimensions, Mounting & Connection Notes
VE4006P2 uses the DeltaV M-series I/O interface carrier mounting architecture.
Key installation considerations:
- The assembly consists of one serial interface card and one simplex terminal block.
- The interface card fits into an available slot on a compatible M-series I/O interface carrier.
- Two serial communication ports are provided.
- Each port supports RS-232 and RS-422/485 communication modes.
- Each port is electrically isolated from the system and the other port.
- External grounding is required for the isolated ports.
- Communication parameters must match the connected field device.
The serial configuration should include the correct baud rate, parity, data bits, stop bits, retry count, and message timeout. RS-422/485 wiring must also match the selected half-duplex or full-duplex operating mode.
Detailed Product Overview
Two-Port Serial Communication Architecture
The Emerson VE4006P2 is designed to connect the DeltaV M-series control environment with external serial devices. Its two-port configuration provides two independent communication paths within one interface card.
The available electrical interfaces include RS-232, RS-422/485 half duplex, and RS-422/485 full duplex. These options address different physical communication arrangements. RS-232 is commonly associated with point-to-point serial connections, while RS-422/485 supports other serial network topologies depending on the equipment and wiring configuration.
The two ports are individually configurable, allowing their communication parameters to be established according to the requirements of the connected devices.
Modbus Data Exchange
Modbus RTU and Modbus ASCII are supported by the standard Modbus communication drivers.
The interface can operate each port as either a master or a slave. In master operation, it can initiate communication with a compatible device and retrieve or write the required register information. In slave operation, it responds to communication requests from an external master.
Supported data operations include:
- Reading Modbus coils and input status.
- Reading holding registers and input registers.
- Writing output data to coils.
- Writing output data to holding registers.
- Transferring information through configured data sets.
This architecture allows external device information to be incorporated into DeltaV control modules without treating every serial data point as a separate physical I/O channel.
Data-Set Organization and Controller Integration
VE4006P2 supports 32 data sets in total, with 16 data sets assigned to each serial port.
These data sets provide an organized interface between serial communication and the DeltaV control environment. Register information can be referenced by control modules as analog or discrete I/O, depending on the configured data structure.
The communication data can also be used for operator display and supervisory monitoring. This is relevant when a plant requires information from external PLCs, analyzers, or other serial equipment to be available through its centralized control architecture.
Redundancy and Hardware Configuration
VE4006P2 is supplied as a simplex configuration consisting of one interface card and one simplex terminal block.
DeltaV M-series Serial Interface technology also supports a separate redundant architecture using two serial interface cards and a redundant terminal block. Redundant operation includes automatic switchover between active and standby cards.
The redundant hardware arrangement is a separate ordering configuration and should not be assumed to be included with VE4006P2.
Installation and Communication Configuration
During commissioning, the serial interface must be configured to match the connected equipment.
Important communication parameters include baud rate, parity, data bits, stop bits, retry count, message timeout, and transmit delay. The supported baud-rate settings extend from 300 to 115,200 baud.
Electrical wiring must also match the selected RS-232 or RS-422/485 mode. Because the ports are individually isolated, their external grounding requirements should be incorporated into the cabinet wiring design.
For replacement or expansion projects, checking the installed M-series carrier, terminal-block configuration, serial wiring, and device communication settings is essential before integrating the interface into the control system.
Applications & System Role
The Emerson VE4006P2 occupies the serial communication layer of the DeltaV control architecture. It connects the DeltaV system with external devices that exchange information through supported serial interfaces.
Its function is particularly relevant when equipment cannot communicate directly through the standard DeltaV I/O signal architecture.
PLC-to-DCS communication
VE4006P2 can provide a serial data path between DeltaV and compatible PLC equipment. Data exchanged through the serial interface can be referenced by DeltaV control modules for supervisory coordination between control systems.
Modbus device integration
The interface supports Modbus RTU and ASCII communications. It can read input information from coils, input status, holding registers, and input registers, and write output information to coils and holding registers.
Analyzer and instrumentation integration
Serial data from compatible analyzers and other data sources can be organized into data sets. These values can then be incorporated into DeltaV control and monitoring structures.
Legacy serial equipment integration
The serial interface provides a connection between DeltaV and existing equipment with supported serial communication capabilities. This allows serial device information to be incorporated into a centralized control environment without assuming that the external device uses a native DeltaV I/O interface.
Frequently Asked Questions
Q1: What is the Emerson VE4006P2?
Emerson VE4006P2 is a two-port serial interface assembly for the DeltaV M-series Distributed Control System. It includes one interface card and one simplex terminal block.
Q2: How many communication ports does VE4006P2 have?
It has two individually configurable serial communication ports.
Q3: Which communication interfaces does VE4006P2 support?
It supports RS-232, RS-422/485 half duplex, and RS-422/485 full duplex.
Q4: Does VE4006P2 support Modbus communication?
Yes. Its standard Modbus drivers support Modbus RTU and Modbus ASCII. Each serial port can be configured as a master or slave.
Q5: How many data sets can VE4006P2 handle?
The interface supports 32 data sets in total, with 16 data sets per serial port.
Q6: Which DeltaV controllers are compatible with VE4006P2?
The M-series Serial Interface family is compatible with MQ, MX, and PK controllers. It is not compatible with S-series controllers and I/O carriers.
Q7: Does VE4006P2 support redundant communication?
The VE4006P2 ordering configuration is simplex. DeltaV M-series serial interface technology also supports a separate redundant configuration using two interface cards and a redundant terminal block.
Q8: What should be checked before replacing VE4006P2?
Check the exact model, DeltaV M-series carrier, simplex terminal block, serial interface type, field wiring, communication protocol, and configured port parameters.