Sale!

Emerson VE4031S2T2B6 Redundant 32-Channel DI Terminal Block

Parameter Specification
Brand Emerson
Model VE4031S2T2B6
Product Type Redundant Digital Input Terminal Block
Product Family DeltaV M-series Traditional I/O
I/O Generation Series 2 Plus
Associated Input Card Discrete Input Plus Card
Channel Capacity 32 channels
Categories: , , , , SKU: VE4031S2T2B6 Brand:

Description

Core Product Summary

The Emerson VE4031S2T2B6 is a redundant 32-channel digital input termination block for the DeltaV M-series Traditional I/O system. It is designed for the Series 2 Plus Discrete Input architecture, which supports 32-channel, 24 V DC dry-contact signals. The terminal block provides the field wiring interface for a redundant input-card arrangement.

Its redundant configuration allows two compatible DI Plus cards to operate as an active and standby pair through the same field termination arrangement. This architecture supports automatic switchover when the active card encounters a detected fault. For equipment selection, the key distinction is the B6 configuration: VE4031S2T2B6 is the redundant 32-channel terminal block, whereas VE4001S2T2B6 is the corresponding simplex configuration.

 

Key Technical Specifications

Parameter Specification
Brand Emerson
Model VE4031S2T2B6
Product Type Redundant Digital Input Terminal Block
Product Family DeltaV M-series Traditional I/O
I/O Generation Series 2 Plus
Associated Input Card Discrete Input Plus Card
Channel Capacity 32 channels
Signal Type 24 V DC dry contact
I/O Direction Digital Input
Redundancy Configuration Redundant input-card arrangement
Terminal Block Category DI Plus 32-Channel Terminal Block
System Architecture M-series Traditional I/O

 

Engineering Selection Highlights

  • 32-channel digital input configuration: Designed for the Series 2 Plus DI architecture, allowing 32 discrete input points to be connected through the associated input interface.
  • 24 V DC dry-contact signals: The associated DI Plus card is designed for dry-contact input signals. Field device electrical characteristics must match the input card requirements.
  • Redundant hardware arrangement: Supports a pair of compatible input cards, providing an active and standby input path within the DeltaV I/O architecture.
  • Automatic card switchover: DeltaV redundant I/O supports automatic transfer to the standby card when a qualifying hardware or communication fault is detected.
  • Shared field termination arrangement: Redundant terminal blocks provide the same field wiring connections as their simplex counterparts, avoiding additional field wiring solely because of the redundant card arrangement.
  • Series 2 Plus identification: The B6 terminal-block designation identifies the 32-channel DI Plus configuration and should be retained when matching installed hardware.

 

System Compatibility & Integration Requirements

Item / Dependency Compatibility or Requirement Practical Note
Control System Emerson DeltaV DCS M-series Traditional I/O architecture
I/O Generation Series 2 Plus Intended for the DI Plus hardware configuration
Input Card 32-channel DI Plus card 24 V DC dry-contact input
Redundancy Two compatible input cards Active and standby arrangement
I/O Carrier M-series horizontal or VerticalPlus carrier Select the carrier for the installed M-series architecture
Field Signal 24 V DC dry contact Confirm field device and input card electrical compatibility
Terminal Block Redundant 32-channel DI Plus terminal block Match the B6 configuration
Engineering Software DeltaV configuration environment The associated DI Plus card requires DeltaV v13.3.1 or later

Important integration considerations

  1. VE4031S2T2B6 should be selected for a redundant DI Plus arrangement, not as a generic replacement for every 32-channel digital input terminal block.
  2. The associated input cards must have the correct function keying for the terminal block.
  3. M-series horizontal I/O carriers are not physically compatible with S-series horizontal controller carriers.
  4. The redundant configuration should be commissioned with both input paths and automatic switchover behavior checked.
VE4031S2T2B6

VE4031S2T2B6

VE4031S2T2B6

VE4031S2T2B6

Dimensions, Mounting & Connection Notes

VE4031S2T2B6 belongs to the DeltaV M-series Traditional I/O terminal-block architecture.

Relevant installation considerations:

  • The terminal block is installed on a compatible M-series I/O interface carrier.
  • The associated DI Plus cards must match the terminal block’s function keying.
  • The redundant arrangement accommodates two compatible input cards.
  • Field wiring follows the 32-channel DI Plus terminal-block configuration.
  • The associated input architecture uses 24 V DC dry-contact signals.

During installation or replacement, retain the existing field channel assignments and terminal identification. Verify the installed carrier, card keying and redundant configuration before removing the existing assembly.

 

Detailed Product Overview

Product Function in DeltaV M-Series

The Emerson VE4031S2T2B6 is a field termination component for the DeltaV M-series Series 2 Plus digital input subsystem.

Unlike an electronic DI card, the terminal block does not independently acquire or process field signals. Its role is to provide the electrical connection between field wiring and the associated input electronics.

The corresponding DI Plus architecture supports 32 discrete input channels operating with 24 V DC dry-contact signals. This channel density allows a group of discrete field signals to be integrated through a single I/O interface.

Redundant Input Configuration

The defining characteristic of VE4031S2T2B6 is its redundant terminal-block arrangement.

DeltaV M-series redundant I/O uses two compatible input cards configured as an active and standby pair. The controller monitors the card arrangement and determines which card is operating as the active interface.

When a qualifying fault occurs, the system automatically transfers operation to the standby card. The system also provides hardware status information through its diagnostic functions.

For maintenance planning, this distinction matters because replacing a redundant terminal block is not equivalent to replacing a simplex terminal block. The replacement must preserve the installed redundancy architecture.

Series 2 Plus and Field Wiring

VE4031S2T2B6 is specifically associated with the Series 2 Plus 32-channel DI configuration.

The corresponding simplex terminal-block model is VE4001S2T2B6. The redundant version maintains the same field wiring connection arrangement while accommodating the redundant input-card configuration.

This design helps separate the field wiring requirement from the electronics redundancy requirement. The field wiring does not need to be duplicated solely because a second input card is installed.

The terminal block also incorporates the M-series function-keying concept. The keying arrangement helps prevent an incompatible I/O card from being installed in the terminal-block assembly.

Hardware Selection and Maintenance

When specifying VE4031S2T2B6 for an existing DeltaV installation, engineers should examine the complete I/O assembly rather than relying on channel count alone.

The following details are particularly important:

  • Confirm that the installed system uses M-series Traditional I/O.
  • Identify the associated Series 2 Plus DI input cards.
  • Confirm the 32-channel, 24 V DC dry-contact input configuration.
  • Check whether the existing installation uses redundant or simplex termination.
  • Retain the original field wiring assignments and terminal identification.
  • Confirm that the carrier and card keying match the intended assembly.

These checks help prevent confusion between terminal blocks that share similar physical designs but serve different I/O functions or redundancy arrangements.

 

Applications & System Role

Redundant Digital Input Acquisition

The VE4031S2T2B6 provides the field termination interface for a redundant digital input arrangement in a DeltaV M-series control system.

Digital inputs represent discrete equipment conditions, including contact states and switching information. These signals are acquired by the associated DI Plus cards and made available to the DeltaV control environment.

Equipment Status Monitoring

The 32-channel input architecture can accommodate multiple dry-contact status signals through one I/O interface. Depending on the field device and control configuration, these signals can represent:

  • Equipment running and stopped conditions.
  • Auxiliary contact status.
  • Switch and relay feedback.
  • Discrete equipment alarms.
  • Interlock status signals.

These are functional application examples of the associated digital input architecture, not documented customer deployments of this particular terminal block.

Redundant Control-System Architecture

In applications where loss of an input interface could affect process monitoring or control logic, redundant I/O provides an alternative hardware path.

The DeltaV system monitors the redundant input-card arrangement and can switch to the standby card when a qualifying fault occurs. The terminal block provides the common field wiring interface for this architecture.

 

Frequently Asked Questions

Q1: What is Emerson VE4031S2T2B6?

Emerson VE4031S2T2B6 is a redundant 32-channel digital input terminal block for the DeltaV M-series Series 2 Plus I/O system.

Q2: Which input card is associated with VE4031S2T2B6?

It is associated with the 32-channel DI Plus card designed for 24 V DC dry-contact signals.

Q3: Is VE4031S2T2B6 a simplex or redundant terminal block?

It is a redundant terminal block designed for a two-card input arrangement.

Q4: What is the difference between VE4031S2T2B6 and VE4001S2T2B6?

VE4031S2T2B6 is the redundant 32-channel DI Plus terminal block, while VE4001S2T2B6 is the simplex version.

Q5: How many input channels does the associated DI Plus configuration support?

The associated DI Plus card supports 32 digital input channels.

Q6: What signal type is supported by the associated input card?

The associated DI Plus input card is designed for 24 V DC dry-contact signals.

Q7: How does redundancy work in the DeltaV M-series architecture?

Two compatible input cards operate as an active and standby pair. When a qualifying fault is detected, DeltaV automatically switches to the standby card.

Q8: What should be checked before ordering VE4031S2T2B6?

Confirm the complete model number, M-series carrier, Series 2 Plus DI card configuration, 32-channel input requirement and redundant terminal-block arrangement.