Sale!

Emerson VE4050E2C0 DeltaV M-Series 8-Wide I/O Carrier

Parameter Specification
Brand Emerson
Model VE4050E2C0
Product Type I/O Interface Carrier
Product Family DeltaV M-series
Mounting Orientation Horizontal
Carrier Capacity 8 I/O cards
Terminal Block Capacity 8 terminal blocks
Extension Configuration Dual carrier extension cables
Extension Cable Length 1.2 m each
Categories: , , , , SKU: VE4050E2C0 Brand:

Description

Core Product Summary

The Emerson VE4050E2C0 is an 8-wide horizontal I/O interface carrier designed for the DeltaV M-series Distributed Control System. It provides the mounting and electrical interface for up to eight I/O cards and eight terminal blocks. This configuration includes a carrier shield bar and dual carrier extension cables, each measuring 1.2 m.

The carrier connects to the DeltaV power/controller carrier and extends the system I/O architecture. Its integrated connections support I/O communication, field power distribution, and terminal-block installation. The dual extension-cable arrangement allows the I/O carrier to be positioned separately from the power/controller carrier, supporting distributed cabinet layouts and multi-row installations.

 

Key Technical Specifications

Parameter Specification
Brand Emerson
Model VE4050E2C0
Product Type I/O Interface Carrier
Product Family DeltaV M-series
Mounting Orientation Horizontal
Carrier Capacity 8 I/O cards
Terminal Block Capacity 8 terminal blocks
Extension Configuration Dual carrier extension cables
Extension Cable Length 1.2 m each
Included Component Carrier shield bar
Mounting Method T-type DIN rail
Field Power Interface Bulk 24 V DC field instrument power
Backplane Current Rating 8 A maximum
Operating Temperature -40 to 70°C
Storage Temperature -40 to 85°C
Relative Humidity 5–95%, non-condensing
Airborne Contaminants ISA-S71.04-1985 Class G3
Shock Resistance 10 g, half-sine wave, 11 ms

 

Engineering Selection Highlights

  • Eight-slot I/O capacity: Accommodates eight I/O cards and eight terminal blocks, allowing multiple I/O functions to share one carrier assembly.
  • Dual extension-cable configuration: Includes two 1.2 m carrier extension cables, providing flexibility when arranging the I/O carrier and power/controller carrier in separate cabinet positions.
  • Horizontal mounting architecture: Designed for T-type DIN rail installation within the DeltaV M-series horizontal carrier system.
  • Integrated carrier shield bar: Provides a designated grounding and shielding arrangement to help manage field noise within the I/O subsystem.
  • Modular system expansion: Additional compatible 8-wide carriers can be connected to expand the I/O subsystem.
  • Separate field and system power functions: The carrier architecture provides connections for I/O backplane power and bulk 24 V DC field instrument power.
VE4050E2C0

VE4050E2C0

VE4050E2C0

VE4050E2C0

VE4050E2C0

VE4050E2C0

System Compatibility & Integration Requirements

Item / Dependency Compatibility or Requirement Practical Note
Control System Emerson DeltaV DCS M-series architecture
I/O Family M-series Traditional I/O Designed for M-series I/O cards
Mounting Orientation Horizontal T-type DIN rail mounting
Power/Controller Carrier DeltaV M-series power/controller carrier Provides system power and controller communication
I/O Capacity 8 I/O cards Maximum carrier capacity
Terminal Blocks 8 terminal blocks One terminal-block position per I/O card
Extension Cables Dual carrier extension cables Two cables, 1.2 m each
Shielding Carrier shield bar Integrated shielding and grounding arrangement
Field Power Bulk 24 V DC field instrument power Supplied through the carrier connections
System Expansion Additional M-series I/O carriers Supports modular I/O subsystem expansion

Important compatibility considerations

  • VE4050E2C0 belongs to the M-series horizontal carrier architecture.
  • M-series carriers are not physically compatible with S-series controller carriers, except when used with the DeltaV SIS Adapter.
  • The dual carrier extension arrangement is relevant to DeltaV SIS installations because the dual extender architecture can support the redundant safety bus.
  • The carrier must be matched to the corresponding M-series power/controller carrier and system configuration.

 

Dimensions, Mounting & Connection Notes

VE4050E2C0 is an eight-wide horizontal I/O interface carrier.

Physical installation

  • Mounting method: T-type DIN rail.
  • Carrier orientation: Horizontal.
  • Carrier capacity: Eight I/O cards and eight terminal blocks.
  • Extension cables: Two 1.2 m carrier extension cables.
  • Shielding: Integrated carrier shield bar.

Electrical and grounding considerations

The carrier provides connections for bulk 24 V DC field instrument power, I/O interfaces, and terminal blocks. Its integrated shield ground bar provides a separate path for managing field noise.

For cabinet design, the extension cables should be routed according to the installation layout and the applicable carrier installation instructions.

 

Detailed Product Overview

Carrier Architecture and System Function

The Emerson VE4050E2C0 is an I/O interface carrier within the DeltaV M-series horizontal mounting architecture.

Unlike an individual I/O module, it does not perform analog measurement, digital signal processing, or serial communication independently. Its function is to provide the physical mounting positions and electrical connections required by the I/O subsystem.

The carrier supports eight I/O cards and eight terminal blocks. Each I/O interface is installed in its designated position, with the associated terminal block providing the field connection point.

The carrier connects to the power/controller carrier, which distributes system power and communication between the controller and the I/O interfaces.

Dual Carrier Extension Configuration

One of the defining features of VE4050E2C0 is its dual carrier extension arrangement.

The product includes two carrier extension cables measuring 1.2 m each. These cables allow the I/O carrier to be positioned separately from the power/controller carrier.

This arrangement is useful when a control cabinet requires more flexible equipment positioning or when the I/O subsystem is distributed across multiple rows.

The dual extension architecture also has an important role in DeltaV SIS installations. Dual carrier extenders provide connections that support the redundant safety bus used by the Safety Logic Solvers.

It is important to distinguish VE4050E2C0 from VE4050E1C0, which uses a single enhanced carrier extender cable.

Field Power Distribution and Shielding

The M-series I/O carrier provides connections for bulk 24 V DC field instrument power, I/O interfaces, and terminal blocks.

The carrier architecture also incorporates a shield ground bar. This arrangement provides a designated grounding path for field shielding and helps separate field noise from system power distribution.

When planning an installation, engineers should consider the field power distribution arrangement, grounding scheme, cable routing, and the electrical requirements of the installed I/O cards.

System Expansion and Installation

The DeltaV M-series modular architecture supports expansion through additional I/O carriers.

Up to eight 8-wide I/O interface carriers, providing a maximum of 64 I/O interfaces, are supported by a single I/O subsystem.

For horizontal installations, local bus extenders allow the I/O bus to continue across different rows of carriers.

The carrier must be installed with the correct M-series power/controller hardware and according to the system’s carrier-position and slot-numbering requirements. This is particularly important when combining four-wide and eight-wide carriers in one subsystem.

Procurement Identification

When ordering VE4050E2C0, the complete model number should be retained.

The following configuration details distinguish this model:

  • Eight-wide horizontal I/O interface carrier.
  • Dual carrier extension cable arrangement.
  • Two 1.2 m extension cables.
  • Integrated carrier shield bar.

These characteristics make the model distinct from standard eight-wide carriers and single-extension configurations.

 

Applications & System Role

DeltaV I/O Subsystem Expansion

VE4050E2C0 serves as the physical and electrical mounting platform for an eight-position DeltaV M-series I/O assembly.

It connects to the power/controller carrier, which supplies system power and communication between the controller and I/O interfaces. The carrier provides the positions required for individual I/O cards and their corresponding terminal blocks.

Distributed Cabinet Layouts

The dual extension-cable configuration allows the I/O carrier to be installed away from the power/controller carrier.

This arrangement is useful when cabinet space, wiring access, or equipment positioning requires a multi-row hardware layout. The 1.2 m extension cables provide the connection between the carrier assemblies.

DeltaV SIS Hardware Architecture

The dual carrier extension arrangement is also relevant to DeltaV SIS installations. The dual extender architecture provides connections for the redundant safety bus used by Safety Logic Solvers.

For this application, the complete carrier and cable configuration must match the intended DeltaV SIS architecture.

Industrial Control Cabinet Integration

The carrier provides an organized mounting structure for DeltaV M-series control hardware, including:

  • Analog input and output cards.
  • Digital input and output cards.
  • Communication interface cards.
  • Corresponding field termination blocks.

The actual I/O functions depend on the cards installed in the carrier.

 

Frequently Asked Questions

Q1: What is the Emerson VE4050E2C0?

Emerson VE4050E2C0 is an eight-wide horizontal I/O interface carrier for the DeltaV M-series control system. It includes dual carrier extension cables and a carrier shield bar.

Q2: How many I/O cards can VE4050E2C0 accommodate?

It supports up to eight I/O cards and eight corresponding terminal blocks.

Q3: What is the function of the dual extension cables?

The two extension cables connect the I/O interface carrier to the power/controller carrier, allowing more flexible physical positioning within the control cabinet.

Q4: What is the length of the extension cables?

Each carrier extension cable is 1.2 m long.

Q5: Is VE4050E2C0 compatible with DeltaV M-series I/O cards?

Yes. It is designed for the DeltaV M-series I/O subsystem and accommodates compatible M-series I/O cards and terminal blocks.

Q6: Can VE4050E2C0 be used in a DeltaV SIS architecture?

Its dual carrier extension arrangement supports the redundant safety bus connection used in DeltaV SIS architectures. The complete installation must follow the applicable SIS hardware configuration.

Q7: What is the difference between VE4050E2C0 and VE4050E1C0?

VE4050E2C0 uses dual carrier extension cables, while VE4050E1C0 uses a single enhanced carrier extender cable.

Q8: What should be checked before ordering VE4050E2C0?