Core Product Summary
The EPRO PR6423/003-030 with CON021 is a complete eddy current measuring chain from Emerson’s EPRO machinery monitoring range: an 8 mm non-contact sensor probe plus the matching CON021 signal converter. On critical turbomachinery — steam, gas and hydro turbines, compressors, gearboxes, pumps and fans — the pair measures radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals without contacting the shaft.
This probe variant is built with an M10x1 case thread and a 55 mm case, supplied unarmored with an 8 m integral cable, no adapter plug, and a Lemo connector at the cable end. The converter energizes the probe and delivers the scaled output over a 0 to 20 kHz (-3 dB) frequency range with a rise time below 15 µs, so the DC gap voltage and superimposed dynamic vibration signal can be read by EPRO MMS monitoring modules. The sensor side provides a 2 mm linear range at 8 V/mm (±5% over 0 to 45 °C) and IP66 protection, with the sensor rated to +180 °C including its first metre of cable.
Key Technical Specifications
| Parameter | Value |
|---|---|
| System composition | 8 mm eddy current sensor PR6423/003-030 + CON021 signal converter |
| Probe configuration | M10x1 case thread, 55 mm case, unarmored, 8 m cable, no adapter plug, Lemo cable end |
| Linear measurement range | 2 mm (80 mils) |
| Initial air gap | 0.5 mm (20 mils) |
| Incremental scale factor (ISO) | 8 V/mm (203.2 mV/mil) ± 5% at 0 to 45 °C |
| Deviation from best fit straight line (DSL) | ± 0.025 mm (± 1 mil) at 0 to 45 °C |
| Minimum shaft diameter | 25 mm (0.79 in) |
| Target material (standard) | 42CrMo4 (AISI/SAE 4140) ferromagnetic steel |
| Sensor operating temperature (incl. 1 m cable) | ‘-35 °C to +180 °C |
| Cable and connector temperature | ‘-35 °C to +150 °C |
| Probe protection class | IP66 per IEC 60529 |
| Converter supply voltage | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) |
| Converter frequency response (-3 dB) | 0 to 20,000 Hz |
| Converter rise time | < 15 µs |
| Converter operating temperature | ‘-30 °C to +100 °C |
| Converter shock/vibration resistance | 5 g at 60 Hz, 25 °C |
| Converter protection class | IP20 |
| Converter housing | LMgSi 0.5 F22 |
| Probe-to-converter connection | Self-locking Lemo-P connector |
| Approvals (sensor) | CE, ATEX, IECEx, CSA; intrinsic safety (ia) and non-sparking (nA) |
Detailed Product Overview
The PR6423/003-030+CON021 is supplied as a working measurement channel rather than a bare component, which matters for procurement: the stated scale factor and linearity apply to the matched probe–cable–converter chain, so ordering the pair together keeps the calibration consistent. The probe is the sensing element; the CON021 provides the oscillator excitation, demodulates the impedance change produced by shaft motion, and outputs a DC voltage proportional to the average gap with the dynamic vibration component riding on it. One channel therefore serves both position monitoring (thrust, axial displacement) and dynamic radial vibration measurement.
Mechanically, this variant is the 55 mm case version of the M10x1 family. The longer case suits installations where the probe must reach through deeper bearing housings or where the holder geometry requires the extended sleeve; the 25 mm and 35 mm cases of sibling order codes do not interchange without checking the mounting drill-through. The cable is unarmored, so where the routing passes through areas exposed to mechanical damage, protective conduit should be planned at installation. With 8 m of integral cable and no adapter plug, the Lemo connector at the cable end mates with the converter’s self-locking Lemo-P input, and the total electrical cable length of the chain is what the 8 V/mm calibration refers to — cutting, extending, or substituting the cable changes the system scale factor.
Electrically, the converter needs a negative supply from the monitoring rack: either -23 to -32 V for the -4 to -20 V output range or -21 to -32 V for the -2 to -18 V range. The -2 to -18 V output corresponds to the standard gap voltage convention used across the EPRO monitor family, with the usual working point near the middle of the linear range at approximately -10 V. The converter’s 20 kHz bandwidth and sub-15 µs rise time preserve the dynamic content of high-speed machinery signatures, including keyphasor and speed pulses picked up from a toothed wheel or notch.
Accuracy is conditional in two ways that engineers should respect. First, the 8 V/mm scale factor and the ±0.025 mm linearity are guaranteed against 42CrMo4 (AISI/SAE 4140) steel and defined between 0 and 45 °C; shafts of other alloys or magnetically modified surfaces shift the sensitivity, and hot-bearing environments push the electronics of the measuring chain outside the window in which those tolerances are stated. Second, the target must be at least 25 mm in diameter for the 8 mm tip to see a full eddy current field; smaller shafts reduce the effective linear range. The IP66 probe rating supports permanent exposure to dust and hose-down environments, while the converter is IP20 and belongs inside a cabinet or enclosure.
The hazardous-area approvals carried by the sensor family (ATEX, IECEx, CSA, with intrinsic safety ia and non-sparking nA modes of protection) allow installation in classified areas when the converter and barrier arrangement follows the conditions of the approval documentation, with the temperature class depending on the ambient temperature at the point of installation.

PR6423/003-030 + CON021

PR6423/003-030 + CON021

PR6423/003-030 + CON021
Dimensions, Mounting & Connection Notes
- Case thread: M10x1 with a 55 mm case length on this order code; standard M10 hardware uses SW 8 mm wrench flats on the case and SW 17 mm flats on the mounting nut side.
- The probe is installed facing the shaft surface with a 0.5 mm (20 mils) initial air gap inside the 2 mm linear range, verified against the converter’s gap voltage during commissioning.
- The integral cable is unarmored with a 2.8 mm diameter and a minimum bending radius of 25 mm; the Lemo connector at the cable end is 11.0 mm in diameter.
- Sensor including 1 m of cable is rated -35 °C to +180 °C; the remaining cable and connector section is rated -35 °C to +150 °C.
- The probe reaches IP66 per IEC 60529; the CON021 converter is IP20 and must be mounted on a panel in a protected location using 4 × M5×20 screws.
- Cable length tolerance is 0 to +10% of the nominal 8 m.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor–converter pairing | PR6423/003-030 probe with CON021 eddy current signal converter | The chain is calibrated as a matched probe–cable–converter set |
| Converter supply | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) | Supplied by the monitoring system, not a separate PSU unless specified |
| Probe connection | Self-locking Lemo-P connector on the converter | Mates with the probe’s Lemo cable end |
| Converter mounting | Panel mounting with 4 × M5×20 screws | Converter is IP20; install in a protected cabinet |
| Monitoring system | Output feeds EPRO MMS series monitoring modules | Converter output range must match the monitor input channel configuration |
| Measured target | 42CrMo4 (AISI/SAE 4140) steel, minimum shaft diameter 25 mm | Other materials require recalibration of the chain |
| Mechanical fit | M10x1 thread, 55 mm case | Verify holder depth; sibling codes use 25/35/45 mm cases |
| Cable routing | 8 m integral unarmored cable, Lemo end | Preserve total cable length; the 8 V/mm calibration applies to the full chain |
FAQ
What is the EPRO PR6423/003-030+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: an 8 mm non-contact sensor probe with an 8 m cable and Lemo termination, paired with the CON021 signal converter that drives it.
What is measured with this system?
The system measures radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals on rotating machinery such as steam, gas and hydro turbines, compressors, gearboxes, pumps and fans.
How is this probe variant configured?
It has an M10x1 case thread with a 55 mm case, an unarmored 8 m integral cable, no adapter plug, and a Lemo connector at the cable end.
What are the key measurement specifications?
The chain provides a 2 mm linear range, a 0.5 mm initial air gap, an 8 V/mm incremental scale factor ±5% over 0 to 45 °C, and a deviation from best fit straight line of ±0.025 mm over the same temperature range.
What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.
How fast can the system respond?
The converter has a frequency response of 0 to 20,000 Hz (-3 dB) and a rise time below 15 µs, which preserves the dynamic vibration content of high-speed machinery.
Which shaft material and size are required for the stated accuracy?
The stated scale factor and linearity apply to 42CrMo4 (AISI/SAE 4140) steel with a shaft diameter of at least 25 mm; other materials or smaller targets require recalibration or reduce the effective range.
Can the cable be shortened or extended during installation?
The stated performance applies to the complete matched probe–cable–converter chain, so the 8 m cable length should be preserved; modifying the cable changes the system calibration.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626