Sale!

EPRO PR6423/003-110 + CON021 Emerson Eddy Current Sensor System

The EPRO PR6423/003-110 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO machinery monitoring range: an 8 mm non-contact sensor probe and the CON021 signal converter that drives it. It is used on critical turbomachinery — steam, gas and hydro turbines, compressors, gearboxes, pumps and fans — to measure radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals without contacting the shaft.

Categories: , , , , SKU: PR6423/003-110 + CON021 Brand:

Description

Core Product Summary

The EPRO PR6423/003-110 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO machinery monitoring range: an 8 mm non-contact sensor probe and the CON021 signal converter that drives it. It is used on critical turbomachinery — steam, gas and hydro turbines, compressors, gearboxes, pumps and fans — to measure radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals without contacting the shaft.

Per its order code, this probe variant has an M10x1 case thread with a 55 mm case, an unarmored 5 m integral cable, no adapter plug, and a Lemo connector at the cable end. The converter energizes the probe and outputs the scaled gap and vibration signal over a 0 to 20 kHz (-3 dB) range with a rise time below 15 µs, feeding EPRO MMS monitoring modules. The sensor side provides a 2 mm linear range at 8 V/mm (±5% over 0 to 45 °C), IP66 protection, and operation up to +180 °C including its first metre of cable.

 

Key Technical Specifications

Parameter Value
System composition 8 mm eddy current sensor PR6423/003-110 + CON021 signal converter
Probe configuration M10x1 case thread, 55 mm case, unarmored, 5 m cable, no adapter plug, Lemo cable end
Linear measurement range 2 mm (80 mils)
Initial air gap 0.5 mm (20 mils)
Incremental scale factor (ISO) 8 V/mm (203.2 mV/mil) ± 5% at 0 to 45 °C
Deviation from best fit straight line (DSL) ± 0.025 mm (± 1 mil) at 0 to 45 °C
Minimum shaft diameter 25 mm (0.79 in)
Target material (standard) 42CrMo4 (AISI/SAE 4140) ferromagnetic steel
Sensor operating temperature (incl. 1 m cable) ‘-35 °C to +180 °C
Cable and connector temperature ‘-35 °C to +150 °C
Probe protection class IP66 per IEC 60529
Converter supply voltage ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V)
Converter frequency response (-3 dB) 0 to 20,000 Hz
Converter rise time < 15 µs
Converter operating temperature ‘-30 °C to +100 °C
Converter shock/vibration resistance 5 g at 60 Hz, 25 °C
Converter protection class IP20
Probe-to-converter connection Self-locking Lemo connector
Approvals (sensor) CE, ATEX, IECEx, CSA; intrinsic safety (ia) and non-sparking (nA)

 

Detailed Product Overview

The PR6423/003-110+CON021 is procured as a complete measurement channel, and that is the correct way to treat it: the 8 V/mm scale factor and ±0.025 mm linearity apply to the matched probe–cable–converter chain, not to the probe alone. The probe senses changes in the gap between its 8 mm tip and the conductive shaft surface; the CON021 supplies the high-frequency excitation, demodulates the resulting impedance variation, and delivers a DC voltage proportional to the average gap with the dynamic vibration component superimposed. A single channel therefore serves static position duties such as thrust or axial displacement as well as dynamic radial vibration measurement.

Mechanically, this variant combines the 55 mm case of the M10x1 family with a 5 m unarmored cable terminated in a Lemo connector. The 55 mm case suits deeper bearing housings and holder geometries that the shorter 25 mm or 35 mm versions cannot reach; when replacing an existing probe, the case length is one of the first checks, because a mismatch leaves the tip protruding incorrectly relative to the shaft surface. The 5 m cable is a deliberate part of the calibration: the electrical length of the probe–cable–converter chain is what the stated scale factor refers to, so cutting the cable, splicing in extra length, or swapping a converter from a chain built for a different cable length changes the system sensitivity. Where routing passes through mechanically exposed areas, protective conduit should be planned, since this variant is unarmored.

Electrically, the converter requires a negative supply from the monitoring rack — either -23 to -32 V for the -4 to -20 V output range or -21 to -32 V for the -2 to -18 V range — with the working gap voltage conventionally set near the midpoint of the linear range during commissioning. The 20 kHz bandwidth and sub-15 µs rise time preserve the dynamic content of high-speed machinery, including speed and keyphasor pulses sensed from a toothed wheel or shaft notch, which downstream monitoring modules use for phase reference and overspeed logic.

The accuracy conditions deserve attention at installation. The stated tolerances are defined against 42CrMo4 (AISI/SAE 4140) steel between 0 and 45 °C, with a minimum target diameter of 25 mm; different shaft alloys, residual magnetism in the shaft, or smaller targets shift the effective sensitivity and reduce usable linear range. The IP66 probe rating supports permanent dust and wash-down exposure at the machine, while the IP20 converter must be panel-mounted inside a cabinet. The sensor family’s hazardous-area approvals (ATEX, IECEx, CSA, with intrinsic safety ia and non-sparking nA modes of protection) permit classified-area installation when the converter and barrier arrangement follows the conditions stated in the approval documentation.

PR6423/003-110 + CON021

PR6423/003-110 + CON021

PR6423/003-110 + CON021

PR6423/003-110 + CON021

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Sensor–converter pairing PR6423/003-110 probe with CON021 eddy current signal converter The chain is calibrated as a matched probe–cable–converter set
Converter supply ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) Supplied by the monitoring system
Probe connection Lemo connector on the 5 m cable mates with the converter input Cable length is part of the chain calibration; do not modify
Converter mounting Panel mounting in a protected cabinet Converter is IP20
Monitoring system Output feeds EPRO MMS series monitoring modules Output range must match the monitor input channel configuration
Measured target 42CrMo4 (AISI/SAE 4140) steel, minimum shaft diameter 25 mm Other materials require recalibration of the chain
Mechanical fit M10x1 thread, 55 mm case Verify holder depth; sibling codes use 25/35/45 mm cases
Cable routing 5 m integral unarmored cable, Lemo end Add conduit where routing is mechanically exposed

 

Dimensions, Mounting & Connection Notes

  • Case thread: M10x1 with a 55 mm case length on this order code; standard M10 hardware uses SW 8 mm wrench flats on the case and SW 17 mm flats on the mounting nut side.
  • The probe is installed facing the shaft surface with a 0.5 mm (20 mils) initial air gap inside the 2 mm linear range, verified against the converter’s gap voltage during commissioning.
  • The integral cable is unarmored with a 2.8 mm diameter and a minimum bending radius of 25 mm; the Lemo connector at the cable end is 11.0 mm in diameter.
  • Sensor including 1 m of cable is rated -35 °C to +180 °C; the remaining cable and connector section is rated -35 °C to +150 °C.
  • The probe reaches IP66 per IEC 60529; the CON021 converter is IP20 and must be panel-mounted in a protected location.
  • Cable length tolerance is 0 to +10% of the nominal 5 m.

 

FAQ

What is the EPRO PR6423/003-110+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: an 8 mm non-contact sensor probe with a 5 m cable and Lemo termination, paired with the CON021 signal converter that drives it.

What is measured with this system?
The system measures radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals on rotating machinery such as steam, gas and hydro turbines, compressors, gearboxes, pumps and fans.

How is this probe variant configured?
It has an M10x1 case thread with a 55 mm case, an unarmored 5 m integral cable, no adapter plug, and a Lemo connector at the cable end.

What are the key measurement specifications?
The chain provides a 2 mm linear range, a 0.5 mm initial air gap, an 8 V/mm incremental scale factor ±5% over 0 to 45 °C, and a deviation from best fit straight line of ±0.025 mm over the same temperature range.

What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.

Why does cable length matter for this variant?
The stated 8 V/mm scale factor applies to the complete matched probe–cable–converter chain, so the 5 m cable length must be preserved; cutting or extending the cable changes the system calibration.

Which shaft material and size are required for the stated accuracy?
The stated scale factor and linearity apply to 42CrMo4 (AISI/SAE 4140) steel with a shaft diameter of at least 25 mm; other materials or smaller targets require recalibration or reduce the effective range.

Can this probe replace a different PR6423 cable-length variant directly?
The mechanical fit may look identical, but the chain calibration depends on the total cable length, so a variant with a different cable length should not be treated as a drop-in replacement without verifying the calibration of the complete chain.