EPRO PR6423/010-040+CON021 Emerson Eddy Current Sensor System

The EPRO PR6423/010-040 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO machinery monitoring range: an 8 mm non-contact sensor probe plus the CON021 signal converter that energizes it. It is used on critical turbomachinery — steam, gas and hydro turbines, compressors, gearboxes, pumps and fans — to measure radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals without touching the shaft.

Categories: , , , , SKU: PR6423/010-040+CON021 Brand:

Description

Core Product Summary

The EPRO PR6423/010-040 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO machinery monitoring range: an 8 mm non-contact sensor probe plus the CON021 signal converter that energizes it. It is used on critical turbomachinery — steam, gas and hydro turbines, compressors, gearboxes, pumps and fans — to measure radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals without touching the shaft.

This variant is built with an M10x1 case thread and a 25 mm case, and it is one of the mechanically protected long-range configurations of the family: the cable is armored, an adapter plug is provided after the first metre from the sensor, and the total cable length is 10 m, terminating in a Lemo connector. The converter supplies the probe excitation and outputs the scaled gap and vibration signal over 0 to 20 kHz (-3 dB) with a rise time below 15 µs for EPRO MMS monitoring modules. The sensor side provides a 2 mm linear range at 8 V/mm (±5% over 0 to 45 °C) and IP66 protection.

 

Key Technical Specifications

Parameter Value
System composition 8 mm eddy current sensor PR6423/010-040 + CON021 signal converter
Probe configuration M10x1 case thread, 25 mm case, armored cable, adapter plug, 10 m total cable, Lemo cable end
Linear measurement range 2 mm (80 mils)
Initial air gap 0.5 mm (20 mils)
Incremental scale factor (ISO) 8 V/mm (203.2 mV/mil) ± 5% at 0 to 45 °C
Deviation from best fit straight line (DSL) ± 0.025 mm (± 1 mil) at 0 to 45 °C
Minimum shaft diameter 25 mm (0.79 in)
Target material (standard) 42CrMo4 (AISI/SAE 4140) ferromagnetic steel
Sensor operating temperature (incl. 1 m cable) ‘-35 °C to +180 °C
Cable and connector temperature ‘-35 °C to +150 °C
Probe protection class IP66 per IEC 60529
Armored cable diameter / bend radius 6.0 mm / minimum 35 mm
Converter supply voltage ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V)
Converter frequency response (-3 dB) 0 to 20,000 Hz
Converter rise time < 15 µs
Converter operating temperature ‘-30 °C to +100 °C
Converter shock/vibration resistance 5 g at 60 Hz, 25 °C
Converter protection class IP20
Approvals (sensor) CE, ATEX, IECEx, CSA; intrinsic safety (ia) and non-sparking (nA)

 

Detailed Product Overview

The PR6423/010-040+CON021 is a complete measurement channel, and it should be evaluated as one: the 8 V/mm scale factor and ±0.025 mm linearity figures apply to the matched probe–cable–converter chain. The probe senses the gap between its 8 mm tip and the conductive shaft surface; the CON021 generates the high-frequency excitation, demodulates the impedance variation produced by shaft motion, and outputs a DC voltage proportional to the average gap with the dynamic vibration component superimposed. One channel therefore covers static position measurement (thrust, axial displacement) and dynamic radial vibration in the same installation.

What distinguishes this order code within the PR6423 family is the cable system. The 10 m total length is the longest standard configuration, intended for machines where the converter cabinet sits well away from the bearing — typical of large turbine halls with monitoring racks in a separate equipment room. Because the chain’s calibration is referenced to this total electrical length, the cable must not be shortened or extended on site; the 8 V/mm scale factor is valid only for the complete probe–cable–converter set as supplied. The adapter plug located after the first metre from the sensor separates the short probe-side cable from the long extension section, which simplifies probe replacement during overhauls: the armored extension run can stay in place while only the probe section is exchanged, provided the replacement matches the same cable-length configuration.

The armored cable answers the routing hazard of long runs. Over 10 m, the cable typically crosses walkways, cable trays and areas exposed to oil, steam, heat and mechanical impact; the flexible stainless steel armor protects the 6 mm cable from crushing, abrasion and cutting along the route. Its minimum bending radius is 35 mm, larger than the 25 mm of the unarmored cable, which must be respected at tray corners and gland entries. At the cabinet end, the Lemo connector mates with the converter’s self-locking input.

Electrically, the converter requires a negative supply from the monitoring rack — either -23 to -32 V for the -4 to -20 V output range or -21 to -32 V for the -2 to -18 V range — with the working gap voltage conventionally set near the middle of the linear range during commissioning. The 20 kHz bandwidth and sub-15 µs rise time preserve the dynamic content of high-speed machinery, including speed and keyphasor pulses.

As with the whole family, the accuracy conditions are target-dependent: the stated tolerances apply to 42CrMo4 (AISI/SAE 4140) steel between 0 and 45 °C, with a minimum shaft diameter of 25 mm. Other alloys, shaft magnetization, or smaller targets shift the effective sensitivity and reduce usable linear range. The IP66-rated probe supports permanent dust and wash-down exposure, while the IP20 converter must be panel-mounted in a protected cabinet. The sensor family’s hazardous-area approvals (ATEX, IECEx, CSA, with intrinsic safety ia and non-sparking nA modes of protection) permit classified-area installation when the converter and barrier arrangement follows the approval conditions.

PR6423/010-040+CON021

PR6423/010-040+CON021

PR6423/010-040+CON021

PR6423/010-040+CON021

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Sensor–converter pairing PR6423/010-040 probe with CON021 eddy current signal converter The chain is calibrated as a matched probe–cable–converter set
Converter supply ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) Supplied by the monitoring system
Probe connection Lemo connector at the cable end mates with the converter input Total 10 m cable length is part of the chain calibration
Adapter plug Provided after 1 m of cable from the sensor Separates probe-side cable from the armored extension section
Converter mounting Panel mounting in a protected cabinet Converter is IP20
Monitoring system Output feeds EPRO MMS series monitoring modules Output range must match the monitor input channel configuration
Measured target 42CrMo4 (AISI/SAE 4140) steel, minimum shaft diameter 25 mm Other materials require recalibration of the chain
Mechanical fit M10x1 thread, 25 mm case Standard short-case holder geometry
Cable routing Armored 10 m cable, minimum bending radius 35 mm Route to gland entries without sharp bends; do not modify length

 

Dimensions, Mounting & Connection Notes

  • Case thread: M10x1 with a 25 mm case length; standard M10 hardware uses SW 8 mm wrench flats on the case and SW 17 mm flats on the mounting nut side.
  • The probe is installed facing the shaft surface with a 0.5 mm (20 mils) initial air gap inside the 2 mm linear range, verified against the converter’s gap voltage during commissioning.
  • The armored cable has a 6.0 mm diameter and a minimum bending radius of 35 mm; an adapter plug is located after 1 m of cable from the sensor, and the cable end is a male Lemo connector 11.0 mm in diameter.
  • Sensor including 1 m of cable is rated -35 °C to +180 °C; the remaining cable and connector section is rated -35 °C to +150 °C.
  • The probe reaches IP66 per IEC 60529; the CON021 converter is IP20 and must be panel-mounted in a protected location.
  • Cable length tolerance is 0 to +10% of the nominal 10 m.

 

FAQ

What is the EPRO PR6423/010-040+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: an 8 mm non-contact sensor probe with an armored 10 m cable, adapter plug and Lemo termination, paired with the CON021 signal converter that drives it.

What is measured with this system?
The system measures radial and axial shaft dynamic displacement, shaft position, eccentricity and speed/keyphasor signals on rotating machinery such as steam, gas and hydro turbines, compressors, gearboxes, pumps and fans.

How is this probe variant configured?
It has an M10x1 case thread with a 25 mm case, an armored cable, an adapter plug after 1 m of cable from the sensor, a 10 m total cable length, and a Lemo connector at the cable end.

What are the key measurement specifications?
The chain provides a 2 mm linear range, a 0.5 mm initial air gap, an 8 V/mm incremental scale factor ±5% over 0 to 45 °C, and a deviation from best fit straight line of ±0.025 mm over the same temperature range.

What is the purpose of the adapter plug?
The adapter plug after the first metre of cable separates the probe-side cable from the extension section, so the probe can be replaced during maintenance without rerouting the long armored cable run, provided the replacement matches the same cable-length configuration.

What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.

Which shaft material and size are required for the stated accuracy?
The stated scale factor and linearity apply to 42CrMo4 (AISI/SAE 4140) steel with a shaft diameter of at least 25 mm; other materials or smaller targets require recalibration or reduce the effective range.

Can the 10 m cable be shortened or extended on site?
No. The stated performance applies to the complete matched probe–cable–converter chain, and the 10 m cable length is part of that calibration; modifying the cable changes the system scale factor.