Sale!

EPRO PR6424/003-030+CON021 Eddy Current Sensor System

The EPRO PR6424/003-030+CON021 is an eddy current measurement assembly combining a PR6424 16 mm non-contact sensor with a CON021 signal converter. Designed for rotating machinery monitoring, the system measures shaft displacement, position, eccentricity, and dynamic movement. These measurements support machinery condition monitoring by providing information about shaft motion relative to the sensor mounting point.

Categories: , , , , SKU: PR6424/003-030+CON021 Brand:

Description

Core Product Summary

The EPRO PR6424/003-030+CON021 is an eddy current measurement assembly combining a PR6424 16 mm non-contact sensor with a CON021 signal converter. Designed for rotating machinery monitoring, the system measures shaft displacement, position, eccentricity, and dynamic movement. These measurements support machinery condition monitoring by providing information about shaft motion relative to the sensor mounting point.

The PR6424 sensor operates using an eddy current measurement principle, while the CON021 conditions the sensor signal and provides an analog voltage output. The PR6424 series has a documented sensitivity of 4 V/mm and a static measurement range of ±2.0 mm. The CON021 converter supports a frequency response of 0–20 kHz at −3 dB and is designed for compatible PR642-series sensors. Correct selection requires matching the sensor variant, converter configuration, measurement range, cable termination, and installation requirements.

 

Key Technical Specifications

Parameter Specification
Manufacturer / brand EPRO / Emerson
Sensor model PR6424/003-030
Signal converter CON021
Sensor type 16 mm eddy current sensor
Measurement principle Non-contact eddy current
Measurement applications Shaft displacement, position, eccentricity, and dynamic movement
Sensor sensitivity 4 V/mm (101.6 mV/mil)
Sensor linearity ≤ ±1.5%
Static measurement range ±2.0 mm
Dynamic measurement range 0–1,000 μm
Nominal center air gap Approximately 2.7 mm
Target material Ferromagnetic steel; 42CrMo4 is the standard reference material
Sensor operating temperature −35 to +150°C
Converter operating temperature −30 to +100°C
Converter frequency response 0–20,000 Hz (−3 dB)
Converter rise time Less than 15 μs
Converter protection rating IP20
Converter supply voltage −23 to −32 V or −21 to −32 V, depending on output configuration
Converter output range −4 to −20 V or −2 to −18 V, depending on configuration
Sensor connection LEMO connector or open cable termination, depending on sensor variant
Converter output connection Screw terminals, maximum wire cross-section 1.5 mm²

 

System Compatibility & Integration Requirements

Item / Dependency Compatibility or Requirement Practical Note
Sensor family The CON021 documentation identifies PR6424 as a supported sensor family.
Converter configuration CON021 standard-range configuration Match the converter configuration to the sensor’s intended measurement range.
Measurement input Eddy current sensor The sensor and converter must be configured as a compatible measurement pair.
Power supply Negative DC supply, according to the selected output configuration Confirm the required supply voltage and output range against the installed converter.
Signal output Analog voltage Verify input compatibility with the connected machinery monitoring system.
Sensor connection Self-locking LEMO plug or applicable sensor termination Match the sensor cable termination to the converter connection.
Converter installation Screw mounting Allow for access to the terminals and sensor connector.
Hazardous-area installation Depends on the applicable sensor and converter approval configuration Confirm the complete assembly’s approval scope and any required current-limiting safety barrier.
PR6424/003-030+CON021

PR6424/003-030+CON021

Engineering Selection Highlights

  • Sensor family: PR6424 is a 16 mm eddy current sensor → confirm that the installed monitoring system is designed for the PR6424 series.
  • Measurement sensitivity: 4 V/mm → use the documented sensitivity when determining displacement scaling and interpreting the output signal.
  • Measurement range: The standard PR6424 sensor specification lists a static range of ±2.0 mm → confirm that this range covers the intended shaft-position measurement.
  • Frequency response: The CON021 provides a 0–20 kHz response at −3 dB → assess whether the converter’s frequency response meets the required dynamic measurement bandwidth.
  • Signal interface: The CON021 provides a voltage output → confirm the receiving monitor’s input range, polarity, and signal-conditioning requirements.
  • Installation environment: The converter is rated IP20 → install it in an enclosure appropriate for the cabinet environment.
  • Sensor-to-converter matching: The converter is designed for PR6424 sensors → verify the complete sensor order code and converter configuration before commissioning.

 

Dimensions, Mounting & Connection Notes

The CON021 signal converter uses a compact panel-mount housing with screw terminals for supply and output connections.

  • Mounting: Four M5 × 20 screws are specified for the converter.
  • Housing dimensions: The published drawing provides a nominal mounting footprint of approximately 50.8 mm × 50.8 mm, with an overall dimension of approximately 72 mm along the indicated housing axis.
  • Sensor connection: Self-locking LEMO plug.
  • Supply and output terminals: Screw terminals supporting wire cross-sections up to 1.5 mm².
  • Environmental conditions: The converter’s specified operating temperature range is −30 to +100°C, and its enclosure protection rating is IP20.

For the sensor, the PR6424 ordering code determines mechanical and cable configuration. Confirm the complete suffix and cable termination before selecting mounting hardware or planning the cable route.

 

Applications & System Role

The PR6424/003-030 + CON021 assembly serves as a measurement subsystem within rotating machinery instrumentation.

The sensor is installed in a fixed position relative to the monitored shaft. As the shaft moves, the gap between the sensor tip and the ferromagnetic target changes. The resulting electrical response is processed by the CON021 converter to produce a voltage signal representing the measured movement.

Typical engineering measurement tasks include:

  • Shaft displacement monitoring: Measuring shaft movement relative to the sensor mounting point.
  • Radial and axial movement measurement: Monitoring shaft motion along the applicable measurement axis.
  • Eccentricity measurement: Characterizing changes in shaft position relative to its reference.
  • Dynamic machinery monitoring: Providing a signal for monitoring shaft movement and vibration-related behavior.
  • Rotating equipment instrumentation: Supporting measurement arrangements for turbines, compressors, pumps, and fans.

The converter output must be connected to a monitoring input configured for the correct signal range and measurement scaling. Alarm and trip decisions, where required, are handled by the associated machinery protection or monitoring system rather than by the sensor alone.

 

Detailed Product Overview

Measurement principle and sensor function

The PR6424 uses eddy current sensing to measure the distance between its sensing face and a suitable conductive target. When positioned near a ferromagnetic steel shaft, changes in the sensor-to-target gap alter the electrical characteristics of the sensing circuit. This allows the sensor system to measure shaft position without requiring physical contact with the rotating surface.

The sensor’s sensitivity and linear measurement range are important when translating electrical output into engineering units. The documented PR6424 sensitivity of 4 V/mm provides a basis for displacement scaling, while the static and dynamic ranges describe different measurement conditions. The applicable range must be considered when configuring the monitoring channel.

Signal conversion and monitoring integration

The CON021 converts the sensor’s response into an analog voltage signal for use by compatible monitoring equipment. Its documented frequency response extends to 20 kHz at the −3 dB point, making the converter’s bandwidth an important consideration when selecting it for dynamic shaft measurements.

The selected output configuration determines the relevant supply-voltage and output-voltage ranges. Engineers should check these parameters against the receiving instrument’s input specification rather than assuming compatibility with a generic PLC analog input or a current-loop interface.

Installation and configuration

The sensor order code defines mechanical and cable-related characteristics. These details affect the available mounting arrangement, connector selection, and routing between the sensing location and converter. The probe must be positioned according to the applicable installation instructions, with the required target material and operating clearance taken into account.

The CON021 uses screw terminals for supply and signal output, while the sensor connects through a self-locking LEMO plug. Cabinet installation should also account for the converter’s IP20 rating and specified ambient temperature range.

Selection considerations

The complete measurement chain includes the sensor, converter, power supply, cabling, and receiving monitoring channel. Correct selection depends on the intended measurement range, signal polarity, dynamic bandwidth, mechanical installation, and environmental requirements. Where hazardous-area operation is required, approval must be assessed for the actual sensor-converter combination and installation arrangement.

 

FAQ

What is the EPRO PR6424/003-030 + CON021?

It is an eddy current measurement assembly comprising a PR6424 sensor and a CON021 signal converter for non-contact measurement of shaft movement.

What does the PR6424 sensor measure?

The PR6424 sensor is designed to measure radial and axial shaft displacement, position, eccentricity, and speed/key-related parameters in appropriate instrumentation configurations.

What is the sensitivity of the PR6424 sensor?

The documented sensitivity is 4 V/mm, with a specified linearity of no more than ±1.5%.

What is the frequency response of the CON021?

The CON021 has a documented frequency response of 0–20,000 Hz at the −3 dB point and a rise time below 15 μs.

What type of output does the CON021 provide?

The CON021 provides an analog voltage output. The applicable output range depends on the selected converter configuration.

Can the CON021 be used with other EPRO sensors?

The CON021 is documented for the PR6422, PR6423, PR6424, PR6425, and PR6426 sensor families, subject to the applicable measurement-range and configuration requirements.

What should be checked before ordering this assembly?

Confirm the full PR6424 order code, cable and connector configuration, required measurement range, CON021 output configuration, supply voltage, and compatibility with the receiving monitoring equipment.