The EPRO PR6424/010-040 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO range, built around the larger 16 mm sensor of the displacement family. It is designed for extremely critical turbomachinery — steam, gas, compressor and hydro machinery, blowers and fans — where it measures radial and axial shaft displacement, shaft position, eccentricity, thrust, differential expansion, valve position and air gaps without contacting the shaft.
Per its order code, this variant has an M18x1.5 sleeve thread with a 40 mm sleeve (52.5 mm total sensor length), a mechanically protected cable system — armored over its run, with an adapter plug separating the probe-side cable from the extension — a 10 m total cable length, and a Lemo connector at the end. Driven by the CON021 converter, the chain delivers a 4 V/mm (101.6 mV/mil) sensitivity with a ±2.0 mm static measuring range and 0 to 1000 µm dynamic range, meeting DIN 45670, ISO 10817-1 and API 670.
Key Technical Specifications
| Parameter | Value |
|---|---|
| System composition | 16 mm eddy current sensor PR6424/010-040 + CON021 signal converter |
| Probe configuration | M18x1.5 sleeve thread, armored cable, 40 mm sleeve / 52.5 mm total sensor length, adapter plug, 10 m cable, Lemo end |
| Sensitivity / linearity | 4 V/mm (101.6 mV/mil), linearity error within ±1.5% |
| Static measuring range | ±2.0 mm (0.079 in) |
| Dynamic measuring range | 0 to 1000 µm (0 to 0.039 in) |
| Air gap (center) | approx. 2.7 mm (0.11 in) |
| Long-term drift | < 0.3% |
| Target material (standard) | 42CrMo4 ferromagnetic steel |
| Minimum shaft diameter | ≥ 80 mm |
| Operating temperature range | ‘-35 °C to +150 °C (-31 to +302 °F) |
| Temperature error | < 4% per 100 K (API 670 compliant) |
| Pressure resistance of sensor tip | 10,000 hPa (145 psi) |
| Shock and vibration | 5 g at 60 Hz at 25 °C |
| Materials | Stainless steel case |
| Converter supply voltage | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) |
| Converter frequency response (-3 dB) | 0 to 20,000 Hz |
| Converter rise time | < 15 µs |
| Converter operating temperature | ‘-30 °C to +100 °C |
| Converter protection class | IP20 |
| Standards / approvals | DIN 45670, ISO 10817-1, API 670; rated for explosive areas, Eex ib IIC T6/T4 |
Detailed Product Overview
The PR6424/010-040+CON021 is a complete measurement channel for large rotating machinery, and the 16 mm sensor is what defines its role. The larger tip projects a wider electromagnetic field that requires a correspondingly large conductive target: the specified performance applies to shafts of at least 80 mm diameter, which places this probe on the rotors of large turbines, compressors and blowers rather than on small high-speed shafts. In return, the chain offers a generous working envelope — a ±2.0 mm static range around an approximately 2.7 mm center air gap, with 4 V/mm sensitivity — suited to position duties such as thrust, differential expansion and valve position as well as dynamic vibration measurement.
The CON021 converter completes the physics of the channel: it energizes the probe coil at high frequency, demodulates the impedance change produced by shaft motion, and outputs a DC voltage proportional to the average gap with the dynamic component superimposed. One channel therefore serves both static position and dynamic vibration monitoring. The converter draws a negative supply from the monitoring rack — either -23 to -32 V for the -4 to -20 V output range or -21 to -32 V for the -2 to -18 V range — and its 20 kHz bandwidth with sub-15 µs rise time preserves the dynamic signatures of high-speed machinery.
What distinguishes this order code within the 16 mm family is the cable system, which combines the two features that matter most for long, exposed routes. The cable is armored along its run, protecting the signal path from crushing, abrasion and impact across a 10 m span that will typically cross turbine-deck walkways and cable trays. The adapter plug separates the probe-side cable from the armored extension, so during overhauls the probe section can be exchanged while the long armored run stays in place — provided the replacement matches the same order code, because the 4 V/mm sensitivity applies to the complete probe–cable–converter chain and its total electrical length. The cable must therefore be routed as supplied and never shortened or extended.
The mechanical envelope is specific to the 16 mm family: the M18x1.5 sleeve thread requires holders, locknuts and drill-throughs sized for this series, so an installation prepared for the smaller M10x1 probes cannot accept this sensor. The 40 mm sleeve (52.5 mm total sensor length) is the shortest standard case of the family, appropriate where the bearing housing geometry offers limited insertion depth. Environmental limits are rated for the machine environment: -35 to +150 °C operation, temperature error below 4% per 100 K in line with API 670, and a sensor tip that withstands 10,000 hPa, permitting installation through pressurized bearing zones. The approval basis for hazardous areas is Eex ib IIC T6/T4 intrinsic safety, and the chain meets DIN 45670, ISO 10817-1 and API 670, the standards typically referenced in turbine supervisory instrumentation specifications.

PR6424/010-040+CON021
Dimensions, Mounting & Connection Notes
- Sleeve thread: M18x1.5 (3/4″-16 UNF is the alternative family thread), with a 40 mm sleeve and a 52.5 mm total sensor length on this order code.
- The probe is installed facing the shaft surface with the center air gap set at approximately 2.7 mm (0.11 in) during commissioning, inside the ±2.0 mm static range.
- The cable is armored over its run, with an adapter plug separating the probe-side cable from the extension section, a 10 m total length, and a Lemo connector at the end.
- Operating temperature range: -35 °C to +150 °C; the sensor tip withstands 10,000 hPa (145 psi) of pressure.
- Shock and vibration capability: 5 g at 60 Hz at 25 °C.
- The CON021 converter is IP20 and must be panel-mounted in a protected cabinet.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor–converter pairing | PR6424/010-040 probe with CON021 eddy current signal converter | Complete transducer system requires converter and cable selected as a matched chain |
| Converter supply | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) | Supplied by the monitoring system |
| Probe connection | Lemo connector at the 10 m cable end mates with the converter input | Total cable length is part of the chain calibration; do not modify |
| Adapter plug | Provided along the cable run | Separates the probe-side cable from the armored extension section |
| Mounting thread | M18x1.5 sleeve thread, 40 mm sleeve / 52.5 mm total length | Holders and drill-throughs are specific to the 16 mm family |
| Measured target | 42CrMo4 steel, shaft diameter at least 80 mm | Smaller shafts do not meet the specified performance |
| Standards compliance | DIN 45670, ISO 10817-1, API 670 | Relevant for TSI specification conformity |
| Hazardous area | Rated for explosive areas, Eex ib IIC T6/T4 | Installation must follow the intrinsic-safety conditions |
| Monitoring system | Output feeds EPRO MMS series monitoring modules | Output range must match the monitor input channel configuration |
FAQ
What is the EPRO PR6424/010-040+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: a 16 mm non-contact displacement sensor with an M18x1.5 thread, 40 mm sleeve, armored 10 m cable with adapter plug and Lemo termination, paired with the CON021 signal converter.
What is it used for?
It measures static and dynamic shaft displacement on large critical turbomachinery — axial and radial shaft position, eccentricity, shaft vibration, thrust, differential expansion, valve position and air gaps.
How is this probe variant configured?
It has an M18x1.5 sleeve thread with a 40 mm sleeve (52.5 mm total sensor length), an armored cable with an adapter plug, a 10 m total cable length, and a Lemo connector at the cable end.
What are its key specifications?
Sensitivity 4 V/mm (101.6 mV/mil) with linearity error within ±1.5%, static range ±2.0 mm, dynamic range 0 to 1000 µm, long-term drift below 0.3%, and operating range -35 °C to +150 °C.
What is the purpose of the adapter plug?
The adapter plug separates the probe-side cable from the armored extension section, so the probe can be replaced during maintenance without rerouting the long armored cable run, provided the replacement matches the same order code.
Which shaft size is required for the stated accuracy?
The stated performance applies to shafts of at least 80 mm diameter made of 42CrMo4 steel or a material with comparable properties; smaller shafts or different alloys require recalibration.
What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.
Can the 10 m cable be shortened or extended on site?
No. The stated sensitivity applies to the complete matched probe–cable–converter chain, and the 10 m cable length is part of that calibration; modifying the cable changes the system scale factor.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626