Description
Core Product Summary
The EPRO PR6426/010-110 +CON021/916-240 is an eddy current measurement assembly comprising a 32 mm non-contact displacement sensor and a CON021 signal converter. It is designed for rotating machinery applications requiring measurements of shaft displacement, radial and axial movement, position, and eccentricity. The probe detects changes in the gap between its sensing face and a ferromagnetic target, while the converter conditions the measurement signal for use by compatible monitoring equipment.
The CON021/916-240 is the PR6426 extended-range converter variant specified for a 24.0 mm measuring range, with a documented linearity error of ≤ ±3.5%. Correct selection requires matching the probe, converter configuration, target material, and receiving instrument. The complete assembly designation should be retained during procurement and maintenance to distinguish it from other PR6426 sensor and CON021 converter combinations.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | EPRO |
| Sensor model | PR6426/010-110 |
| Signal converter | CON021/916-240 |
| Product type | Eddy current displacement sensor and signal converter |
| Sensor diameter class | 32 mm |
| Measurement principle | Non-contact eddy current sensing |
| Sensor sensitivity | 2 V/mm |
| Sensor static measuring range | ±4.0 mm |
| Nominal center air gap | Approximately 5.5 mm |
| Long-term drift | Less than 0.3% |
| Target material | Ferromagnetic steel |
| Minimum shaft diameter | 200 mm |
| Sensor operating temperature | −35 to +180°C |
| Short-term sensor temperature | 200°C for less than 4 hours |
| Converter extended measuring range | 24.0 mm |
| Converter linearity error for the selected range | ≤ ±3.5% |
| Converter frequency response | 0–20 kHz at −3 dB |
| Converter rise time | Less than 15 μs |
| Converter operating temperature | −30 to +100°C |
| Converter protection rating | IP20 |
| Converter supply voltage for −4 to −20 V output | −23 to −32 V DC |
Engineering Selection Highlights
- 32 mm sensor configuration: The PR6426/010-110 belongs to the 32 mm eddy current sensor family. Check the mounting arrangement and shaft clearance before installation.
- Extended measuring range: The CON021/916-240 is specified for a 24.0 mm extended range, with a linearity error of ≤ ±3.5%. Confirm that this range matches the intended measurement channel.
- Sensor and converter pairing: The PR6426 probe and CON021 converter must be selected as a compatible measurement chain, with the correct range configuration.
- Target material: The documented target material is ferromagnetic steel. Shaft material affects calibration and measurement characteristics.
- Mechanical clearance: The documented minimum shaft diameter is 200 mm. Confirm the actual shaft geometry and available probe mounting space.
- Temperature separation: The probe and converter have different operating-temperature limits. Their mounting locations must be evaluated independently.
- Signal interface: Confirm the converter’s output configuration, supply voltage, and receiving instrument input requirements before commissioning.

PR6426010-110+C0N021916-240

PR6426010-110+C0N021916-240
System Compatibility & Integration Requirements
| Item | Requirement | Practical Note |
|---|---|---|
| Sensor | EPRO PR6426/010-110 | Retain the full probe ordering code when replacing the installed component. |
| Signal converter | CON021/916-240 | The /916-240 suffix identifies the 24.0 mm extended-range configuration. |
| Target | Ferromagnetic steel | Target material and calibration must correspond to the measurement setup. |
| Monitoring instrument | Compatible voltage-input equipment | Confirm input range, signal scaling, and required measurement bandwidth. |
| Power supply | Negative DC supply | The required voltage depends on the selected converter output configuration. |
| Mounting | Rigid, vibration-free probe support | Probe movement can affect the displacement measurement. |
| Environmental installation | Separate probe and converter conditions | Observe the specified temperature and enclosure limits for each component. |
Dimensions, Mounting & Connection Notes
The PR6426/010-110 is a 32 mm eddy current sensor designed for installation in a suitable mounting arrangement. The sensor must be positioned to maintain the required measurement gap and sufficient clearance from the shaft and other ferromagnetic material.
The probe’s documented minimum shaft diameter is 200 mm. The sensor mounting structure should remain rigid during machine operation to avoid introducing unwanted motion into the measurement.
The CON021 converter is a separate signal-conditioning component. Its enclosure protection rating and operating-temperature range should be considered when choosing a mounting location. Supply wiring, output wiring, connector configuration, and cable routing must follow the requirements of the actual converter and sensor assembly.
Applications & System Role
The EPRO PR6426/010-110 + CON021/916-240 assembly provides the sensing and signal-conditioning functions within a rotating machinery monitoring channel. The eddy current probe measures changes in the distance between its sensing face and a conductive target. The converter processes the probe response and supplies an output for compatible monitoring equipment.
Potential measurement functions include:
- Radial shaft displacement: Detecting changes in shaft position relative to the probe.
- Axial displacement: Measuring shaft movement along its axis when the probe is installed in the appropriate orientation.
- Shaft vibration: Providing a dynamic displacement signal for a suitable monitoring channel.
- Position and eccentricity: Monitoring changes in the relative position of the shaft and sensor.
- Rotating machinery condition monitoring: Supplying measurement data to equipment designed to interpret the converter output.
The CON021 converter family is intended for critical rotating machinery applications, including turbines, compressors, pumps, and fans. The exact function depends on the probe arrangement, converter configuration, target geometry, and capabilities of the receiving monitoring system.
For replacement projects, the full assembly designation matters. A probe with the same family number may be configured for a different measuring range or installation arrangement. The converter’s /916-240 range designation should therefore be retained when identifying the required assembly.
Detailed Product Overview
Sensor construction and measurement function
The PR6426/010-110 is part of EPRO’s 32 mm eddy current sensor family. Its non-contact sensing principle allows displacement to be measured without mechanical contact between the probe and the rotating shaft. The probe responds to changes in the gap between its sensing face and the target, making it suitable for static position measurements and dynamic displacement monitoring when paired with the appropriate signal converter.
The documented sensor sensitivity is 2 V/mm, and its static measuring range is ±4.0 mm. These values describe the sensor’s specified measurement characteristics and should not be confused with the 24.0 mm extended measuring-range designation of the selected converter variant.
Signal conversion and range selection
The CON021/916-240 processes the sensor signal and provides an electrical output for compatible monitoring equipment. Its specified 24.0 mm extended range has a linearity error of ≤ ±3.5%. Range selection is therefore a key part of determining whether the assembly meets the measurement requirements of a particular machine or monitoring channel.
The CON021 family also supports different output configurations. The selected output and its supply-voltage requirement must match the intended instrumentation. Incorrect signal scaling or a mismatched converter configuration can lead to an unsuitable measurement range or incorrect interpretation of shaft movement.
Installation and environmental considerations
The PR6426/010-110 is specified for a sensor operating temperature range of −35 to +180°C, with short-term operation at 200°C for less than four hours. The converter has a separate operating-temperature range of −30 to +100°C. These limits apply to different components and should be considered separately when planning installation.
A rigid probe mounting arrangement, suitable shaft clearance, correct measurement gap, and appropriate target material are important to the measurement setup. The probe and converter should be treated as a matched assembly, with the complete ordering codes recorded for maintenance and procurement.
Procurement and replacement identification
When sourcing this assembly, identify both components explicitly: PR6426/010-110 and CON021/916-240. The converter range suffix is important because the CON021 family includes multiple configurations with different measurement ranges and linearity specifications.
Before returning a replacement measurement channel to service, confirm the converter configuration, supply voltage, output scaling, cable and connector arrangement, and monitoring-instrument settings.
FAQ
What is the EPRO PR6426/010-110 + CON021/916-240?
It is an eddy current sensor and signal-converter assembly for non-contact displacement measurement in rotating machinery monitoring systems.
What is the function of the PR6426/010-110?
The PR6426/010-110 measures changes in the gap between the probe and a metallic target. It can provide measurement signals for shaft displacement, position, eccentricity, and vibration monitoring when used with a compatible converter.
What does CON021/916-240 mean?
The designation identifies a CON021 extended-range converter configuration for the PR6426 sensor family, with a specified measuring range of 24.0 mm and a linearity error of ≤ ±3.5%.
What is the sensor’s sensitivity?
The documented sensitivity for the PR6426/010-110 is 2 V/mm.
What are the operating temperature limits?
The sensor is specified for −35 to +180°C, with short-term operation at 200°C for less than four hours. The CON021 converter is specified for −30 to +100°C.
Which target material is required?
The documented target material is ferromagnetic steel. Target material should be considered when assessing calibration and measurement suitability.
What should be checked before ordering a replacement?
Confirm the full sensor and converter ordering codes, measuring-range configuration, target material, mounting arrangement, cable and connector details, supply voltage, output configuration, and receiving instrument requirements. These details help establish whether the assembly matches the installed measurement channel.