Description
Core Product Summary
The EPRO PR6426/010-140 with CON021 is a matched eddy current measuring chain from Emerson’s EPRO range, built around the 32 mm large-target sensor of the displacement family. It is designed for extremely critical turbomachinery — steam, gas, compressor and hydro machinery, blowers and fans — where it measures static and dynamic shaft displacement without contacting the rotor: axial and radial shaft position, differential expansion, eccentricity, thrust, valve position and air gaps. Its 2 V/mm sensitivity over a wide span suits large-range expansion and position duties rather than small-amplitude radial vibration.
Per its order code, this variant mounts via the family’s fixed 80 × 40 mm mounting plate instead of a sleeve thread, and it is the mechanically protected long-run configuration: the cable is armored, runs continuously without an adapter plug, spans 10 m in total, and terminates in a Lemo connector. Driven by the CON021 converter, the chain’s linearity stays within ±1.5%, and it meets DIN 45670, ISO 10817-1 and API 670, with Eex ib IIC T6/T4 approval for explosive areas.
Key Technical Specifications
| Parameter | Value |
|---|---|
| System composition | 32 mm eddy current sensor PR6426/010-140 + CON021 signal converter |
| Probe configuration | No sleeve thread; 80 × 40 mm mounting plate, armored cable, no adapter plug, 10 m total cable, Lemo end |
| Sensitivity | 2 V/mm (50.8 mV/mil) |
| Linearity | Within ±1.5% |
| Mounting method | Mounting plate (80 × 40 mm), not a threaded sleeve |
| Target material (standard) | 42CrMo4 ferromagnetic steel |
| Converter supply voltage | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) |
| Converter frequency response (-3 dB) | 0 to 20,000 Hz |
| Converter rise time | < 15 µs |
| Converter operating temperature | ‘-30 °C to +100 °C |
| Converter protection class | IP20 |
| Standards | DIN 45670, ISO 10817-1, API 670 |
| Hazardous-area rating | Eex ib IIC T6/T4 |
| Probe-to-converter connection | Lemo connector at the armored cable end |
Detailed Product Overview
The PR6426/010-140+CON021 is the large-target, long-run configuration of the EPRO displacement family, and both descriptors shape its use. The 32 mm tip projects a wide electromagnetic field that requires a large conductive target, placing this sensor on turbine rotors and casing-relative measurement points where the span, not fine resolution, drives selection. With 2 V/mm sensitivity and linearity within ±1.5%, the chain is applied to differential expansion on turbine trains, thrust position on large rotors, valve position and air-gap measurement — duties involving large positional excursions for which the smaller 8 V/mm probes would saturate.
The CON021 converter completes the channel: it energizes the probe coil at high frequency, demodulates the impedance change produced by target motion, and outputs a DC voltage proportional to the average gap with the dynamic component superimposed. The converter draws a negative supply from the monitoring rack — either -23 to -32 V for the -4 to -20 V output range or -21 to -32 V for the -2 to -18 V range — and its 20 kHz bandwidth with sub-15 µs rise time preserves dynamic content even though this sensor’s duties are dominated by slower, larger movements.
This order code combines the family’s mounting-plate body with its most protected cable system. The probe fixes through an 80 × 40 mm mounting plate bolted to a machined casing surface or bracket — a rigid, low-hysteresis mounting appropriate for large-gap position measurement, and one whose footprint cannot be adapted from a threaded holder on site. The cable is armored over its full 10 m run, protecting the signal path from crushing, abrasion and impact across a span that will typically cross turbine-deck walkways and trays. There is no adapter plug: the armored cable runs continuously from sensor to Lemo connector, which simplifies the electrical path but means the entire run must be pulled if the probe is replaced with a different configuration — so the complete order code should be matched exactly at replacement time.
As across the family, the calibration belongs to the whole chain: the 2 V/mm sensitivity and ±1.5% linearity apply to the matched probe–cable–converter set, and the 10 m cable length is part of that calibration. Shortening, splicing or extending the cable invalidates the stated performance. The chain meets DIN 45670, ISO 10817-1 and API 670 — the standards typically referenced in turbine supervisory instrumentation specifications — and it carries the Eex ib IIC T6/T4 intrinsic-safety rating for explosive areas, subject to the converter and barrier arrangement following the approval conditions. The calibration basis is 42CrMo4 steel; other target alloys or magnetized surfaces shift the effective sensitivity and require recalibration of the converter chain.

PR6426/010-140+CON021
Dimensions, Mounting & Connection Notes
- The probe has no sleeve thread; it is installed via an 80 × 40 mm mounting plate fixed to a machined surface or bracket on the machine casing.
- The cable is armored over its full 10 m length, without an adapter plug, terminating in a Lemo connector at the converter end.
- The probe is installed facing the conductive target surface, with the working gap set inside the linear range and verified against the converter’s gap voltage during commissioning.
- The CON021 converter is IP20 and must be panel-mounted in a protected cabinet.
- Cable length tolerance should be preserved; the sensitivity applies to the complete matched chain.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Sensor–converter pairing | PR6426/010-140 probe with CON021 eddy current signal converter (range-matched version for the 32 mm sensor) | Complete transducer system requires converter and cable selected as a matched chain |
| Converter supply | ‘-23 V to -32 V (output -4 V to -20 V) or -21 V to -32 V (output -2 V to -18 V) | Supplied by the monitoring system |
| Probe connection | Lemo connector at the 10 m armored cable end mates with the converter input | Cable length is part of the chain calibration; do not modify |
| Mounting method | 80 × 40 mm mounting plate; no sleeve thread | Installation footprint must match the plate pattern; threaded holders cannot be adapted |
| Measured target | 42CrMo4 steel calibration basis | Other target materials require converter recalibration |
| Standards compliance | DIN 45670, ISO 10817-1, API 670 | Relevant for TSI specification conformity |
| Hazardous area | Rated for explosive areas, Eex ib IIC T6/T4 | Installation must follow the intrinsic-safety conditions |
| Monitoring system | Output feeds EPRO MMS series monitoring modules | Output range must match the monitor input channel configuration |
| Cable routing | Armored 10 m cable, continuous without adapter plug | Route to gland entries without sharp bends; do not modify length |
FAQ
What is the EPRO PR6426/010-140+CON021?
It is a complete eddy current measuring chain from Emerson’s EPRO range: a 32 mm large-target displacement sensor with a mounting-plate body and a continuous armored 10 m cable with Lemo termination, paired with the CON021 signal converter.
What is it used for?
It measures static and dynamic shaft displacement on large critical turbomachinery — axial and radial shaft position, differential expansion, eccentricity, thrust, valve position and air gaps.
How is this probe variant configured?
It mounts via an 80 × 40 mm plate instead of a thread, and its cable is armored, runs 10 m in total without an adapter plug, and ends in a Lemo connector.
What are its key specifications?
Sensitivity 2 V/mm (50.8 mV/mil) with linearity within ±1.5%, DIN 45670 / ISO 10817-1 / API 670 compliance, and an Eex ib IIC T6/T4 rating for explosive areas.
What does the lack of an adapter plug mean for maintenance?
The armored cable runs continuously from sensor to Lemo connector with no mid-run separation point, so a probe replacement involves the full cable run, and the replacement should match this complete order code.
What power supply does the CON021 require?
The converter operates from -23 V to -32 V with a -4 V to -20 V output, or from -21 V to -32 V with a -2 V to -18 V output, supplied by the connected monitoring system.
Can the 10 m armored cable be shortened or extended on site?
No. The stated sensitivity applies to the complete matched probe–cable–converter chain, and the 10 m cable length is part of that calibration; modifying the cable changes the system scale factor.
Which target material is the calibration based on?
The standard calibration basis is 42CrMo4 steel; shafts of other alloys or magnetized surfaces require recalibration of the converter chain.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626