Core Product Summary (Brand / Model / Key Attributes)
The GE IC698ETM001 is a rack-mounted Ethernet interface module designed for the PACSystems RX7i programmable automation controller platform. Installed in an RX7i VME64 backplane slot, it adds dedicated TCP/IP Ethernet connectivity to RX7i control systems for peer-to-peer data exchange, supervisory SCADA/HMI communication, and controller programming.
Equipped with a 200 MHz Ethernet processor and an embedded internal network switch, the IC698ETM001 provides two auto-negotiating 10Base-T/100Base-TX RJ45 ports that share a single configured IP address. It supports Ethernet Global Data (EGD), SRTP server/client services (firmware-dependent), and Modbus TCP communications, alongside a front-panel RS-232 Station Manager port for local diagnostics and configuration. The module draws +5 VDC from the RX7i rack power supply and is configured through Proficy Machine Edition (PAC Machine Edition).
Key Technical Specifications
| Parameter | Verified Specification |
| Manufacturer / Brand | GE (PACSystems) |
| Model / Order Number | IC698ETM001 |
| Product Series | PACSystems RX7i |
| Product Type | Ethernet Interface Module |
| Backplane Bus Interface | PACSystems RX7i VME64 backplane |
| Ethernet Processor Speed | 200 MHz |
| Ethernet Ports | 2 × RJ45 (10Base-T / 100Base-TX), shielded, auto-sensing speed, duplex, and crossover |
| Internal Network Architecture | Integrated 2-port switch sharing one IP address |
| Supported Ethernet Protocols | Ethernet Global Data (EGD), SRTP, Modbus TCP (firmware-dependent) |
| Station Manager Serial Port | 1 × RS-232 DCE (9-pin female D-sub), 1200 to 115,200 bps |
| Backplane Power Requirement | +5 VDC from RX7i power supply; 1.2 A typical, 1.5 A maximum |
| Operating Temperature | 0 °C to +60 °C (32 °F to 140 °F) |
| Front Diagnostic LEDs | MODULE OK, LAN ONLINE, STATUS, 100 / LINK (Port 1 & Port 2) |
| Configuration Software | Proficy Machine Edition (PAC Machine Edition) |
Detailed Product Overview
While PACSystems RX7i CPUs include an embedded Ethernet interface, complex control architectures frequently require network segmentation between plant supervisory networks, peer-to-peer controller links, and field-level Ethernet devices. The GE IC698ETM001 expands an RX7i rack with an independent, dedicated Ethernet interface powered by a 200 MHz communications processor.
Both front-panel RJ45 ports connect to an embedded two-port switch and operate under a single IP address. Auto-negotiation automatically detects 10 Mbps or 100 Mbps line speeds, full- or half-duplex operation, and MDI/MDI-X crossover cabling, allowing direct connection to industrial switches or daisy-chained nodes without external transceivers. Because both ports share one internal switch and IP address, network cabling must form a tree or linear topology rather than a closed loop to prevent packet duplication and broadcast storms.
In operation, the module executes deterministic peer-to-peer exchanges via Ethernet Global Data (EGD) and handles client/server requests over SRTP and Modbus TCP (depending on hardware/firmware revision). Firmware is stored in onboard flash memory and can be updated in the field, while Redundant IP addressing is supported in firmware version 2.00 and later for Hot Standby CPU Redundancy architectures. Local troubleshooting and TCP/IP stack monitoring are accessible through the front 9-pin RS-232 Station Manager interface.

IC698ETM001
Engineering Selection Highlights
- Dedicated RX7i network expansion → Adds an independent Ethernet interface to an RX7i VME64 rack when the CPU’s embedded Ethernet port is already dedicated to another network segment.
- Integrated 2-port 10/100 Mbps switch (1 IP address) → Enables linear daisy-chaining of Ethernet nodes directly at the rack without an external unmanaged switch, provided no network loop is formed.
- EGD, SRTP, and Modbus TCP support → Facilitates deterministic controller-to-controller data exchange (EGD) and HMI/SCADA connectivity within PACSystems networks.
- Redundant IP capability (Firmware 2.00+) → Supports IP failover when paired with PACSystems RX7i Hot Standby CPU Redundancy configurations.
- Dedicated RS-232 Station Manager port → Provides direct out-of-band serial access for IP assignment, exception log inspection, and network diagnostics if Ethernet connectivity is unavailable.
- 1.5 A max @ +5 VDC power draw → Must be accounted for in the RX7i rack’s +5 VDC power budget alongside the CPU and other VME modules.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Controller Platform | GE PACSystems RX7i Rack / VME64 Backplane | Designed exclusively for PACSystems RX7i racks; Series 90-70 LAN modules (such as IC697CMM742) are not interchangeable. |
| Rack Power Supply | RX7i System Power Supply (+5 VDC rail) | Verify total rack +5 VDC load accommodates the module’s 1.2 A typical / 1.5 A maximum current draw. |
| Engineering Software | Proficy Machine Edition (PAC Machine Edition) | Required to configure IP parameters, EGD exchanges, and hardware settings. |
| Network Topology | Tree or linear Ethernet topology (10Base-T / 100Base-TX) | Do not connect both RJ45 ports directly or indirectly to the same switch/device, as the ports are internally switched without spanning-tree loop protection. |
| Firmware / Revision Alignment | IC698ETM001 hardware/firmware suffixes (e.g., -AA through -FU) | Redundant IP addressing requires firmware version 2.00 or higher; verify firmware revision when matching existing spare configurations. |
Dimensions, Mounting & Connection Notes
- Rack Installation: Installs into an available slot in a PACSystems RX7i VME64 chassis; align the module card edges with the top and bottom chassis guides, seat the backplane connectors firmly, and fasten the top and bottom retaining screws.
- Ethernet Connections: Two front-panel 8-pin female shielded RJ45 jacks supporting CAT5 (or higher) shielded or unshielded twisted-pair cabling at 10/100 Mbps.
- Serial Station Manager Port: Front-panel 9-pin female D-sub RS-232 DCE connector operating from 1200 to 115,200 bps for terminal-based Station Manager diagnostics.
- IP Address Configuration: A default IP address of
0.0.0.0causes the module to broadcast BOOTP requests at power-up; assign a valid static IP address via Proficy Machine Edition or the SetIP utility before connecting to a production network. - Thermal Limits: Maintain ambient enclosure temperature within 0 °C to +60 °C and ensure adequate chassis airflow per RX7i rack cooling guidelines.
FAQ
What is the GE IC698ETM001? The GE IC698ETM001 is a dual-port 10/100 Mbps Ethernet interface module for the PACSystems RX7i programmable automation controller platform.
Do the two RJ45 ports on the IC698ETM001 have separate IP addresses? No. Both RJ45 ports connect to an embedded internal switch and share a single configured IP address.
Can both Ethernet ports be connected to the same network switch for redundancy? No. Because the two ports are internally switched, connecting both ports to the same switch or creating a closed ring will cause packet duplication and network overload.
Which communication protocols does the IC698ETM001 support? It supports Ethernet Global Data (EGD), SRTP, and Modbus TCP (depending on the installed firmware revision), as well as standard TCP/IP programming and configuration services.
What is the 9-pin D-sub port on the front of the module used for? The 9-pin female RS-232 DCE port is the Station Manager interface, used for local serial diagnostics, viewing exception logs, and checking network parameters.
How much power does the IC698ETM001 draw from the RX7i backplane? It operates from the rack’s +5 VDC supply, drawing 1.2 A typically and up to 1.5 A maximum.
Verification & Troubleshooting Notes
- Startup & Module Health LEDs: Confirm that
MODULE OKilluminates solid green after power-up; ifMODULE OKis off or blinking an error code, inspect the PLC Fault Table in Proficy Machine Edition or connect to the Station Manager serial port. - Ethernet Link & Speed Verification: Check the individual port
LINKand100LEDs when CAT5 cables are connected; an unlitLINKLED indicates a physical cable fault, disabled switch port, or missing link partner. - Network Loop Check: If severe network congestion or packet flooding occurs immediately after connecting the module, verify that Port 1 and Port 2 are not wired into the same switch or looped back together.
- IP & Duplicate Address Checks: If the module cannot be reached over TCP/IP, verify its IP address, subnet mask, and gateway via Proficy Machine Edition or the RS-232 Station Manager port (1200–115,200 bps), noting that duplicate IP conflicts on the network can disrupt communication without always logging a PLC fault entry.
- Safety Precaution: Always power down the RX7i chassis before inserting or removing the IC698ETM001 module from the VME64 backplane.