The HIMA F8627X is an Ethernet communication module for HIMA H41q/H51q safety systems. It provides a 100Base-T RJ45 interface and supports SafeEthernet communication between H41q/H51q systems in mono or redundant configurations.
The F8627X also supports OPC DA and OPC A&E through the HIMA OPC server, Modbus TCP slave communication, and ELOP II programming over Ethernet from ELOP II version 4.1. It is a 19-inch module, 3 HU high by 4 WU wide, designed for use with the F8650X/F8652X safety CPUs and F8651X/F8653X non-safe CPUs.
Key Technical Specifications
| Parameter | Verified information |
|---|---|
| Manufacturer | HIMA Paul Hildebrandt GmbH + Co KG |
| Exact model | F8627X |
| Order number | 98 4862765 |
| Product type | Communication module |
| System family | HIMA H41q / H51q |
| Primary function | Ethernet communication between the central module and external systems |
| Ethernet interface | 100Base-T |
| Ethernet connector | RJ45 |
| Safety communication | SafeEthernet, mono or redundant configuration |
| Standard communication | OPC DA via HIMA OPC server |
| Additional protocols | OPC A&E, Modbus TCP slave |
| Programming interface | ELOP II via Ethernet, from ELOP II version 4.1 |
| Module format | 19-inch module, 3 HU × 4 WU |
| Module dimensions | 3 × 44.45 mm high × 4 × 5.08 mm wide |
| Compatible safety CPUs | F8650X / F8652X |
| Compatible non-safe CPUs | F8651X / F8653X |
| Operating-system dependency | Additional functions supported with OS version 4.x or higher |
| Reference documentation | HIMA F8627X/F8628X product documentation |
Engineering Selection Highlights
- H41q/H51q Ethernet interface: The F8627X is a communication module for HIMA H41q/H51q systems, providing the Ethernet link between the central module and external communication partners.
- SafeEthernet support: It supports SafeEthernet in mono or redundant configurations, making it relevant where safety-related communication between H41q/H51q systems is required.
- OPC and Modbus TCP integration: The module supports OPC DA and OPC A&E through the HIMA OPC server, along with Modbus TCP slave communication.
- Ethernet programming capability: ELOP II programming over Ethernet is supported from ELOP II version 4.1, allowing engineering access through the Ethernet interface.
- CPU compatibility: The module is used with F8650X/F8652X safety CPUs and F8651X/F8653X non-safe CPUs.
- Operating-system dependency: The additional functions of the X version are supported with operating-system version 4.x or higher.
- Exact-suffix matching: The complete designation, F8627X, should be matched against the installed module and system documentation, since F8627 and F8628 modules are related but distinct.

F8627X
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Control platform | HIMA H41q / H51q | The F8627X is a communication module for these systems. |
| Safety CPUs | F8650X / F8652X | Compatible safety CPU modules for the F8627X. |
| Non-safe CPUs | F8651X / F8653X | Compatible non-safe CPU modules for the F8627X. |
| Ethernet interface | 100Base-T, RJ45 | Provides the Ethernet communication path. |
| Safety communication | SafeEthernet, mono or redundant | Supports safety-related communication between H41q/H51q systems. |
| Standard communication | OPC DA, OPC A&E, Modbus TCP slave | Defines the standard protocol support available through the module. |
| Programming interface | ELOP II via Ethernet, from version 4.1 | Enables Ethernet-based programming access. |
| Operating system | OS version 4.x or higher | Required for the additional functions of the X version. |
| Module format | 19-inch, 3 HU × 4 WU | Defines the physical module format for the H41q/H51q rack. |
Dimensions, Mounting & Connection Notes
The F8627X is a 19-inch module for HIMA H41q/H51q systems, with a height of 3 HU (3 × 44.45 mm) and a width of 4 WU (4 × 5.08 mm). It is designed for installation in the H41q/H51q rack architecture.
The module provides a 100Base-T Ethernet interface with an RJ45 connector. Its communication function is to link the central module with external Ethernet-based systems, supporting SafeEthernet, OPC, Modbus TCP, and ELOP II programming over Ethernet.
Detailed Product Overview
The HIMA F8627X is an Ethernet communication module for HIMA H41q/H51q safety systems. It provides a 100Base-T RJ45 interface and supports SafeEthernet communication between H41q/H51q systems in mono or redundant configurations.
The module’s communication function is to link the central module with external Ethernet-based systems. It supports OPC DA and OPC A&E through the HIMA OPC server, Modbus TCP slave communication, and ELOP II programming over Ethernet from ELOP II version 4.1. These protocol capabilities define the module’s role in both safety-related and standard data-exchange applications.
The F8627X is a 19-inch module, 3 HU high by 4 WU wide, designed for use with the F8650X/F8652X safety CPUs and F8651X/F8653X non-safe CPUs. Its physical format and CPU compatibility define its place within the H41q/H51q rack architecture.
The X version of the F8627X adds functionality beyond the base F8627 module. The additional functions are supported with operating-system version 4.x or higher, and the module’s protocol support reflects this expanded capability. The existing F8627 and F8628 modules remain available in the product portfolio, making exact-suffix matching important during replacement or procurement.
For integration planning, the F8627X should be evaluated in the context of the complete H41q/H51q system configuration. Its Ethernet communication function is meaningful only when integrated with the associated HIMA control architecture, and the applicable system-level documentation should be used to confirm the module’s role, installation requirements, and interface relationships.
Applications & System Role
Within a HIMA H41q/H51q safety-system architecture, the F8627X performs the Ethernet communication role between the central module and external systems. Its function is to provide the communication path through which safety-related and standard data exchange occurs.
The module supports SafeEthernet for safety-related communication between H41q/H51q systems, as well as OPC DA, OPC A&E, and Modbus TCP slave for standard data exchange. It also supports ELOP II programming over Ethernet, making it relevant to systems where engineering access and protocol integration are required through the Ethernet interface.
FAQ
What is the HIMA F8627X?
It is a HIMA Ethernet communication module for H41q/H51q safety systems, providing a 100Base-T RJ45 interface.
What protocols does the F8627X support?
It supports SafeEthernet, OPC DA, OPC A&E, Modbus TCP slave, and ELOP II programming over Ethernet.
Which CPUs is the F8627X compatible with?
It is compatible with F8650X/F8652X safety CPUs and F8651X/F8653X non-safe CPUs.
What is the module format of the F8627X?
It is a 19-inch module, 3 HU high by 4 WU wide, for HIMA H41q/H51q systems.
What operating-system version is required for the X-version functions?
The additional functions of the F8627X are supported with operating-system version 4.x or higher.
Can the F8627X be used for redundant SafeEthernet communication?
Yes. It supports SafeEthernet in both mono and redundant configurations.
Why is the full model suffix important?
The complete designation, F8627X, identifies the exact module variant and should be matched against the installed module and system documentation during replacement or procurement.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626