Sale!

HIMA X-FAN 18 03 HIMax System Fan Module

Category Specification
Product type HIMax system fan module
Model X-FAN 18 03
Part number 993201813
Number of fans 4
Intended base plate HIMax X-Base Plate 18 01
Supply voltage 24 VDC
Current consumption 0.9 A
Monitoring signal Yes
Mounting method Slide-in module for HIMax base-plate arrangement
Assembly type Complete four-fan assembly
Function Forced-air cooling for HIMax modules and base plate
Categories: , , , , SKU: X-FAN 18 03 Brand:

Description

Core Product Summary

The HIMA X-FAN 18 03 is a system fan module for the HIMax programmable electronic system. It contains four fans and is designed to provide forced-air cooling for a HIMax X-Base Plate 18 01 and the modules installed on it.

The module operates from 24 VDC and draws 0.9 A. It includes a monitoring signal, allowing the fan function to be monitored within the HIMax system. The X-FAN 18 03 is installed as a slide-in module in the HIMax base-plate arrangement and is supplied as a complete four-fan assembly.

 

Key Technical Specifications

Category Specification
Product type HIMax system fan module
Model X-FAN 18 03
Part number 993201813
Number of fans 4
Intended base plate HIMax X-Base Plate 18 01
Supply voltage 24 VDC
Current consumption 0.9 A
Monitoring signal Yes
Mounting method Slide-in module for HIMax base-plate arrangement
Assembly type Complete four-fan assembly
Function Forced-air cooling for HIMax modules and base plate

 

Engineering Selection Highlights

  • The X-FAN 18 03 is specifically a four-fan cooling module for the HIMax X-Base Plate 18 01, so it should be selected for that HIMax base-plate configuration.
  • Its 24 VDC, 0.9 A power requirement must be included in the HIMax system power budget.
  • The integrated monitoring signal supports supervision of the fan function in the HIMax system.
  • The module is supplied as a complete four-fan assembly, which supports replacement of the cooling function as a unit.
  • The slide-in mounting arrangement matches the HIMax base-plate installation method.
  • Forced-air cooling is relevant where the installed HIMax modules and cabinet layout require active ventilation.
X-FAN 18 03

X-FAN 18 03

X-FAN 18 03

X-FAN 18 03

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
Automation system HIMA HIMax programmable electronic system The fan module is part of the HIMax system hardware.
Base plate HIMax X-Base Plate 18 01 The module is designed for this base-plate configuration.
Power supply 24 VDC The module draws 0.9 A.
Monitoring Integrated monitoring signal Allows fan-function monitoring within the HIMax system.
Installation Slide-in module Install in the designated HIMax base-plate fan position.

 

Dimensions, Mounting & Connection Notes

Item Verified data
Fan configuration 4 fans
Mounting method Slide-in module
Intended location HIMax X-Base Plate 18 01
Supply connection 24 VDC
Current consumption 0.9 A
Monitoring connection Integrated monitoring signal
Assembly Complete four-fan assembly

 

Detailed Product Overview

The HIMA X-FAN 18 03 is a system fan module for the HIMax programmable electronic system. It contains four fans arranged as a complete cooling assembly and is designed for installation in the HIMax X-Base Plate 18 01.

The module operates from 24 VDC and draws 0.9 A. Its purpose is to provide forced-air cooling for the HIMax base plate and the modules mounted on it. By supplying airflow across the installed HIMax hardware, the fan module supports thermal management within the control-system rack.

The X-FAN 18 03 includes a monitoring signal. This allows the fan function to be monitored as part of the HIMax system, supporting detection of a cooling-function fault within the system architecture.

The module is installed as a slide-in assembly in the HIMax base-plate arrangement. It is supplied as a complete four-fan module, so the cooling function is replaced as an assembly rather than as individual fans.

 

Applications & System Role

The X-FAN 18 03 provides active forced-air cooling within a HIMA HIMax control-system rack. It moves air across the HIMax X-Base Plate 18 01 and the modules installed on it, supporting thermal management for the controller, system modules, and I/O modules.

Its monitoring signal allows the HIMax system to supervise the cooling function. The module is positioned as part of the HIMax base-plate hardware rather than as a general-purpose cabinet fan.

Typical fit scenarios are HIMax installations using the X-Base Plate 18 01 where the system design requires forced-air cooling and fan-function monitoring.

 

FAQ

What is the HIMA X-FAN 18 03?
The HIMA X-FAN 18 03 is a four-fan system cooling module for the HIMax programmable electronic system.

Which base plate is the X-FAN 18 03 designed for?
It is designed for the HIMax X-Base Plate 18 01.

How many fans does the X-FAN 18 03 contain?
It contains four fans and is supplied as a complete four-fan assembly.

What power does the X-FAN 18 03 require?
It operates from 24 VDC and draws 0.9 A.

Does the X-FAN 18 03 include monitoring?
Yes. It includes a monitoring signal for supervising the fan function within the HIMax system.

How is the X-FAN 18 03 installed?
It is installed as a slide-in module in the HIMax base-plate arrangement.