Description
Core Product Summary
The Honeywell SPS5710 is an industrial power supply module used to provide regulated 24 VDC system power in Honeywell process control and safety system cabinets. It converts a wide-range AC mains input — 100–240 Vac at 47–63 Hz — into a nominal 24 VDC output at up to 20 A, supplying controllers, I/O modules and communication equipment inside the rack.
The unit is designed for redundant power architectures: it can operate in parallel in a redundant configuration, and its hot-swappable design allows a module to be replaced without powering down the rack. Built-in overcurrent, overvoltage and short-circuit protection protects both the module and the system it feeds. In procurement terms, SPS5710 is most commonly referenced under part number 51199929-100, with the SPS5710-2-LF variant referenced under 51198685-100; buyers should confirm the exact part number suffix against the nameplate of the unit being replaced.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Industrial power supply module for control and safety system racks |
| Manufacturer | Honeywell |
| Model | SPS5710 (commonly referenced with part number 51199929-100; SPS5710-2-LF variant referenced as 51198685-100) |
| Input voltage | 100–240 Vac |
| Input frequency | 47–63 Hz |
| Output voltage | Nominal 24 VDC (24–26 VDC range) |
| Output current | Up to 20 A |
| Redundancy | Supports redundant/parallel power supply configuration |
| Replaceability | Hot-swappable module replacement |
| Protection functions | Overcurrent, overvoltage and short-circuit protection |
| Cooling | Natural (passive) convection cooling |
| Mounting | Rack/cabinet installation in the system power position |
Engineering Selection Highlights
- Match the exact part number variant. SPS5710 units circulate under more than one Honeywell part reference (51199929-100; SPS5710-2-LF under 51198685-100); before ordering, verify the part number and revision on the module nameplate rather than relying on the SPS5710 series name alone.
- Output matches a 24 VDC system bus. With a nominal 24 VDC output at up to 20 A, the module is sized to feed controller and I/O power buses typical of Honeywell DCS and safety instrumented system (SIS) cabinets; confirm the rack’s load budget before adding or replacing units.
- Wide-range input simplifies site power compatibility. The 100–240 Vac, 47–63 Hz input covers both 120 V and 230 V mains environments without hardware changes, which matters when the same spare is used across cabinets in different supply regions.
- Redundant operation is a design feature, not an afterthought. The module is intended to run in redundant parallel configurations; a single unit should not be treated as full system coverage where the cabinet design specifies N+1 or dual power feeds.
- Hot swap keeps the rack powered during maintenance. The module can be replaced while the system continues running on the remaining supply, so maintenance planning does not require a process shutdown — provided the redundant partner unit is healthy first.
- Passive cooling constrains cabinet ventilation. Natural convection cooling means the module’s thermal performance depends on cabinet airflow; verify rack ventilation and ambient conditions against the installation documentation for the host system.

SPS5710

SPS5710
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Host system | Honeywell process control and safety system racks requiring 24 VDC system power | Confirm the cabinet power architecture against the host system’s hardware documentation before ordering |
| Mains input | 100–240 Vac, 47–63 Hz | Covers 120 V and 230 V supplies; verify cabinet feeder voltage and breaker sizing |
| System bus | 24 VDC output, up to 20 A | Check total rack load and redundant capacity against the 20 A output |
| Redundant configuration | Parallel operation supported | Verify that both supply slots and wiring are present if redundancy is required |
| Replacement procedure | Hot-swappable | Replace only with the redundant partner confirmed healthy; follow lock-out/tag-out for the AC feeder during removal |
| Protection behavior | Overcurrent, overvoltage and short-circuit protection built in | The module protects itself and the 24 VDC bus; upstream AC protection still required per cabinet wiring standards |
Detailed Product Overview
Power supply modules are easy to treat as commodity items, yet in a safety or control system rack the supply is a single point of failure for every module behind it. The Honeywell SPS5710 is engineered around that reality, and three of its design characteristics carry most of the engineering meaning.
The first is the wide-range AC input. Accepting 100–240 Vac at 47–63 Hz means one module type serves cabinets fed from 120 V North American supplies as well as 230 V supplies common elsewhere. For a buyer maintaining spares across an international installed base, that reduces the number of supply variants that must be stocked, and it removes the risk of installing a unit on a mains for which it was not wound.
The second is the 24 VDC, 20 A output. Twenty amps is in the range needed to power a fully populated controller and I/O card file, so a single module typically carries the whole rack’s electronics. The practical selection question is load budget: the rack’s actual 24 VDC consumption, including inrush and future I/O expansion, must fit within the module’s rating, and in redundant cabinets each unit must be able to carry the full load alone, not merely half of it.
The third is redundancy and hot swap. The module is designed to operate in parallel with a second unit. When both are healthy they share the load; when one trips or is pulled, the other continues without interruption. Hot-swappability turns what would otherwise be a planned shutdown into a routine exchange. The discipline this imposes on maintenance practice is worth stating: never pull a supply module unless the remaining unit has first been confirmed healthy and carrying the load, and de-energize and lock out the AC feeder before handling.
The protection functions define the failure behavior. Overcurrent, overvoltage and short-circuit protection means a fault on the 24 VDC bus or within the module causes the module to shut down its output rather than propagate the fault into the rack electronics. This is a fail-protective design: the module sacrifices itself ahead of the controller and I/O. Passive convection cooling eliminates a fan as a wear item, but it makes the surrounding cabinet the heatsink; rack ventilation, mounting orientation and spacing around the module therefore remain part of the installation requirement, as defined in the host system’s installation documentation.
For identification in the field, SPS5710 units carry the series designation together with a Honeywell part number — most commonly 51199929-100, with the SPS5710-2-LF variant referenced under 51198685-100. Because variant suffixes can reflect functional or hardware differences, the part number on the nameplate, not the series name, is the correct ordering reference. Where a cabinet’s power architecture or certification scope is part of a safety case, the replacement supply should be verified against the host system’s hardware documentation to confirm the exact part number and configuration the system was built with.
Applications & System Role
The SPS5710 occupies the power supply position in Honeywell industrial control and safety cabinets. Its role is fundamental: it converts plant AC mains into the regulated 24 VDC that the rack’s controllers, I/O modules and communication equipment run on. Every function in the cabinet depends on this supply, which is why the module is designed for redundant parallel operation and hot replacement.
In redundant configurations, two supply modules share the load; if one fails or is removed, the surviving unit continues to power the system. This is the standard architecture for safety instrumented systems, emergency shutdown systems, burner management systems and distributed control system nodes where loss of control power is unacceptable. The hot-swap capability makes the module a routine maintenance item: a failed or suspect unit can be exchanged without shutting down the process, provided redundancy is intact.
Because the same 24 VDC bus feeds the safety logic solver and its I/O, power supply health is part of the overall system availability concept. For procurement teams, SPS5710 is typically purchased as a spare for existing cabinets rather than as a new-build component; the correct selection action is to match the part number on the installed unit, not only the series designation.
FAQ
What is the Honeywell SPS5710?
It is an industrial power supply module that converts a 100–240 Vac mains input into a regulated 24 VDC output at up to 20 A for use in Honeywell control and safety system racks.
What is SPS5710 used for?
It powers the controllers, I/O modules and communication equipment inside process control and safety instrumented system cabinets, typically in a redundant pair to avoid a single point of failure.
What input voltage does SPS5710 accept?
It accepts 100–240 Vac at 47–63 Hz, covering both 120 V and 230 V mains environments.
What output does SPS5710 provide?
A nominal 24 VDC output (24–26 VDC range) with a continuous output current of up to 20 A.
Can SPS5710 be replaced while the system is running?
Yes, the module is hot-swappable, but it should only be removed after confirming that the redundant partner supply is healthy and carrying the rack load.
Does SPS5710 support redundant operation?
Yes, it is designed for parallel redundant configuration with a second supply module, which is the recommended architecture for safety-critical racks.
Which part number should I order for SPS5710?
The module is most commonly referenced under Honeywell part number 51199929-100, with the SPS5710-2-LF variant referenced under 51198685-100; always match the exact part number on the installed unit’s nameplate.
What protection functions are built into SPS5710?
The module includes overcurrent, overvoltage and short-circuit protection, so a bus or internal fault causes the module to shut down its output rather than pass the fault to the rack electronics.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626