The Honeywell TK-RPCXX1 (Order Code: 51402572-100 / 51402572-200 / 97332572) is a conformal-coated redundant power supply module designed for Honeywell’s Experion Process Knowledge System (PKS) and C200 control chassis. Engineered to provide stable power distribution across system backplanes, this unit delivers multiple regulated DC output rails to power processing cards, communication interfaces, and local I/O chassis assemblies.
Featuring a universal AC input range (85–265 VAC at 47–63 Hz) and delivering a maximum total power output of 75 Watts at 60°C, the TK-RPCXX1 supports active dual-power redundancy. When paired with a second supply via dedicated interconnect cabling, it allows seamless load sharing and instant failover without disrupting controller operation. The “TK” designation highlights its factory-applied conformal coating, protecting internal circuitry against humidity, airborne contamination, and corrosive atmospheric gases in harsh process environments.
Key Technical Specifications
| Specification Parameter | Technical Value / Standard |
| Manufacturer | Honeywell |
| Model / Part Number | TK-RPCXX1 (Coated Variant of TC-RPCXX1) |
| Assembly / Board Part Numbers | 51402572-100 / 51402572-200 / 97332572 |
| Product Category | Redundant AC Power Supply Module |
| System Compatibility | Honeywell Experion PKS / C200 Controller Chassis |
| Input Voltage Range | 85 to 265 VAC (Single-Phase, Universal Input) |
| Input Frequency | 47 to 63 Hz |
| Input Power / Apparent Power | 110 W / 120 VA nominal |
| Maximum Inrush Current | 20 A peak |
| Total Power Output | 75 W maximum @ 60°C |
| Backplane Output Voltage Rails | 1.2 VDC, 3.3 VDC, 5.1 VDC, and 24.0 VDC |
| Maximum Backplane Current | 1.5A @ 1.2V / 4.0A @ 3.3V / 13.0A @ 5.1V / 2.8A @ 24.0V |
| Annunciator / Status Contact | Solid-state relay rated for 120 VAC/DC @ 100 mA max |
| Environmental Protection | Conformal Coated PCB (TK Series) |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
| Dimensions (H × W × D) | 17.5 cm × 14.4 cm × 13.7 cm (6.89 in × 5.67 in × 5.39 in) |
| Approximate Weight | 1.1 kg (2.5 lbs) |
Detailed Product Overview
The Honeywell TK-RPCXX1 functions as the central power conversion engine within Experion PKS chassis configurations. It converts primary plant utility AC voltage into low-noise DC power rails that energize control processors, network gateway modules, and chassis backplane buses.
Designed for high availability, the TK-RPCXX1 integrates an active redundancy bus connection. When two RPCXX1 modules are connected using an external redundant power cable (such as model TC-RPSC03), the units share internal chassis current loads equally. In the event of an AC utility failure, internal component fault, or power cord disconnection on one module, the companion unit instantaneously assumes 100% of the chassis load without causing voltage sags or controller resets.
The factory conformal coating protects fine-trace circuit paths, power switching semiconductors, and surface-mount components from Class G3 industrial environments. Integrated solid-state alarm contacts allow diagnostic relay signals (Power OK / Power Fail) to be wired directly into supervisory monitoring systems or visual control panel annunciators.

TK-RPCXX1

TK-RPCXX1
Engineering Selection Highlights
- Factory Conformal Coating (TK Series): Provides specialized moisture and chemical resistance for deployment in sulfur-rich or humid processing facilities.
- Universal AC Line Acceptance: Accepts wide-range 85–265 VAC input, accommodating global industrial voltages without manual tap changes or transformer adjustments.
- Seamless Dual Redundancy: Enables fault-tolerant 1+1 redundant power architecture when linked with a matching supply and TC-RPSC03 cable.
- Multi-Rail Backplane Output: Simultaneously supplies 1.2V, 3.3V, 5.1V, and 24V DC to satisfy the diverse voltage demands of modern control cards.
- Hardware Status Annunciation: Integrated solid-state relay contact outputs enable real-time monitoring of power supply health by PLCs or supervisory systems.
System Compatibility & Integration Requirements
| System Component / Layer | Compatibility / Integration Requirement | Practical Note |
| Control System Platform | Honeywell Experion PKS / C200 System | Serves as main AC power supply module for system chassis. |
| Redundant Power Cable | Requires TC-RPSC03 (3 ft cable) or equivalent | Mandatory for linking dual TK-RPCXX1 units in a redundant pair. |
| Chassis Mounting | Mounts directly above or below the target chassis | Requires upright vertical orientation to support convective airflow. |
| Input Power Wiring | Standard #14 AWG (1.4 mm) conductors | Connect to dedicated, fused AC supply lines for maximum uptime. |
Dimensions, Mounting & Connection Notes
- Physical Dimensions: Measures 17.5 cm (H) × 14.4 cm (W) × 13.7 cm (D).
- Mounting Orientation: Installed vertically in designated power supply slots above or below the main C200/Experion chassis frame.
- Weight: Module weight is approximately 1.1 kg (2.5 lbs).
- Cooling Clearances: Maintain recommended vertical clearances above and below the module housing to allow adequate thermal convection.
- Annunciator Cable Connection: Wire the solid-state status output block using shielded twisted-pair signal wire to prevent false power-fail alarms in high-EMI environments.
FAQ
What is the difference between Honeywell TK-RPCXX1 and TC-RPCXX1?
Both modules share identical electrical specs and physical dimensions; however, the “TK” designation indicates that the circuit assembly is factory conformal-coated for enhanced corrosion protection in harsh industrial environments.
What input voltage range does the TK-RPCXX1 support?
The module features a universal AC input range supporting 85 to 265 VAC single-phase power at 47 to 63 Hz.
What is the maximum output power rating of the TK-RPCXX1?
The module provides up to 75 Watts total power output at an operating ambient temperature of 60°C.
Is an additional cable required to configure redundant power supplies?
Yes, connecting two TK-RPCXX1 units in a redundant configuration requires a dedicated interconnect cable, such as the 3-foot Honeywell TC-RPSC03 cable.
What DC output voltages does the unit supply to the backplane?
It supplies four regulated DC voltage rails: 1.2 VDC, 3.3 VDC, 5.1 VDC, and 24.0 VDC.
Verification & Troubleshooting Notes
- LED Diagnostic Indicators: Check the front-panel status LEDs during system startup: a solid green indicator confirms normal output rail voltages, while an unlit or red LED indicates an input AC outage, blown fuse, or internal fault.
- Annunciator Contact Testing: Verify proper operation of the solid-state alarm contact (120 VAC/DC @ 100 mA max) by testing continuity under powered and unpowered states to ensure remote power-fail monitoring is functional.
- Redundancy Cable Seating: Ensure the TC-RPSC03 inter-module cable is fully seated and locked at both ends; loose cable connections can prevent current sharing and trigger false redundancy alarms.
- Thermal Inspection: Periodically check for unobstructed convective ventilation around the power supply housing; excessive cabinet heat buildup can reduce available output power or trigger thermal shutdown mechanisms.