Core Product Summary
The ICS Triplex T8314 is a Trusted Fibre Transmitter/Receiver (TX/RX) Unit for the ICS Triplex Trusted automation platform. It converts the differential signals of the copper-based Trusted Expander Bus into fiber-optic signals for transmission over single-mode fiber, allowing a Trusted Expander Chassis to be located remotely from the Trusted system.
The T8314 supports Trusted Expander Bus distances up to 10 km and operates at a fiber data rate of 250 Mb/s. It is DIN-rail mounted, accepts dual 24 Vdc supplies through diode-ORed power inputs, and uses SC connectors for separate transmit and receive fibers. Three independent pairs of T8314 units provide a non-interfering “Grey Channel” approach for Trusted expansion communications.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | ICS Triplex |
| Exact model | T8314 |
| Product type | Trusted Fibre TX/RX Unit |
| Product family | ICS Triplex Trusted |
| Function | Converts copper Expander Bus signals to single-mode fiber-optic signals |
| Expansion distance | Up to 10 km |
| Fiber data rate | 250 Mb/s |
| Fiber type | Single-mode fiber |
| Fiber connectors | Two SC connectors, one transmit and one receive |
| Power inputs | Dual 24 Vdc, diode-ORed |
| Supply voltage range | 18–32 Vdc |
| Power consumption | 1.7 W maximum |
| Transmitter power | -15 dBm minimum into the fiber cable |
| Receiver sensitivity | -28 dBm |
| Maximum propagation-time difference | 80 ns |
| Maximum fiber-length difference | 15 m |
| Mounting | TS32 or TS35 DIN rail, horizontal or vertical |
| Required clearance | Minimum 200 mm on either side for fiber bend radius |
| Operating temperature | 0 to +60 °C (+32 to +140 °F) |
| Non-operating temperature | -25 to +70 °C (-13 to +158 °F) |
| Relative humidity | 10% to 95%, non-condensing |
| Dimensions | 84 mm H × 110 mm W × 40 mm D |
| Weight | 320 g |
| Certification | Ordinary location, hazardous location, ATEX, IECEx |
Engineering Selection Highlights
- The T8314 is a Trusted Fibre TX/RX Unit, so it is used to extend the Trusted Expander Bus rather than to provide process I/O or controller processing.
- Its 10 km fiber transmission capability allows a Trusted Expander Chassis to be installed remotely from the Trusted controller system.
- The unit converts copper Expander Bus differential signals to single-mode fiber signals, making it suitable where electrical isolation, distance, or cable-route requirements make copper expansion impractical.
- Three independent pairs of T8314 units form the non-interfering Grey Channel arrangement used for Trusted expansion communications.
- Six T8314 units and six fibers are required for each remote link, with three units and three fibers installed at each end.
- The dual 24 Vdc diode-ORed power inputs allow operation from either a dual or single power source, depending on the system power design.
- Fiber routing must keep the propagation-time difference between the three links within 80 ns, equivalent to a maximum fiber-length difference of 15 m; for links longer than 2 km, route surveying is required.

T8314

T8314
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Trusted system family | ICS Triplex Trusted | The T8314 is part of the Trusted Expander Bus architecture. |
| Trusted Expander Processor | T8310 | The remote Expander Processor connects to the T8314 through TC-303 cable. |
| Expander Interface Adapter | T8312 | The T8312 connects to the T8314 through TC-302 cable. |
| Expansion medium | Single-mode fiber with SC connectors | Separate transmit and receive fibers are required. |
| Remote link configuration | Six T8314 units and six fibers per remote link | Three units and three fibers are located at each end. |
| Copper Expander Bus | Differential Expander Bus signals | The T8314 converts these signals to and from fiber-optic form. |
| Power supply | Dual 24 Vdc diode-ORed inputs, 18–32 Vdc | The unit can be powered from a dual or single source. |
| Fiber route | Maximum 80 ns propagation-time difference; maximum 15 m fiber-length difference | Routes longer than 2 km require a survey for propagation delay and IMB timeout compliance. |
Dimensions, Mounting & Connection Notes
The ICS Triplex T8314 measures 84 mm high, 110 mm wide, and 40 mm deep, and weighs 320 g. It mounts on either a TS32 or TS35 DIN rail and can be installed horizontally or vertically as required by the cabinet layout.
The unit has two SC fiber connectors for separate transmit and receive single-mode fibers. Its Expander Bus connection uses a four-way interface with TX+, TX-, RX-, and RX+ signals. Power is connected through four terminals: +24 Vdc 1, 0 V1, 0 V2, and +24 Vdc 2. The two 24 Vdc supplies are diode-ORed, allowing operation from either a dual or single source.
A minimum clearance of 200 mm should be allowed on either side of the unit to accommodate the fiber cable bend radius. The applicable bend radius depends on the selected fiber cable.
Detailed Product Overview
The ICS Triplex T8314 is a fiber-optic transmitter/receiver unit used to extend the Trusted Expander Bus in an ICS Triplex Trusted system. It converts the differential electrical signals used on the copper Expander Bus into optical signals for transmission over single-mode fiber, and performs the reverse conversion at the other end of the link.
The T8314 enables a Trusted Expander Chassis to be located remotely from the Trusted system. This is useful where physical separation, cabinet layout, or distance requirements prevent the use of copper Expander Bus cabling. The unit supports fiber links up to 10 km and transmits data at 250 Mb/s.
A remote Trusted expansion link uses three independent pairs of T8314 units. Each pair forms one of the three non-interfering Grey Channels, and each channel uses separate transmit and receive fibers. Therefore, a complete remote link requires six T8314 units and six fibers: three units and three fibers at each end.
The T8314 connects to the Trusted Expander Interface Adapter T8312 through TC-302 cable and to the remote Trusted TMR Expander Processor T8310 through TC-303 cable. This cable arrangement defines the unit’s position in the Trusted expansion architecture: it sits between the controller-side Expander Interface Adapter and the remote Expander Processor.
The unit accepts two 24 Vdc power inputs that are diode-ORed internally. It can therefore be powered from either a dual-redundant supply arrangement or a single supply, according to the installed power design. Its operating voltage range is 18–32 Vdc, with maximum power consumption of 1.7 W.
Fiber routing requires attention to timing. The propagation-time difference between the shortest and longest of the three fiber links must not exceed 80 ns, equivalent to a fiber-length difference of 15 m. For fiber routes longer than 2 km, the route must be surveyed to ensure that this difference and the round-trip delay remain within the Inter-Module Bus timeout requirement.
Applications & System Role
Within a Trusted automation architecture, the ICS Triplex T8314 provides the fiber-optic extension of the Trusted Expander Bus between a Trusted controller system and a remote Trusted Expander Chassis. It enables the Expander Chassis and its T8310 Expander Processor to be installed away from the main Trusted system while maintaining the Trusted expansion communication architecture.
The unit is relevant where the distance between chassis locations exceeds the 30 m limit of TC-301 copper expansion cable. By converting the Expander Bus to single-mode fiber, it supports remote chassis placement up to 10 km away, subject to the fiber route’s propagation-time and IMB-timeout requirements.
FAQ
What is the ICS Triplex T8314?
The ICS Triplex T8314 is a Trusted Fibre TX/RX Unit that converts Trusted Expander Bus signals between copper and single-mode fiber.
What is the T8314 used for?
It extends the Trusted Expander Bus over fiber-optic cable, allowing a Trusted Expander Chassis to be located remotely from the Trusted system.
What is the maximum fiber distance supported?
The T8314 supports Trusted Expander Bus distances up to 10 km.
How many T8314 units are required for a remote link?
A remote link requires six T8314 units and six fibers, with three units and three fibers at each end.
Which Trusted modules connect to the T8314?
It connects to the Trusted Expander Interface Adapter T8312 through TC-302 cable and to the remote Trusted TMR Expander Processor T8310 through TC-303 cable.
What type of fiber and connector does it use?
It uses single-mode fiber with SC-type connectors for separate transmit and receive fibers.
How is the T8314 powered?
It uses dual 24 Vdc diode-ORed power inputs and operates from an 18–32 Vdc supply range.
What installation clearance is required?
A minimum of 200 mm should be allowed on either side of the unit to accommodate the fiber cable bend radius.