Sale!

ICS Triplex T9892 AADvance 8-Channel Dual Digital Output Termination Assembly

Parameter Specification
Brand ICS Triplex
Exact model T9892
Product type Digital Output Termination Assembly
Product family Rockwell Automation AADvance / ICS Triplex
Number of output channels 8
Configuration Dual
Companion output module AADvance T9451 Digital Output Module
Field-power connection Separate field power input voltage connector
Categories: , , , , SKU: T9892 Brand:

Description

Core Product Summary

The ICS Triplex T9892 is an 8-channel dual Digital Output Termination Assembly for the Rockwell Automation AADvance controller platform. It operates with the AADvance T9451 Digital Output Module and provides the field-wiring interface for eight dual-configuration digital output channels.

The T9892 shares the same pin-out and coding-peg configuration as the standard AADvance T9852 Digital Output Termination Assembly. Its distinguishing feature is a separate connector for field power input voltage connections. The assembly uses screw-clamp terminals and is installed vertically on the AADvance I/O base unit.

 

Key Technical Specifications

Parameter Specification
Brand ICS Triplex
Exact model T9892
Product type Digital Output Termination Assembly
Product family Rockwell Automation AADvance / ICS Triplex
Number of output channels 8
Configuration Dual
Companion output module AADvance T9451 Digital Output Module
Field-power connection Separate field power input voltage connector
Field terminal type Screw-clamp terminals
Pin-out Same as AADvance T9852 Digital Output Termination Assembly
Coding-peg configuration Same as AADvance T9852 Digital Output Termination Assembly
Installation orientation Vertical only
Product category Mechanical field-termination accessory

 

Engineering Selection Highlights

  • The T9892 is a dual 8-channel Digital Output Termination Assembly, so it should be selected for AADvance digital output systems using the T9451 output module in a dual configuration.
  • It provides eight dual-configuration output channels, allowing two output modules to share the termination arrangement.
  • The assembly’s separate field-power input connector distinguishes it from the standard T9852 and should be considered when planning field-power wiring.
  • Its pin-out and coding-peg configuration match the T9852, so mechanical compatibility should be checked against the installed AADvance base unit and cable arrangement.
  • The T9892 uses screw-clamp terminals for field connections and must be installed in the vertical orientation only.
  • The assembly is a mechanical termination accessory and does not provide output switching, diagnostics, or communication functions.
 T9892

T9892

 T9892

T9892

System Compatibility & Integration Requirements

Item / Dependency Verified Compatibility or Requirement Practical Note
AADvance controller family Rockwell Automation AADvance / ICS Triplex The T9892 is an AADvance field-termination accessory.
Output module AADvance T9451 Digital Output Module The T9892 operates in conjunction with this module.
I/O configuration Dual, 8-channel output configuration The assembly provides eight dual-configuration output channels.
Related termination assembly AADvance T9852 The T9892 has the same pin-out and coding-peg configuration as the T9852.
Field power Separate field power input voltage connector Field power is connected through a dedicated connector rather than the standard T9852 arrangement.
Field wiring Screw-clamp terminals Field wiring is terminated at the assembly’s screw-clamp terminals.
Installation orientation Vertical only The termination assembly must be installed vertically.

 

Dimensions, Mounting & Connection Notes

The ICS Triplex T9892 is an AADvance Termination Assembly that mounts on the AADvance I/O base unit. It provides screw-clamp terminals for eight dual-configuration digital output field loops.

The assembly has a separate connector for field power input voltage connections. This is the principal wiring difference from the standard AADvance T9852 Digital Output Termination Assembly. The T9892 shares the same pin-out and coding-peg configuration as the T9852.

The termination assembly must be installed in the vertical orientation only. During replacement, the existing I/O modules are removed, field wiring is identified and disconnected, the termination assembly is released from its retaining tabs, and the replacement assembly is inserted into the I/O base unit before the I/O modules are reinstalled.

 

Detailed Product Overview

The ICS Triplex T9892 is an 8-channel dual Digital Output Termination Assembly for the AADvance controller platform. It is part of the AADvance field-termination range and operates with the AADvance T9451 Digital Output Module.

The T9892 provides eight dual-configuration output channels. It shares the same pin-out and coding-peg configuration as the standard AADvance T9852 Digital Output Termination Assembly, which makes it mechanically compatible with the corresponding AADvance base-unit and cable arrangement.

The distinguishing feature of the T9892 is its separate connector for field power input voltage connections. This arrangement differs from the standard T9852 and should be considered when designing the field-power distribution and cabinet wiring layout.

The assembly uses screw-clamp terminals for field connections. Like other AADvance termination assemblies, it must be installed in the vertical orientation only. The AADvance maintenance documentation describes termination-assembly replacement as a procedure involving removal of the associated I/O modules, identification and disconnection of field wiring, release of the retaining tabs, and installation of the replacement assembly.

As a mechanical termination accessory, the T9892 does not provide output switching, signal processing, diagnostics, or communication functions. Those functions are performed by the associated AADvance T9451 Digital Output Module and controller architecture.

 

Applications & System Role

Within an AADvance automation architecture, the ICS Triplex T9892 provides the physical field-wiring interface between the AADvance T9451 Digital Output Module and digital field devices in a dual output configuration. It terminates the field wiring, receives field power through a dedicated connector, and routes output signals to the field terminals.

The assembly is relevant for AADvance controllers that use dual digital output architectures and require a termination assembly with separate field-power input connections. It is a mechanical accessory and does not participate directly in output switching, safety logic, communications, or diagnostics.

 

FAQ

What is the ICS Triplex T9892?
The ICS Triplex T9892 is an 8-channel dual Digital Output Termination Assembly for the AADvance controller platform.

Which AADvance output module does the T9892 work with?
It operates in conjunction with the AADvance T9451 Digital Output Module.

How many output channels does the T9892 provide?
It provides eight dual-configuration digital output channels.

How does the T9892 differ from the T9852?
It has the same pin-out and coding-peg configuration as the T9852, but includes a separate connector for field power input voltage connections.

Does the T9892 provide output switching or diagnostics?
No. It is a mechanical termination assembly; output switching and diagnostics are performed by the associated AADvance output module and controller architecture.

What type of field terminals does it use?
It uses screw-clamp terminals for field connections.

Can the T9892 be mounted horizontally?
No. AADvance termination assemblies must be installed in the vertical orientation only.