The INFICON PSG400 (Order Number 350-000) is a compact, high-precision Pirani Standard Vacuum Gauge designed for reliable vacuum measurement across forevacuum and process lines. Operating on INFICON’s patented twin-Pirani filament technology, the gauge measures system pressure across a wide sensing range from 3.8 \times 10^{-4} Torr to 750 Torr (5 \times 10^{-4} mbar to 1000 mbar).
Built with a stainless steel and tungsten sensor cell, the PSG400 converts pressure measurements into a logarithmic 0 to +10.3 V DC analog output signal for seamless integration with PLCs, data acquisition modules, and vacuum controllers. The unit is powered by a standard 14 to 32 V DC supply, consumes a maximum of 1 W, and utilizes an 8-pin shielded FCC-68 (RJ45-style) connector interface. Its small footprint and orientation-independent mounting make it ideal for semiconductor manufacturing systems, vacuum coating, analytical instruments, and general industrial vacuum monitoring.
Key Technical Specifications
| Parameter | Verified Specification Value |
| Manufacturer & Model | INFICON Pirani Standard Gauge PSG400 (e.g., 350-000 for DN 16 ISO-KF) |
| Measurement Range | 3.8 \times 10^{-4} to 750 Torr (5 \times 10^{-4} to 1000 mbar) |
| Measurement Principle | Thermal conductivity (Patented Twin Pirani technology) |
| Accuracy (1 \times 10^{-2} to 100 mbar) | \approx \pm 10\% of reading |
| Repeatability (1 \times 10^{-3} to 100 mbar) | \approx \pm 2\% of reading |
| Analog Output Signal | Logarithmic 0 to +10.3 V DC (1.286 V/decade) |
| Response Time | 10 ms |
| Supply Voltage Range | 14 to 32 V DC |
| Power Consumption | Max 1 W |
| Connector Type | FCC-68, 8-pin shielded (RJ45 style) |
| Max Cable Length (Analog) | 100 m (330 ft) |
| Media Wetted Materials | Tungsten, Stainless Steel, Copper, Glass, NiFe, Nickel |
| Maximum Overpressure | 10 bar absolute |
| Enclosure Rating | IP40 |
| Operating Temperature | +5°C to +60°C |
| Weight (DN 16 ISO-KF) | 290 g |
Detailed Product Overview
The INFICON PSG400 Pirani Standard Gauge serves as a compact pressure transducer in high-vacuum systems, load locks, forevacuum lines, and automated vacuum process tools. Utilizing patented twin-filament thermal conductivity technology, the gauge maintains measurement stability across its operating range from deep sub-millibar levels up to atmospheric pressure.
The internal sensor cell features low-outgassing, process-compatible materials including tungsten filaments, stainless steel housing, copper, and nickel-iron feedthroughs. By generating a logarithmic analog output calibrated at 1.286 Volts per decade, the sensor allows control automation systems to monitor vacuum levels continuously without manual range switching.
Designed for flexibility, the PSG400 operates reliably in any physical mounting orientation. Its integrated electronics are housed in a compact aluminum enclosure rated IP40, minimizing space requirements near vacuum flanges. The unit connects directly to dedicated vacuum display controllers (such as the INFICON VGC series) or industrial analog input cards via a standard shielded 8-pin FCC-68 port.

PSG400

PSG400
Engineering Selection Highlights
- Wide Measurement Range: Spans sub-millibar pressures (3.8 \times 10^{-4} Torr) up to atmospheric pressure (750 Torr), eliminating the need for separate roughing and fine-vacuum sensors.
- Patented Twin Pirani Design: Enhances sensor lifetime, response speeds (10 ms), and signal stability over standard single-filament designs.
- Compact Footprint: Extremely small dimensions and lightweight construction allow direct installation onto tight process manifolds and OEM vacuum tools.
- Logarithmic Voltage Output: Scaled at 1.286 V per decade over a 0 to +10.3 V range for straightforward scaling on PLC or DCS analog inputs.
- Flexible Installation: Performs accurately in horizontal, vertical, or inverted mounting positions without recalibration.
Dimensions, Mounting & Connection Notes
The PSG400 features a compact cylindrical sensor assembly weighing approximately 290 g (DN 16 ISO-KF version). The unit mounts directly to a matching vacuum fitting using standard centring rings, quick-release clamps, or metal-gasket seals depending on the specific flange configuration. Mounting orientation is completely arbitrary.
Electrical interfacing is provided through a single top-mounted, shielded 8-pin FCC-68 socket. The cable shield must be grounded appropriately to prevent electromagnetic interference from surrounding high-voltage or RF equipment. The gauge flange allows high-temperature bakeout up to 80°C with the electronic unit attached.
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
| Vacuum Flange Interface | DN 16 ISO-KF (Part No. 350-000) or 1/8″ NPT, DN 16 CF, 1/2″ Tube, 8 VCR options | Must match vacuum manifold connection type; gasket/centering ring required. |
| Electrical Cable / Connector | Shielded 8-pin FCC-68 (RJ45 style) cable | Cable length can extend up to 100 meters (330 feet) without signal degradation. |
| Power Supply Requirement | 14 to 32 V DC filtered power source | Draw is capped at 1 W; can be powered via host controller or external supply. |
| Compatible Controllers | INFICON VGC501 / VGC502 / VGC503 or generic 0–10V PLC analog input | Direct plug-and-play pinouts available on INFICON gauge display units. |
FAQ
What is the INFICON PSG400?
The INFICON PSG400 is a compact, high-precision Pirani Standard Vacuum Gauge used to measure pressure in vacuum systems and forelines.
What pressure range does the PSG400 measure?
The PSG400 measures vacuum pressure from 3.8 \times 10^{-4} Torr to 750 Torr (5 \times 10^{-4} mbar to 1000 mbar).
What output signal does the PSG400 provide?
It provides a logarithmic analog voltage output from 0 to +10.3 V DC, scaled at 1.286 Volts per pressure decade.
What power supply is required to operate the PSG400?
The gauge requires a 14 to 32 V DC power source with a maximum power consumption of 1 W.
What electrical connector is on the gauge?
The gauge uses a shielded 8-pin FCC-68 connector socket (RJ45 style) for power and signal transmission.
Can the PSG400 be mounted upside down or at an angle?
Yes, the twin Pirani design functions accurately in any physical orientation.
Verification & Troubleshooting Notes
- Error Voltage Output: An analog output reading below 0.5 V DC indicates a sensor fault, broken filament, or disconnected power/signal line.
- Zero-Point Calibration: If the pressure reading drifts at high vacuum, perform a zero-point adjustment according to the manufacturer manual while the system pressure is known to be well below 10^{-4} mbar.
- Contamination Checks: Exposure to process oil mist, reactive gases, or particulate matter can coat the internal filaments, causing measurement drift. Inspect and replace the gauge head if readings remain inaccurate after recalibration.