Description
Core Product Summary
The IWAKI SC-1 is a menu-driven pump controller for Iwaki pneumatic drive bellows pumps, designed to pace up to three F series pumps simultaneously. It belongs to the family of Iwaki pump controllers built specifically for the FF, FF-H, and FA pneumatic bellows pump series, providing stable, sensor-based control of chemical circulation and filtration systems.
Operation is handled through a keypad and liquid crystal display, with constant speed control, overspeed control, and leak alarm functions. The controller continuously monitors and accumulates flow rate, pressure, and total stroke count, and it accepts input from the pump’s sensors; a timer mode is provided as standard so operation can continue if the proximity switch fails. Serial integration into automated systems is supported through RS-422 or RS-485 ports. The unit runs on a 24 VDC ±10% supply and is rated for ambient temperatures of 0 to 55 °C.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product type | Menu-driven pump controller for pneumatic drive bellows pumps |
| Compatible pumps | Iwaki FF, FF-H, and FA series pneumatic drive bellows pumps |
| Pumps controlled | Up to three pumps simultaneously |
| Control functions | Constant speed control, overspeed control, leak alarm, time-up alarm |
| Monitored parameters | Flow rate, number of strokes, pressure, total count |
| Operating modes | AUTO mode (external signals) and MANU (manual) mode; sensor (proximity switch) mode and timer mode |
| Communication | RS-422 or RS-485 ports |
| Operator interface | Keypad with liquid crystal display |
| Power supply | 24 VDC ±10% |
| Power consumption | 20 VDC or less |
| Ambient temperature | 0 to 55 °C (32 to 131 °F) |
| Outer dimensions | 200 × 110 × 180 mm (7.9 W × 4.3 H × 7.1 D in) |
Detailed Product Overview
The SC-1 occupies a specific role in Iwaki’s F series architecture: it is not a general-purpose drive, but a supervisory controller that paces pneumatic bellows pumps according to what the pump sensors report. Its fixed stroke rate control keeps the pump running at a set number of strokes regardless of load changes on the discharge side — for example, when a downstream filter begins to clog — which is what allows a circulation or filtration loop to hold a stable discharge over time. By keeping the pressure differential across the bellows at a minimum despite changing discharge loads, this control approach also reduces stress on the bellows, which is a direct maintenance consideration for systems that run continuously with aggressive chemicals.
The ability to pace three pumps from a single controller is the SC-1’s defining integration feature. Where a tool or skid uses multiple FF, FF-H, or FA pumps in one chemical loop, a single SC-1 provides coordinated stroke-rate control, monitoring, and alarm handling instead of three separate single-pump controllers. Note that pump coverage is series-specific within the F family: the companion SC-2 controller is the version for FW and FW-H pumps, so the target pump series should be confirmed before specifying a controller.
Operationally, the controller works in two levels. AUTO mode lets an external source start and stop operation, while MANU mode supports local manual operation. Within sensor-based operation, the standard-equipment timer mode serves as a fallback: if the pump’s proximity switch fails, the controller can continue operating the pump in timer mode rather than halting the process. This redundancy matters in circulation systems where an unplanned stop can interrupt temperature control or filtration of a process bath.
Monitoring is continuous rather than on-demand. Flow rate, stroke count, pressure, and total count are tracked and accumulated, giving operators data for verifying that the loop is performing as configured. Alarm coverage includes leak alarm — which stops the pump in an emergency when bellows damage is detected — plus overspeed control and time-up alarm logic that flags abnormally fast strokes.
For integration into a larger automation architecture, the RS-422/RS-485 ports allow the SC-1 to report status and readings to a host system rather than operating as an isolated panel device. This makes it suitable for OEM tool designs and automated chemical delivery systems where pump telemetry must reach a central controller.
Electrical and environmental fit should be checked at the design stage: the unit requires a 24 VDC ±10% supply, is rated for 0 to 55 °C ambient operation, and occupies a panel footprint of 200 × 110 × 180 mm — larger than Iwaki’s single-pump controllers, which reflects its three-pump capability and full keypad/LCD interface.

SC-1
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Compatible pump series | Iwaki FF, FF-H, and FA pneumatic drive bellows pumps | Series-specific; FW and FW-H pumps use the SC-2 controller instead |
| Number of pumps | Up to three pumps controlled simultaneously | One SC-1 can replace three single-pump controllers in a multi-pump loop |
| Sensor input | Output from the pump’s built-in stroke sensor (proximity switch); timer mode available as standard fallback | Operation can continue in timer mode if the proximity switch fails |
| Control inputs | External start/stop signals (AUTO mode); manual MANU mode | Supports remote on/off from a host system or local operation |
| Communication | RS-422 or RS-485 ports | Enables integration into automated systems |
| Power supply | 24 VDC ±10% | Verify DC supply availability in the control panel |
| Companion components | Pulsation dampener and electropneumatic valve used in Iwaki chemical circulation system configurations | Combined with the SC-1 to configure a complete circulation system |
Dimensions, Mounting & Connection Notes
| Item | Verified Value |
|---|---|
| Outer dimensions | 200 × 110 × 180 mm (W × H × D), equivalent to 7.9 × 4.3 × 7.1 in |
| Mounting style | Panel-mounted controller with integral keypad and liquid crystal display |
| Power connection | 24 VDC ±10% supply required |
| Ambient temperature limit | 0 to 55 °C (32 to 131 °F) operating range |
| Signal connections | Pump stroke sensor input (proximity switch); external start signal input; serial ports RS-422/RS-485 |
FAQ
What is the IWAKI SC-1?
The IWAKI SC-1 is a menu-driven pump controller that paces up to three Iwaki pneumatic drive bellows pumps simultaneously in chemical circulation and filtration systems.
Which pumps does the IWAKI SC-1 control?
It is designed for the Iwaki FF, FF-H, and FA series pneumatic drive bellows pumps; the FW and FW-H pumps are controlled by the companion SC-2 controller instead.
How many pumps can one IWAKI SC-1 control?
One SC-1 can control three pumps at the same time, providing coordinated stroke-rate control, monitoring, and alarm handling.
What control and alarm functions does the IWAKI SC-1 provide?
It provides constant speed control, overspeed control, leak alarm, and time-up alarm functions, and it continuously monitors and accumulates flow rate, pressure, stroke count, and total count.
What happens if the pump’s proximity switch fails?
The SC-1 includes a timer mode as standard equipment, so pump operation can continue in timer mode if the proximity switch fails.
Which communication interfaces does the IWAKI SC-1 offer?
It is equipped with RS-422 or RS-485 ports for integration into automated systems.
What power supply does the IWAKI SC-1 require?
It operates on a 24 VDC ±10% power supply.
What are the operating environment limits for the IWAKI SC-1?
It is rated for ambient temperatures from 0 to 55 °C (32 to 131 °F), with outer dimensions of 200 × 110 × 180 mm.