Description
Core Product Summary
The Kollmorgen S70601-SE is a fully digital servo amplifier from the S700 series, built on the 6 Arms current frame with the SERCOS expansion card installed in slot 1. The order code decodes directly: S7 identifies the S700 family, 06 the 6 Arms current rating, 0 the 208–480 V supply version, 1 the standard electrical/mechanical configuration, and -SE the SERCOS interface option. The unit belongs to the single-channel-STO hardware generation of the S700, with a Safe Stop function onboard rated SIL CL 2 per IEC 62061 and PLd, Category 3 per ISO 13849-1.
The drive connects to a grounded three-phase supply from 3×208 V to 3×480 V (±10%, 50/60 Hz), draws 4.5 kVA rated input power for S1 operation, and delivers 6 Arms continuous or 18 Arms peak output current for approximately 2 seconds. Onboard feedback evaluation covers resolver, encoder, AquadB, and ComCoder signals, and an integrated position controller closes position on the drive itself. EtherCAT and CANopen are onboard alongside RS-232 and a 24 V step/direction interface; with the SERCOS card fitted, the drive operates as a node in a fiber-optic SERCOS ring per IEC 61491, using F-SMA connectors for receive (X13) and transmit (X14). Commissioning uses the DriveGUI setup software over RS-232, or two front-panel keys and the 3-character LED display. The housing is a 70 mm-wide unit weighing 4.4 kg, mounting vertically at IP20 with a built-on fan.
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product family / type | S700 series digital servo amplifier (single-channel STO hardware), 6 Arms frame, SERCOS expansion card in slot 1 |
| Supply input | 3×208 V to 3×480 VAC (grounded supply, TN or TT with grounded neutral), ±10%, 50/60 Hz; single-phase supply possible for setup |
| Rated input power (S1) | 4.5 kVA |
| Rated DC bus link voltage | 260–900 VDC range (family); bus link can be paralleled between amplifiers |
| Rated output current | 6 Arms (±3%) |
| Peak output current | 18 Arms (approx. 2 s, ±3%) |
| Minimum motor inductance | Supply-voltage dependent; approx. 1.2 mH at 3×208 V up to approx. 2.7 mH at 3×480 V (per the rated data table) |
| Output current form factor | 1.01 (rated conditions, minimum load inductance) |
| Voltage rise speed (dU/dt) | 3.0 kV/µs at 3×208 V to 6.9 kV/µs at 3×480 V (measured without connected motor) |
| Current controller | Digital, space-vector PWM, 62.5 µs cycle, bandwidth > 1.2 kHz (up to 5 kHz) |
| Speed controller | Adjustable digital speed controller, 62.5 µs |
| Position controller | Integrated, 250 µs (optionally 125 µs) |
| Residual voltage drop at rated current | 4 V |
| Fieldbus (this configuration) | SERCOS expansion card in slot 1; fiber-optic ring per SERCOS standard IEC 61491; F-SMA connectors X13 (receive) and X14 (transmit) |
| Onboard interfaces | EtherCAT, CANopen, RS-232, 24 V step/direction interface |
| Feedback evaluation | Resolver, encoder, AquadB encoder, ComCoder |
| Functional safety | Safe Stop STO onboard, single channel: SIL CL 2 per IEC 62061, PLd Category 3 per ISO 13849-1 |
| Inputs / outputs | 2 programmable analog inputs (±10 V), 4 programmable digital inputs, 2 direction-selectable digital inputs/outputs, 1 Enable input, 1 STO Enable input, BTB/RTO relay output; separate 24 V supply input for digital outputs |
| Auxiliary supply | 24 VDC (−0/+15%), electrically isolated, internally fused; 1 A without brake, 3 A with brake; brake output 0.15 / 2 A |
| Programmability | Macro programming in IEC 61131 structured text; memory card slot for parameter records and firmware |
| Dimensions (H × W × D without connectors) | 345 mm × 70 mm × 243 mm (379 mm × 70 mm × 285 mm with connectors) |
| Weight | 4.4 kg |
| Enclosure protection | IP20 (IEC 60529) |
| Ambient temperature | 0 to +40 °C at rated data; +40 to +55 °C with 2.5 %/°C power derating |
| Humidity / altitude | Max. 85% relative humidity, no condensation; up to 1000 m unrestricted, 1000–2500 m with 1.5%/100 m derating |
| Mounting / cooling | Vertical mounting; built-on fan; sufficient forced ventilation in the cabinet required |
| Regen circuit | Internal brake resistor standard; external brake resistors optional; dynamic distribution of regenerative power between amplifiers on a common DC bus link |
| Approvals | CE conformance; GOST-R certificate covering S701…S724 servo amplifiers; safe electrical separation per IEC 61800-5-1, overvoltage category III |
Engineering Selection Highlights
- SERCOS card in slot 1 defines the system architecture — the -SE configuration makes this a SERCOS node in a fiber-optic ring; the controller side must be a SERCOS master, and only SERCOS-standard components per IEC 61491 should be used for the cabling. Machines built on EtherCAT or CANopen should order the standard onboard-communication configuration instead.
- 6 Arms continuous / 18 Arms peak (approx. 2 s) — a 3:1 peak ratio suited to axes with short, demanding acceleration cycles; match the motor’s continuous and peak ratings and the duty profile to this envelope.
- Supply-voltage-dependent constraints — the minimum motor inductance and the motor-side voltage rise rate both scale with the supply voltage (up to 6.9 kV/µs at 480 V); verify motor insulation and cable length against these values before commissioning.
- Onboard single-channel STO — the integrated Safe Stop meets SIL CL 2 / PLd Category 3, allowing the axis to be safely disabled without a separate contactor arrangement in suitable applications; suspended loads still require mechanical blocking.
- Wide feedback support without extra cards — resolver, encoder, AquadB, and ComCoder evaluation are onboard; cable limits are 100 m for resolver, 50 m for encoder, and 25 m for ComCoder connections with the specified cable types.
- Thermal limits are tighter than on predecessor platforms — full rating applies only to +40 °C ambient with 2.5 %/°C derating above, and the drive relies on cabinet forced ventilation in addition to its built-on fan.
- DC bus paralleling across drives — the brake circuit dynamically distributes regenerated power between several S700 amplifiers sharing one DC bus link, reducing external brake resistor needs in multi-axis cabinets.

S70601-SE

S70601-SE
System Compatibility & Integration Requirements
| Item / Dependency | Verified Compatibility or Requirement | Practical Note |
|---|---|---|
| Motion network | SERCOS expansion card (slot 1), fiber-optic ring per IEC 61491 | Use only SERCOS-standard components; receive fiber to X13, transmit fiber to X14, F-SMA connectors; transmission power is matched to cable length in the setup software |
| Mains supply | Grounded 3×208 V to 3×480 VAC TN/TT network, max. 42 kA symmetrical current rating | Other supply types require an isolating transformer; single-phase supply is possible for setup |
| Auxiliary control power | External 24 VDC supply, −0/+15% | 1 A without motor brake, 3 A with brake; digital outputs use a separate 24 V input |
| Feedback devices | Resolver (max. 100 m), encoder (max. 50 m), AquadB, ComCoder (max. 25 m) | Cable types and cross-sections per the manual’s connection data |
| Motors | Synchronous servomotors; S700 platform also supports linear motors, asynchronous motors, and DC motors | Check minimum motor inductance for the supply voltage used |
| Commissioning | DriveGUI setup software via RS-232; two front-panel keys and 3-character LED display without a PC | SERCOS parameters, including transmission power, are set on the SERCOS screen page |
| Functional safety | STO single channel, SIL CL 2 / PLd Category 3 | The STO function must be tested at initial startup and after any wiring or component change |
| Regen energy | Internal brake resistor standard; external optional; DC bus link paralleling with dynamic regen distribution | Permitted for several amplifiers of the same series on a common bus |
| Macro programming | IEC 61131 structured text, 128 kByte memory | Cycle times from 62.5 µs selectable |
| Expansion slots | Slot 1 occupied by SERCOS card (this configuration); slots 2 and 3 can hold, e.g., controlled-fan (F2) and PosI/O cards | Slot 1 cards can be combined with the F2 option in slot 2; other slot combinations are not possible |
Dimensions, Mounting & Connection Notes
| Item | Data |
|---|---|
| Height × Width × Depth | 345 × 70 × 243 mm without connectors; 379 × 70 × 285 mm with connectors |
| Weight | 4.4 kg |
| Mounting | Vertical mounting position in the cabinet; built-on fan; keep ventilation unobstructed and provide forced ventilation in the switchgear cabinet |
| Power connections | Power-Combicon connectors (X0, X8, X9); recommended tightening torque 0.7–0.8 Nm |
| Control connections | Mini-Combicon connectors X3A/B/C for control signals; X4A/B for auxiliary voltage |
| Feedback connectors | Resolver via 9-pin Sub-D socket (X2); encoder via 15-pin Sub-D socket (X1); PC/CAN via 9-pin Sub-D plug (X6); encoder emulation ROD/SSI optional via 9-pin Sub-D plug (X5) |
| SERCOS connection | Fiber-optic cables with F-SMA connectors: receive to X13, transmit to X14 |
| Grounding | Grounding bolt, 3.5 Nm; all shielding connections made directly at the amplifier |
| External fusing (S706) | AC supply feed 16 AT (15 A) time-delay; 24 V feed 10 AT; brake resistor 10 AT |
| Conductor cross-sections (S701–S706) | AC connection and DC bus link 1.5 mm² (14 AWG); motor cable 1–1.5 mm² (14 AWG); feedback cables as specified per interface |
| Motor cable limits | Max. 25 m without choke; 25–50 m with a 3YL/3YLN motor choke wired close to the amplifier |
| Environmental limits | 0 to +40 °C at rated data (2.5 %/°C derating to +55 °C); max. 85% RH non-condensing; up to 1000 m altitude unrestricted (1.5%/100 m derating to 2500 m); pollution level 2 per IEC 60664-1 |
Detailed Product Overview
The S700 generation sits between Kollmorgen’s compact SERVOSTAR platforms and the higher-current S700 variants, covering 1.5 A to 24 A frames in two housing widths. The S70601-SE is the 6 Arms, 70 mm-wide member of that range, and its order code is worth reading carefully because every position carries engineering meaning. After the family and current designation, the digit “0” fixes the 208–480 V supply version, the digit “1” means no electrical/mechanical option (no extended peak current, no coated PCBs), and “-SE” places the SERCOS expansion card in slot 1. An S70601 with a different slot-1 card — PROFIBUS, DeviceNet, SynqNet, or the -2CAN- module — is a different order code even though the power stage is identical; the fieldbus choice must match the machine’s controller, not just the axis size.
Electrically, the drive accepts a grounded three-phase supply across the full 208–480 V span. The rated input power for S1 operation is 4.5 kVA at this frame, and the IGBT output stage delivers 6 Arms continuous with 18 Arms peak for roughly two seconds. Two supply-dependent figures deserve attention during motor selection. First, the minimum permissible motor inductance rises with the supply voltage — from roughly 1.2 mH on a 208 V network to around 2.7 mH at 480 V — so a winding that is acceptable on a 230 V supply can fall below the limit after a supply change. Second, the motor-side voltage rise rate reaches 6.9 kV/µs at 480 V input, which matters for motor winding insulation stress and for EMC layout of the motor cable; the manual requires a motor choke for cable lengths between 25 and 50 m.
The control chain is entirely digital: a current controller with space-vector PWM on a 62.5 µs cycle, an adjustable speed controller on the same cycle, and an integrated position controller at 250 µs (125 µs optional). The output current form factor of 1.01 under rated conditions keeps distortion-induced motor heating low, and the residual voltage drop of 4 V at rated current preserves torque margin on longer motor runs. Feedback evaluation is unusually broad for the frame size: resolver, incremental encoder, AquadB, and ComCoder inputs are all onboard, with encoder emulation output available as an option.
The SERCOS card defines how this particular unit is used. It inserts the drive into a fiber-optic ring per IEC 61491, with F-SMA connectors for the receive and transmit fibers and three status LEDs that report received and transmitted telegrams plus communication errors. Because SERCOS communication quality depends on optical power matching, the drive’s transmitting power is set in the DriveGUI software according to the actual cable length — a commissioning step that fixed-copper fieldbuses do not require. The protocol functions themselves follow the SERCOS IDN structure documented separately by the manufacturer.
Safety and installation follow the platform conventions. The onboard STO function provides a single-channel safe stop rated SIL CL 2 and PLd Category 3, tested at startup and after any wiring change; the drive cannot hold suspended loads in STO, so mechanical blocking remains mandatory for vertical axes. The unit mounts vertically, weighs 4.4 kg, and measures 345 × 70 × 243 mm without connectors. Its full rating applies only to +40 °C ambient — tighter than many drives in this class — with 2.5 %/°C derating above that and a built-on fan that presupposes cabinet forced ventilation. External fusing for this frame is a 16 AT time-delay fuse on the AC feed, and the 24 V auxiliary supply is internally fused with separate protection for the brake and fan circuits. With the memory card slot, macro programming in IEC 61131 structured text, and access to parameters over EtherCAT or CANopen as well, the platform supports both straightforward single-axis setups and coordinated multi-axis machines built around the SERCOS ring.
Applications & System Role
In the machine architecture, the S70601-SE operates as a networked single-axis servo amplifier within a SERCOS motion system: the SERCOS master coordinates the axes over the fiber-optic ring, while the drive closes its current, speed, and position loops locally and converts the cyclic telegrams into regulated motor current.
Fit scenarios that follow from the verified capability profile:
- Axes on SERCOS-based motion systems where deterministic, cyclic fiber-optic communication between one controller and multiple drives is the established machine architecture.
- Single axes with 6 Arms continuous demand and short bursts to 18 Arms — positioning, feed, and handling axes with moderate continuous torque and dynamic acceleration cycles.
- Safety-conscious machine designs where the onboard single-channel STO (SIL CL 2 / PLd Cat. 3) allows a standards-based safe stop without external contactor hardware in the drive power path.
- Applications with mixed feedback situations — resolver, encoder, AquadB, or ComCoder — since all four are evaluated onboard without an expansion card.
- Multi-axis cabinets where several S700 drives share a common DC bus link and distribute regenerative braking energy dynamically.
The practical boundaries to respect are the +40 °C full-rating ambient, the supply-voltage-dependent minimum motor inductance and dU/dt, the 42 kA maximum symmetrical supply rating, and the requirement for a grounded TN/TT network or an isolating transformer.
FAQ
What is the Kollmorgen S70601-SE?
It is an S700-series digital servo amplifier in the 6 Arms current frame, fitted with the SERCOS expansion card in slot 1 and equipped with onboard single-channel STO safety functionality.
What does the order code mean?
S7 identifies the S700 family, 06 the 6 Arms current rating, 0 the 208–480 V supply version, 1 the standard electrical/mechanical configuration (no options), and -SE the SERCOS expansion card in slot 1.
What are its current and power ratings?
Rated output current is 6 Arms (±3%) with 18 Arms peak for approximately 2 seconds; rated input power for S1 operation is 4.5 kVA.
What supply does it need?
A grounded three-phase supply from 3×208 V to 3×480 VAC (±10%, 50/60 Hz), TN or TT network with grounded neutral and a maximum 42 kA symmetrical current rating; other supply types require an isolating transformer. Single-phase supply is possible for setup.
How does the SERCOS interface connect?
Through the SERCOS expansion card using fiber-optic cables in a ring structure per IEC 61491 — receive data to connector X13 and transmit data to X14, both F-SMA; only SERCOS-standard components should be used.
Which feedback devices does it support?
Resolver, encoder, AquadB, and ComCoder signals are evaluated onboard, with maximum cable lengths of 100 m (resolver), 50 m (encoder), and 25 m (ComCoder) using the specified cable types.
What safety function is built in?
A single-channel Safe Stop (STO) rated SIL CL 2 per IEC 62061 and PLd, Category 3 per ISO 13849-1; the function must be tested at initial startup and after any change to the drive wiring.
How is the drive commissioned?
With the DriveGUI setup software over the RS-232 interface, or directly on the unit with two keys and the 3-character LED display; SERCOS transmission power is matched to cable length in the software.
What installation limits apply?
Vertical mounting at IP20 with built-on fan, 0 to +40 °C at rated data (2.5 %/°C derating to +55 °C), up to 1000 m altitude unrestricted, and maximum 85% relative humidity without condensation.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626