Description
3. Key Technical Specifications
- Roll / Pitch accuracy: 0.02° RMS (static, ±5° amplitude)
- Dynamic roll / pitch accuracy: approx. 0.005° (1-sigma)
- Heave accuracy (real-time): 5 cm or 5 % (whichever is greater), up to 25 s period
- Heave delayed: higher accuracy options available (typically 1 cm / 1 %)
- Angular rate range: ±149 °/s typical
- Output variables: Roll, pitch, yaw (with external heading), heave, surge, sway, accelerations, angular rates
- Output interfaces: RS-232, RS-422, Ethernet
- Data rate: Up to 200 Hz
- Lever-arm compensation: Two individually configurable monitoring points
- Sensors: Three high-accuracy accelerometers + three Kongsberg MRG MEMS gyros
- Power supply: 10–36 V DC (24 V DC recommended)
- Size / weight: Compact (approx. Ø105 × 140 mm, ~2.2 kg)
- Mounting: No orientation limitation
- Features: PFreeHeave algorithms for long-period heave, external speed/heading input support, Windows configuration software
- Note: Exact performance, firmware version, and any subsea or special options must be verified against the unit calibration certificate and serial number.
4. Product Introduction
The Kongsberg MRU 5 is a fifth-generation Motion Reference Unit designed for high-precision measurement of vessel and platform motion. It delivers accurate roll, pitch, and heave data for demanding marine applications.
Engineers use the MRU 5 for motion compensation of multibeam echo sounders, offshore cranes, hydroacoustic positioning systems, dynamic positioning, and structural monitoring. Solid-state sensors with no moving parts provide high reliability and long-term stability in surface and subsea environments.

MRU 5

MRU 5
5. Troubleshooting Quick Reference
| Symptom | Possible Cause | Relevance to this Part | Quick Check Method | Recommendation |
|---|---|---|---|---|
| No data output | Power or communication fault | ✅ High | Check 10–36 V DC supply and cable connections | Verify power and interface wiring; replace unit if power is present and no output |
| Poor roll/pitch accuracy | Incorrect mounting or lever-arm settings | ✅ High | Verify installation orientation and lever-arm values in software | Reconfigure mounting parameters and lever arms |
| Unstable heave | Long-period waves or filter settings | ✅ Medium | Review PFreeHeave settings and external speed input | Adjust heave algorithms and enable external aiding if available |
| Communication failure | Wrong protocol, baud rate, or IP settings | ✅ High | Check configuration software settings and cable type | Match protocol (RS-232/422/Ethernet) and parameters |
| Unit not recognized | Firmware or software version mismatch | ✅ Medium | Confirm serial number and software compatibility | Update configuration software or contact support |
| Calibration warning | Sensor drift or environmental shock | ✅ Medium | Review calibration certificate and self-test status | Return for recalibration if performance is out of specification |
If the issue cannot be resolved, photograph the unit (including labels and connectors), note the serial number, and contact technical support with installation details.
6. Frequently Asked Questions (FAQ)
Q: What does the Kongsberg MRU 5 measure?
A: It provides high-accuracy roll, pitch, heave, and related motion data (surge, sway, accelerations, angular rates) for marine and offshore applications.
Q: What is the roll/pitch accuracy?
A: 0.02° RMS static accuracy within ±5° amplitude. Dynamic performance is even better (approximately 0.005° 1-sigma).
Q: Which interfaces are available?
A: RS-232, RS-422, and Ethernet. Multiple protocols are selectable via the configuration software.
Q: Can it be used on subsea vehicles?
A: Yes. The MRU 5 maintains specified accuracy on surface vessels and subsea vehicles. Special subsea housings are available for deeper applications.
Q: Does it require external aiding?
A: External speed and heading inputs improve dynamic performance but are not mandatory for basic operation.
Q: Is a calibration certificate included?
A: Yes. Each MRU 5 is delivered with a calibration certificate.
Q: What condition and warranty do you offer?
A: We supply New Original / New Surplus stock. Units are inspected for basic functionality. Standard coverage is a 1-year warranty against defects (Kongsberg typically offers a 2-year manufacturer warranty on new units). Always provide the complete model MRU 5 and serial number when ordering or requesting support.

WhatsApp: +86 16626708626
Email:
Phone: +86 16626708626